Stanley

Stanley Garage Door Openers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
1 FLASH
Opener will not run; wall button and remotes do nothing; courtesy light may be on; diagnostic LED on logic board flashes once repeatedly.
Photo Eye Obstruction or Misalignment
2 FLASHES
Door will not close from remote; opener clicks but reverses or will not move; diagnostic LED on logic board flashes twice repeatedly.
Safety Sensor Circuit Open or Shorted
3 FLASHES
Opener runs briefly then stops and reverses; door may move a few inches and return to open; diagnostic LED flashes three times repeatedly.
Down Travel Limit or Force Error
4 FLASHES
Opener will not move the door; motor hums briefly then stops; diagnostic LED flashes four times repeatedly.
Motor Overload or Stalled Motor
5 FLASHES
Opener stops mid-travel and reverses; sometimes runs only a short distance; diagnostic LED flashes five times repeatedly.
Up Travel Limit or Force Error
6 FLASHES
Opener will not respond to remote controls; wall button may still operate the door; diagnostic LED flashes six times repeatedly.
Radio Receiver or Antenna Fault
7 FLASHES
Opener does not respond to wall button; remotes may still work; diagnostic LED flashes seven times repeatedly.
Wall Control Circuit Fault
8 FLASHES
Opener runs but courtesy light does not turn on, or stays on constantly; diagnostic LED flashes eight times repeatedly.
Courtesy Light Circuit Fault
9 FLASHES
Opener will not run; diagnostic LED flashes nine times repeatedly; sometimes accompanied by a burning smell previously.
Logic Board Power Supply Fault
BLINKING SAFETY SENSOR LED
One of the Stanley safety sensors has a blinking LED while the other is solid or off; door will not close from remote unless wall button is held.
Safety Sensor Misalignment or Polarity Error
REMOTE LED FLASHES, NO DOOR MOVEMENT
Remote control LED lights when pressed, but the Stanley opener does not run; no change in opener lights or sounds.
Lost Remote Programming or Incompatible Remote
STEADY LED, NO RESPONSE
Diagnostic LED on the Stanley opener is solid (no flashing), but the opener does not respond to wall button or remotes.
Microcontroller or Logic Lockup
WALL CONSOLE LED FLASH PATTERN
Stanley multi-function wall console LED flashes in a repeating pattern and the door will not move when the main button is pressed.
Wall Console Lock or Vacation Mode Enabled
Symptom
Garage door opener beeps or clicks but does not move the door; no obvious motor sound.
Relay Activation Without Motor Start
Symptom
Garage door opener belt appears frayed or cracked and makes squealing noises.
Worn Drive Belt
Symptom
Garage door opener chain slaps the rail loudly during starting and stopping.
Excessive Chain Slack
Symptom
Garage door opener does not lock the door; you can easily lift the door by hand when it is closed and connected.
Backdrive or Lack of Mechanical Lock
Symptom
Garage door opener does not respond after a power outage; no lights or sounds from the unit.
No AC Power or Blown Internal Fuse
Symptom
Garage door opener keypad mounted outside does not operate the door, but remotes and wall button work.
Wireless Keypad Failure or Programming Loss
Symptom
Garage door opener light does not turn on when the door operates, but the opener otherwise works normally.
Courtesy Light Inoperative
Symptom
Garage door opener light stays on continuously and never turns off after the delay.
Stuck Courtesy Light Relay
Symptom
Garage door opener operates intermittently; sometimes stops mid-cycle and then works again after a few minutes.
Thermal Overload or Intermittent Electrical Connection
Symptom
Garage door opener operates normally but there is a noticeable electrical buzzing or humming from the unit when idle.
Transformer Hum or Vibrating Components
Symptom
Garage door opener operates, but the door jerks or shudders at the start or end of travel.
Improper Travel Limit Position or Loose Door Hardware
Symptom
Garage door opener operates, but the door moves very slowly or struggles, especially in cold weather.
High Friction or Weak Assist from Springs
Symptom
Garage door opener rail flexes excessively or moves during operation, causing vibration and noise.
Inadequate Support or Loose Mounting
Symptom
Garage door opens by itself randomly without anyone pressing a button.
Unintended Activation from Interference or Short
Symptom
Garage door reverses immediately after hitting the floor; opens back up fully instead of staying closed.
Down Force Too Low or Travel Overrun
Symptom
Garage door starts to close then reverses when it is about halfway down, with no visible obstruction.
Door Binding or Track Obstruction Mid-Travel
Symptom
Garage door will not close from remote but will close if you press and hold the wall button continuously.
Safety Reversal System Override Required
Symptom
Garage door will not open fully; stops short of the fully open position, leaving the door partially down.
Insufficient Up Travel or Weak Lift
Symptom
Opener emits a burning smell or visible smoke during or after operation.
Electrical Overheating or Component Failure
Symptom
Opener hums but chain or belt does not move; door does not open or close.
Stripped Drive Gear or Sprocket Failure
Symptom
Opener light flashes but motor does not run when you try to operate the door.
Safety Lockout or Obstruction Detected
Symptom
Opener motor runs but the garage door does not move; chain or belt moves along the rail but the door stays put.
Disengaged Trolley or Broken Door Arm Connection
Symptom
Opener runs but makes loud grinding or rattling noises during operation.
Worn Drive Components or Loose Hardware
Symptom
Opener works from wall button but has very poor remote range; remote only works when standing directly under the opener.
Weak Radio Reception
Advertisements