Hilti
Hilti Cordless Vacuums Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
BAT-HOT
Battery temperature icon appears; vacuum will not run until cooled
Battery Overtemperature Protection
BAT-LOW
Battery icon flashes and vacuum stops; no other error code shown
Low Battery Voltage Cutoff
E1
Cordless vacuum will not power on; display briefly flashes then turns off
Undervoltage / Battery Protection Triggered
E10
Vacuum LEDs flash in a pattern corresponding to E10; tool unresponsive to trigger
User Interface / Switch Circuit Fault
E2
Cordless vacuum stops shortly after starting; display shows E2 or two-blink fault pattern
Overcurrent / Motor Overload Protection
E3
Vacuum shuts down after a few seconds of operation; error E3 or triple-blink LED pattern
Motor Overtemperature Protection
E4
Vacuum does not start; LEDs indicate fault E4; battery works fine on other Hilti tools
Electronics / Control PCB Failure
E5
Vacuum runs only at low power or surges; error E5 appears intermittently
Motor Speed Control / Hall Sensor Fault
E6
Vacuum will not start with certain batteries; E6 or battery symbol flashes
Battery Communication / Compatibility Error
E7
Vacuum stops and shows E7 when used in very dusty environments
Dust Sensor / Filter Monitoring Fault (if equipped)
E8
Vacuum will not start; E8 displayed after suspected liquid ingress
Moisture / Short-Circuit Protection
E9
Vacuum runs but then shuts off with E9 when using high-power mode
Overload / Power Stage Fault
FILTER
Filter warning icon illuminated; suction reduced
Filter Clogged / Restricted Airflow
LED-BLINK-2
Status LED blinks twice repeatedly; vacuum does not start
Short Circuit Detected at Motor Output
LED-BLINK-3
Status LED blinks three times repeatedly; vacuum starts then stops
Motor Stall / Rotor Blocked
Symptom
Battery drains unusually fast when using the vacuum
Excessive Current Draw / Reduced Battery Capacity
Symptom
Excessive vibration felt in handle and housing while vacuum is running
Fan Imbalance / Loose Components
Symptom
Hose keeps disconnecting from vacuum or tools during use
Worn Hose Coupling / Locking Mechanism
Symptom
On/off switch feels loose or does not click; vacuum only starts intermittently
Mechanical Switch Wear
Symptom
Static shocks felt when touching vacuum or hose during operation
Static Electricity Build-Up
Symptom
Strong burning smell from vacuum during or after use
Motor Overheating / Electrical Insulation Breakdown
Symptom
Vacuum body or handle becomes excessively hot to the touch during normal use
Overheating Due to Restricted Cooling
Symptom
Vacuum cannot be mounted or clipped to Hilti tools or accessories as before
Broken Mounting Clip / Interface
Symptom
Vacuum does not turn on at all; no lights, no sound, even with charged battery
Complete Power Loss
Symptom
Vacuum emits unusual rattling noise from inside container
Loose Internal Components / Debris
Symptom
Vacuum leaves fine dust haze in the air; filtration seems poor
Insufficient Filtration / Wrong Filter Type
Symptom
Vacuum makes loud grinding or screeching noise during operation
Worn Motor Bearings / Fan Damage
Symptom
Vacuum performance drops significantly when using long hose or multiple accessories
Excessive System Resistance
Symptom
Vacuum runs but dust escapes from around the lid or filter area
Seal Failure / Filter Bypass
Symptom
Vacuum runs but has very weak suction even with clean filter
Airflow Loss / Internal Leak
Symptom
Vacuum runs only at one speed; power selector has no effect
Speed Control Failure
Symptom
Vacuum shuts off randomly during use without any error indication
Intermittent Power Loss
Symptom
Vacuum trigger or switch area gets dusty inside clear cover (if equipped)
Ingress of Dust into Control Area
Symptom
Vacuum will not latch or close properly; lid pops open during use
Container Latch / Hinge Failure
Symptom
Vacuum will not stand or store properly; base feels unstable
Damaged Base / Support Feet
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| BAT-HOT |
Battery temperature icon appears; vacuum will not run until cooled
|
Battery Overtemperature Protection | View Details |
| BAT-LOW |
Battery icon flashes and vacuum stops; no other error code shown
|
Low Battery Voltage Cutoff | View Details |
| E1 |
Cordless vacuum will not power on; display briefly flashes then turns off
|
Undervoltage / Battery Protection Triggered | View Details |
| E10 |
Vacuum LEDs flash in a pattern corresponding to E10; tool unresponsive to trigger
|
User Interface / Switch Circuit Fault | View Details |
| E2 |
Cordless vacuum stops shortly after starting; display shows E2 or two-blink fault pattern
|
Overcurrent / Motor Overload Protection | View Details |
| E3 |
Vacuum shuts down after a few seconds of operation; error E3 or triple-blink LED pattern
|
Motor Overtemperature Protection | View Details |
| E4 |
Vacuum does not start; LEDs indicate fault E4; battery works fine on other Hilti tools
|
Electronics / Control PCB Failure | View Details |
| E5 |
Vacuum runs only at low power or surges; error E5 appears intermittently
|
Motor Speed Control / Hall Sensor Fault | View Details |
| E6 |
Vacuum will not start with certain batteries; E6 or battery symbol flashes
|
Battery Communication / Compatibility Error | View Details |
| E7 |
Vacuum stops and shows E7 when used in very dusty environments
|
Dust Sensor / Filter Monitoring Fault (if equipped) | View Details |
| E8 |
Vacuum will not start; E8 displayed after suspected liquid ingress
|
Moisture / Short-Circuit Protection | View Details |
| E9 |
Vacuum runs but then shuts off with E9 when using high-power mode
|
Overload / Power Stage Fault | View Details |
| FILTER |
Filter warning icon illuminated; suction reduced
|
Filter Clogged / Restricted Airflow | View Details |
| LED-BLINK-2 |
Status LED blinks twice repeatedly; vacuum does not start
|
Short Circuit Detected at Motor Output | View Details |
| LED-BLINK-3 |
Status LED blinks three times repeatedly; vacuum starts then stops
|
Motor Stall / Rotor Blocked | View Details |
| – |
Battery drains unusually fast when using the vacuum
|
Excessive Current Draw / Reduced Battery Capacity | View Details |
| – |
Excessive vibration felt in handle and housing while vacuum is running
|
Fan Imbalance / Loose Components | View Details |
| – |
Hose keeps disconnecting from vacuum or tools during use
|
Worn Hose Coupling / Locking Mechanism | View Details |
| – |
On/off switch feels loose or does not click; vacuum only starts intermittently
|
Mechanical Switch Wear | View Details |
| – |
Static shocks felt when touching vacuum or hose during operation
|
Static Electricity Build-Up | View Details |
| – |
Strong burning smell from vacuum during or after use
|
Motor Overheating / Electrical Insulation Breakdown | View Details |
| – |
Vacuum body or handle becomes excessively hot to the touch during normal use
|
Overheating Due to Restricted Cooling | View Details |
| – |
Vacuum cannot be mounted or clipped to Hilti tools or accessories as before
|
Broken Mounting Clip / Interface | View Details |
| – |
Vacuum does not turn on at all; no lights, no sound, even with charged battery
|
Complete Power Loss | View Details |
| – |
Vacuum emits unusual rattling noise from inside container
|
Loose Internal Components / Debris | View Details |
| – |
Vacuum leaves fine dust haze in the air; filtration seems poor
|
Insufficient Filtration / Wrong Filter Type | View Details |
| – |
Vacuum makes loud grinding or screeching noise during operation
|
Worn Motor Bearings / Fan Damage | View Details |
| – |
Vacuum performance drops significantly when using long hose or multiple accessories
|
Excessive System Resistance | View Details |
| – |
Vacuum runs but dust escapes from around the lid or filter area
|
Seal Failure / Filter Bypass | View Details |
| – |
Vacuum runs but has very weak suction even with clean filter
|
Airflow Loss / Internal Leak | View Details |
| – |
Vacuum runs only at one speed; power selector has no effect
|
Speed Control Failure | View Details |
| – |
Vacuum shuts off randomly during use without any error indication
|
Intermittent Power Loss | View Details |
| – |
Vacuum trigger or switch area gets dusty inside clear cover (if equipped)
|
Ingress of Dust into Control Area | View Details |
| – |
Vacuum will not latch or close properly; lid pops open during use
|
Container Latch / Hinge Failure | View Details |
| – |
Vacuum will not stand or store properly; base feels unstable
|
Damaged Base / Support Feet | View Details |
No matching codes found
Advertisements