F.00
Water heater does not start; display shows F.00 and burner never ignites
Flow Temperature Sensor Open Circuit
F.01
Water heater locks out with F.01; unit attempts to start but shuts down quickly
Flow Temperature Sensor Short Circuit
F.10
Display shows F.10; water heater will not fire when hot water is demanded
Return Temperature Sensor Open Circuit
F.11
F.11 displayed; unit may start briefly then shut down, or not start at all
Return Temperature Sensor Short Circuit
F.20
Water heater locks out with F.20; unit overheats and shuts down, sometimes with very hot water at outlets
Safety Temperature Limiter / Overheat Protection Activated
F.22
F.22 displayed; water heater will not fire, sometimes accompanied by gurgling noises
Dry Fire / Low Water Pressure / No Water in Heat Exchanger
F.23
F.23 error; unit may start then quickly shut down, often with noisy operation
Flow/Return Temperature Difference Too High (Low Circulation)
F.24
F.24 displayed; rapid temperature rise detected, unit shuts down quickly
Rapid Temperature Rise / Low Water Content
F.28
F.28 ignition fault; water heater attempts to ignite several times but fails, no stable flame
Ignition Failure / No Flame Establishment
F.29
F.29 flame loss; burner lights briefly then goes out, unit locks out
Flame Detection Failure / Flame Loss During Operation
F.32
F.32 displayed; fan does not run or runs erratically, no ignition
Fan Motor Fault / Fan Speed Signal Error
F.33
F.33 air/flue fault; appliance does not ignite or shuts down shortly after starting
Air Pressure Switch / Flue Gas Path Fault
F.36
F.36 flue gas recirculation; appliance shuts down shortly after ignition
Flue Gas Recirculation / Flue Blockage
F.61
F.61 gas valve fault; appliance will not ignite
Gas Valve Control Fault
F.62
F.62 gas valve closing fault; appliance may continue burning briefly after demand ends or lock out
Delayed Gas Valve Closure / Gas Valve Sticking
F.64
F.64 electronics temperature fault; appliance may shut down intermittently
Electronics Overtemperature / Sensor Fault
F.65
F.65 electronics fault; appliance locked out, no operation
Electronics Overtemperature / PCB Protection Triggered
F.67
F.67 flame signal error; appliance locks out after failed ignition attempts
Flame Signal Processing Fault
F.70
F.70 displayed after PCB replacement or power-up; appliance may not operate correctly
Configuration / Appliance Type Mismatch
F.71
F.71 temperature sensor plausibility error; appliance may cycle rapidly or shut down
Flow Temperature Sensor Plausibility Fault
F.72
F.72 flow/return sensor mismatch; appliance may not modulate correctly
Flow and Return Temperature Sensor Difference Implausible
F.75
F.75 pump/flow detection fault; appliance does not start heating cycle
No Pressure Change Detected on Pump Start (where fitted)
F.76
F.76 primary heat exchanger overheat; appliance locked out
Primary Heat Exchanger Thermal Fuse Triggered
F.83
F.83 temperature rise fault; appliance may start but quickly shut down
Insufficient Water Flow / Incorrect Temperature Rise
F.84
F.84 flow sensor plausibility fault; temperature control unstable
Flow Sensor / NTC Correlation Error
F.85
F.85 multiple flow sensor fault; appliance may not respond correctly to demand
Flow Sensor Signal Error / Multiple Sensors Conflict
F.91
F.91 gas type / combustion fault; appliance may run roughly or shut down
Gas Type / Combustion Configuration Error
Symptom
Water heater delivers hot water initially, then temperature quickly drops to lukewarm or cold
Intermittent DHW Temperature / Flow Modulation Fault
Symptom
Water heater emits a burning smell or plastic smell during operation
Overheating Electrical Component / Insulation Damage
Symptom
Water heater frequently cycles on and off with short burner run times
Short Cycling / Control Instability
Symptom
Water heater is leaking from the condensate pipe or trap area
Condensate Drain Leak / Blockage
Symptom
Water heater is leaking water from the bottom of the casing
Internal Water Leak
Symptom
Water heater is unusually noisy, with humming or grinding sounds during operation
Mechanical Noise from Pump, Fan, or Burner
Symptom
Water heater makes loud banging or knocking noises when heating water
Kettling / Boiling in Heat Exchanger
Symptom
Water heater produces no hot water at any tap, but display shows no error code
No DHW Production Without Fault Code
Symptom
Water heater temperature fluctuates between very hot and cold during a shower
DHW Temperature Instability
Symptom
Water heater trips the electrical breaker or RCD when it starts
Electrical Short or Earth Leakage
Symptom
Water heater vibrates excessively or rattles when the burner is running
Vibration / Resonance Fault
Symptom
Water heater will not power on at all; display is blank
No Power / Dead Appliance
Symptom
Water heater’s flue terminal shows signs of staining or water dripping
Condensate / Flue Gas Discharge Issue
Symptom
Water heater’s hot water is not hot enough even at maximum setting
Underheating DHW / Insufficient Output
Symptom
Water heater’s hot water is too hot even at low temperature setting
Overheating DHW / Temperature Control Fault
Symptom
Water heater’s hot water output is lower than expected (reduced flow rate)
Reduced DHW Flow / Hydraulic Restriction