Pioneer

Pioneer Air Conditioners Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E0
Indoor unit displays E0 and will not respond to remote commands or buttons
EEPROM Parameter Error / Indoor PCB Configuration Fault
E1
Indoor unit shows E1 and stops cooling or heating shortly after startup
High-Pressure Protection / Refrigerant System Overpressure
E2
Indoor unit displays E2 and stops cooling; may run fan only
Indoor Evaporator Coil Freeze Protection / Low Temperature Protection
E3
Indoor unit shows E3 and stops; outdoor unit may shut down shortly after starting
Low-Pressure Protection / Refrigerant Undercharge or Flow Restriction
E4
Indoor unit displays E4 and shuts down during heating mode
Defrost Protection / Outdoor Coil Overheat or Frost Fault
E5
Indoor unit shows E5 and will not start compressor; fan may still run
Overcurrent Protection / Compressor Overload
E6
Indoor unit displays E6 and does not cool or heat; outdoor unit may not start
Communication Failure Between Indoor and Outdoor Units
E7
Indoor unit shows E7 and system will not operate in one or more modes
Mode Conflict / Indoor-Outdoor Mode Mismatch
E8
Indoor unit displays E8 and may shut down unexpectedly, especially in high load conditions
Overload Protection / Indoor Fan or System Overload
E9
Indoor unit shows E9 and may leak water or stop cooling
Water Overflow Protection / Drainage Fault
F0
Indoor unit displays F0 and system does not cool properly
Refrigerant Undercharge / Low Refrigerant Protection
F1
Indoor unit shows F1 and may run fan only with no cooling
Indoor Ambient Temperature Sensor (Room Sensor) Fault
F2
Indoor unit displays F2 and may stop cooling or heating
Indoor Evaporator Coil Temperature Sensor Fault
F3
Indoor unit shows F3, often during heating mode
Outdoor Ambient Temperature Sensor Fault
F4
Indoor unit displays F4 and system may not heat properly
Outdoor Condenser/Coil Temperature Sensor Fault
F5
Indoor unit shows F5 and may stop during heating defrost cycles
Outdoor Discharge Pipe Temperature Sensor Fault
F6
Indoor unit displays F6 and cooling capacity is reduced
Indoor Fan Speed Out of Control / Feedback Error
F7
Indoor unit shows F7 and outdoor unit may not respond
Outdoor Fan Speed Abnormal / Feedback Error
F8
Indoor unit displays F8 and system may shut down under heavy load
Inverter Module Overheat / IPM Overtemperature Protection
F9
Indoor unit shows F9 and may not maintain set temperature accurately
Indoor Auxiliary Temperature Sensor Fault (e.g., Pipe or Mid-Coil Sensor)
H0
Indoor unit displays H0 and system may not start or may run in limited mode
Indoor EEPROM or Configuration Mismatch
H1
Indoor unit shows H1 and no warm air is produced at the start of heating
Defrost or Preheat Mode Indication (Not Always a Fault)
H2
Indoor unit displays H2 and heating performance is poor or intermittent
Compressor Overheat Protection in Heating
H3
Indoor unit shows H3 and system shuts down under heavy cooling load
Compressor Overload / Overcurrent Protection
H4
Indoor unit displays H4 and may not respond to mode changes
Indoor-Outdoor Mismatch or Capacity Code Error
H5
Indoor unit shows H5 and system may not start or may shut down quickly
IPM (Inverter Power Module) Protection / Drive Fault
H6
Indoor unit displays H6 and outdoor fan does not run
Outdoor Fan Motor Lock or Feedback Fault
H7
Indoor unit shows H7 and compressor does not start
Compressor Position or Phase Error (Inverter Models)
H8
Indoor unit displays H8 and system may run at reduced capacity
Indoor Fan Motor Overload or Stall
H9
Indoor unit shows H9 and room temperature control is erratic
Remote Controller or I-Feel Sensor Fault (on models with built-in sensor in remote)
Symptom
Breaker trips whenever the air conditioner starts or shortly after
Overcurrent / Electrical Short
Symptom
Indoor unit and outdoor unit both run but cooling is weak; supply air only slightly cooler than room
Reduced Cooling Capacity / Refrigerant or Airflow Problem
Symptom
Indoor unit blows warm air in COOL mode or cool air in HEAT mode
Reversing Valve or Mode Control Failure
Symptom
Indoor unit displays lights but airflow is very weak even on high fan setting
Restricted Indoor Airflow
Symptom
Indoor unit does not power on at all; no lights or display
No Power to Indoor Unit
Symptom
Indoor unit emits clicking or popping noises during operation or when starting/stopping
Thermal Expansion and Plastic Casing Noise
Symptom
Indoor unit fan runs but compressor and outdoor fan start and stop repeatedly within seconds
Unstable Inverter Operation / DC Bus or Control Fault
Symptom
Indoor unit powers on but will not respond to remote control commands
IR Receiver or Remote Control Failure
Symptom
Indoor unit produces a musty or moldy odor when starting
Biological Growth on Evaporator Coil and Drain Pan
Symptom
Indoor unit runs but no cooling; air is room temperature and outdoor unit does not start
Outdoor Unit Not Energizing / Control or Power Supply Fault
Symptom
Indoor unit vibrates excessively or makes knocking sounds, especially at high fan speed
Indoor Vibration / Fan Imbalance
Symptom
Outdoor unit makes loud rattling, buzzing, or grinding noises during operation
Outdoor Mechanical Noise / Fan or Compressor Issue
Symptom
System frequently short cycles (turns on and off every few minutes) without reaching set temperature
Short Cycling / Control or Capacity Issue
Symptom
Water dripping from the front of the indoor unit or down the wall
Indoor Unit Water Leak / Condensate Drainage Problem