Trane Air Conditioners Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E0
Trane air conditioner control board display shows E0 and system will not start cooling or heating.
Communication Fault Between Indoor and Outdoor Unit
E1
Trane air conditioner displays E1 and shuts down or will not start; may attempt to start and then stop quickly.
High-Pressure Protection Trip
E2
Trane air conditioner shows E2 and may run briefly then shut down; poor cooling performance.
Low-Pressure Protection / Low Refrigerant or Restricted Flow
E3
Trane air conditioner displays E3 and outdoor unit does not start or cycles off quickly.
Outdoor Fan Motor Fault / Fan Feedback Error
E4
Trane air conditioner shows E4 and shuts down; may be accompanied by ice on the indoor coil or very low airflow.
Evaporator Coil Freeze Protection / Low Airflow
E5
Trane air conditioner displays E5 and will not run or stops shortly after starting.
Overcurrent Protection / Compressor Overload
E6
Trane air conditioner shows E6 and may not respond to thermostat commands; indoor and outdoor units may not coordinate.
Indoor-Outdoor Communication Error / Data Link Failure
E7
Trane air conditioner displays E7 and the outdoor unit does not start; thermostat may show a communication or outdoor unit error.
Outdoor Unit Offline / No Feedback
E8
Trane air conditioner shows E8 and may shut down due to abnormal discharge temperature or compressor protection.
Discharge Temperature High / Compressor Overheat
E9
Trane air conditioner displays E9 and may not maintain set temperature; system may short-cycle.
Indoor Temperature Sensor Fault / Thermistor Error
F0
Trane air conditioner control shows F0 and system may not start or may run erratically.
EEPROM / Control Board Memory Error
F1
Trane air conditioner shows F1 and may not respond correctly to thermostat settings; temperature swings are noticeable.
Room Temperature Sensor Out of Range
F2
Trane air conditioner displays F2 and may shut down or limit operation; coil temperature readings appear abnormal.
Evaporator Coil Temperature Sensor Fault
F3
Trane air conditioner shows F3 and may stop cooling; outdoor unit may shut down on protection.
Outdoor Ambient Temperature Sensor Fault
F4
Trane air conditioner displays F4 and may limit compressor operation; defrost or protection modes may be affected on heat pump models.
Condenser Coil Temperature Sensor Fault
F5
Trane air conditioner shows F5 and may not start the compressor; system may run fan only.
Compressor Temperature Sensor Fault
F6
Trane air conditioner displays F6 and may not modulate capacity correctly on variable-speed or inverter models.
Compressor Current Sensor / Inverter Protection Fault
F7
Trane air conditioner shows F7 and may not start; fan may run but compressor stays off.
Phase Loss / Phase Reversal (Three-Phase Units)
F8
Trane air conditioner displays F8 and may shut down due to abnormal fan speed or feedback.
Indoor Fan Motor Feedback Fault (ECM/Variable-Speed)
F9
Trane air conditioner shows F9 and may not operate correctly in defrost or low ambient conditions (heat pump models).
Defrost Sensor / Defrost Control Fault
Symptom
Burning or electrical smell from the Trane indoor or outdoor unit during operation.
Overheating Electrical Component
Symptom
High-pitched squealing or screeching noise from the indoor Trane air handler or furnace when AC is running.
Blower Motor or Belt Noise
Symptom
Ice forming on the Trane outdoor unit refrigerant lines or on the indoor evaporator coil.
System Icing / Low Suction Pressure
Symptom
Musty or moldy odor from vents when the Trane air conditioner starts.
Biological Growth on Evaporator Coil or in Ducts
Symptom
Outdoor Trane air conditioner unit will not start at all; no fan, no compressor, thermostat appears normal.
No Power to Outdoor Condenser
Symptom
Trane air conditioner causes noticeable vibration and rattling noises in the outdoor unit or connected ductwork.
Excessive Vibration / Mounting Issues
Symptom
Trane air conditioner does not respond to thermostat changes; system stays off or stuck in one mode.
Control Logic / Thermostat Communication Issue
Symptom
Trane air conditioner indoor blower runs but airflow from vents is weak.
Insufficient Indoor Airflow
Symptom
Trane air conditioner indoor blower runs but outdoor unit does not; warm air blows from vents.
Outdoor Unit Not Responding to Cooling Call
Symptom
Trane air conditioner indoor unit is very noisy with a rattling or buzzing sound when the blower runs.
Loose Components in Air Handler
Symptom
Trane air conditioner outdoor fan runs but compressor does not; no cooling is produced.
Compressor Not Starting
Symptom
Trane air conditioner produces a loud banging or clanking noise from the outdoor unit during operation.
Mechanical Noise from Fan or Compressor
Symptom
Trane air conditioner runs but does not cool well; supply air is only slightly cooler than room temperature.
Poor Cooling Performance / Underperformance
Symptom
Trane air conditioner runs continuously and does not shut off even when the set temperature is reached.
Stuck Cooling Call / Control Staging Fault
Symptom
Trane air conditioner short cycles, turning on and off frequently without reaching set temperature.
Short Cycling / Improper System Control
Symptom
Trane air conditioner trips the breaker immediately or shortly after starting.
High Inrush or Short Circuit
Symptom
Trane air conditioner will not start; thermostat is blank or unresponsive.
No Thermostat Power / Control Circuit Failure
Symptom
Trane outdoor unit makes a loud humming sound but the fan and compressor do not start.
Failed Start/Run Capacitor
Symptom
Water dripping from the Trane outdoor unit base or excessive water around the pad.
Normal Condensation vs. Abnormal Outdoor Coil Frost Melt
Symptom
Water leaking from around the indoor Trane air handler or furnace during cooling operation.
Condensate Drain Clog / Drain Pan Overflow
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E0 |
Trane air conditioner control board display shows E0 and system will not start cooling or heating.
|
Communication Fault Between Indoor and Outdoor Unit | View Details |
| E1 |
Trane air conditioner displays E1 and shuts down or will not start; may attempt to start and then stop quickly.
|
High-Pressure Protection Trip | View Details |
| E2 |
Trane air conditioner shows E2 and may run briefly then shut down; poor cooling performance.
|
Low-Pressure Protection / Low Refrigerant or Restricted Flow | View Details |
| E3 |
Trane air conditioner displays E3 and outdoor unit does not start or cycles off quickly.
|
Outdoor Fan Motor Fault / Fan Feedback Error | View Details |
| E4 |
Trane air conditioner shows E4 and shuts down; may be accompanied by ice on the indoor coil or very low airflow.
|
Evaporator Coil Freeze Protection / Low Airflow | View Details |
| E5 |
Trane air conditioner displays E5 and will not run or stops shortly after starting.
|
Overcurrent Protection / Compressor Overload | View Details |
| E6 |
Trane air conditioner shows E6 and may not respond to thermostat commands; indoor and outdoor units may not coordinate.
|
Indoor-Outdoor Communication Error / Data Link Failure | View Details |
| E7 |
Trane air conditioner displays E7 and the outdoor unit does not start; thermostat may show a communication or outdoor unit error.
|
Outdoor Unit Offline / No Feedback | View Details |
| E8 |
Trane air conditioner shows E8 and may shut down due to abnormal discharge temperature or compressor protection.
|
Discharge Temperature High / Compressor Overheat | View Details |
| E9 |
Trane air conditioner displays E9 and may not maintain set temperature; system may short-cycle.
|
Indoor Temperature Sensor Fault / Thermistor Error | View Details |
| F0 |
Trane air conditioner control shows F0 and system may not start or may run erratically.
|
EEPROM / Control Board Memory Error | View Details |
| F1 |
Trane air conditioner shows F1 and may not respond correctly to thermostat settings; temperature swings are noticeable.
|
Room Temperature Sensor Out of Range | View Details |
| F2 |
Trane air conditioner displays F2 and may shut down or limit operation; coil temperature readings appear abnormal.
|
Evaporator Coil Temperature Sensor Fault | View Details |
| F3 |
Trane air conditioner shows F3 and may stop cooling; outdoor unit may shut down on protection.
|
Outdoor Ambient Temperature Sensor Fault | View Details |
| F4 |
Trane air conditioner displays F4 and may limit compressor operation; defrost or protection modes may be affected on heat pump models.
|
Condenser Coil Temperature Sensor Fault | View Details |
| F5 |
Trane air conditioner shows F5 and may not start the compressor; system may run fan only.
|
Compressor Temperature Sensor Fault | View Details |
| F6 |
Trane air conditioner displays F6 and may not modulate capacity correctly on variable-speed or inverter models.
|
Compressor Current Sensor / Inverter Protection Fault | View Details |
| F7 |
Trane air conditioner shows F7 and may not start; fan may run but compressor stays off.
|
Phase Loss / Phase Reversal (Three-Phase Units) | View Details |
| F8 |
Trane air conditioner displays F8 and may shut down due to abnormal fan speed or feedback.
|
Indoor Fan Motor Feedback Fault (ECM/Variable-Speed) | View Details |
| F9 |
Trane air conditioner shows F9 and may not operate correctly in defrost or low ambient conditions (heat pump models).
|
Defrost Sensor / Defrost Control Fault | View Details |
| – |
Burning or electrical smell from the Trane indoor or outdoor unit during operation.
|
Overheating Electrical Component | View Details |
| – |
High-pitched squealing or screeching noise from the indoor Trane air handler or furnace when AC is running.
|
Blower Motor or Belt Noise | View Details |
| – |
Ice forming on the Trane outdoor unit refrigerant lines or on the indoor evaporator coil.
|
System Icing / Low Suction Pressure | View Details |
| – |
Musty or moldy odor from vents when the Trane air conditioner starts.
|
Biological Growth on Evaporator Coil or in Ducts | View Details |
| – |
Outdoor Trane air conditioner unit will not start at all; no fan, no compressor, thermostat appears normal.
|
No Power to Outdoor Condenser | View Details |
| – |
Trane air conditioner causes noticeable vibration and rattling noises in the outdoor unit or connected ductwork.
|
Excessive Vibration / Mounting Issues | View Details |
| – |
Trane air conditioner does not respond to thermostat changes; system stays off or stuck in one mode.
|
Control Logic / Thermostat Communication Issue | View Details |
| – |
Trane air conditioner indoor blower runs but airflow from vents is weak.
|
Insufficient Indoor Airflow | View Details |
| – |
Trane air conditioner indoor blower runs but outdoor unit does not; warm air blows from vents.
|
Outdoor Unit Not Responding to Cooling Call | View Details |
| – |
Trane air conditioner indoor unit is very noisy with a rattling or buzzing sound when the blower runs.
|
Loose Components in Air Handler | View Details |
| – |
Trane air conditioner outdoor fan runs but compressor does not; no cooling is produced.
|
Compressor Not Starting | View Details |
| – |
Trane air conditioner produces a loud banging or clanking noise from the outdoor unit during operation.
|
Mechanical Noise from Fan or Compressor | View Details |
| – |
Trane air conditioner runs but does not cool well; supply air is only slightly cooler than room temperature.
|
Poor Cooling Performance / Underperformance | View Details |
| – |
Trane air conditioner runs continuously and does not shut off even when the set temperature is reached.
|
Stuck Cooling Call / Control Staging Fault | View Details |
| – |
Trane air conditioner short cycles, turning on and off frequently without reaching set temperature.
|
Short Cycling / Improper System Control | View Details |
| – |
Trane air conditioner trips the breaker immediately or shortly after starting.
|
High Inrush or Short Circuit | View Details |
| – |
Trane air conditioner will not start; thermostat is blank or unresponsive.
|
No Thermostat Power / Control Circuit Failure | View Details |
| – |
Trane outdoor unit makes a loud humming sound but the fan and compressor do not start.
|
Failed Start/Run Capacitor | View Details |
| – |
Water dripping from the Trane outdoor unit base or excessive water around the pad.
|
Normal Condensation vs. Abnormal Outdoor Coil Frost Melt | View Details |
| – |
Water leaking from around the indoor Trane air handler or furnace during cooling operation.
|
Condensate Drain Clog / Drain Pan Overflow | View Details |