Fondital Boilers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
A01
Boiler does not ignite, display shows A01, no flame symbol, heating and hot water unavailable
Ignition Failure / No Flame Detection
A02
Boiler locks out with A02, burner shuts down shortly after ignition, repeated failed starts
Flame Loss During Operation
A03
Boiler stops with A03, temperature rises quickly, radiators very hot, pump may be noisy
Overheating / Safety Thermostat Intervention
A04
Boiler shows A04, will not start, pressure gauge indicates low or zero pressure
Low Water Pressure / Insufficient System Charge
A05
Boiler displays A05, fan runs but burner does not ignite, sometimes accompanied by whistling or wind noise
Flue Gas Exhaust / Air Pressure Fault
A06
Boiler shows A06, ignition attempts are irregular, sometimes with loud clicking, no stable flame
Ignition Control / Spark Fault
A07
Boiler locks out with A07, fan may run continuously, no ignition sequence
Fan / Airflow Control Fault
A08
Boiler shows A08, no heating or hot water, pump may run briefly then stop
Flow Sensor / Circulation Fault
A09
Boiler displays A09, domestic hot water temperature unstable or excessively hot
DHW Temperature Sensor / Modulation Fault
A10
Boiler shows A10, heating temperature reading is incorrect or fluctuates rapidly
Flow/Return NTC Sensor Fault
A11
Boiler displays A11, burner stops, sometimes accompanied by gurgling noises in the boiler
Insufficient Water Circulation / Air in System
A12
Boiler shows A12, no domestic hot water even though heating works correctly
DHW Flow Detection Fault
A13
Boiler locks out with A13, often after long operation, casing may feel unusually warm
Flue Gas Overtemperature / Safety Cut-out
A14
Boiler shows A14, burner stops, may occur during DHW draw-off, water temperature drops suddenly
Gas Valve Modulation / Overpressure Fault
A15
Boiler displays A15, no response to thermostat demand, heating symbol may flash
Room Thermostat / External Control Fault
A16
Boiler shows A16, heating temperature limited, boiler may cycle frequently
Return Temperature Sensor / Anti-condensation Control Fault
A17
Boiler displays A17, pump runs but burner does not start, especially in heating mode
Flow Switch / Differential Pressure Fault
A18
Boiler shows A18, condensate may be visible around the base, unit may be noisy
Condensate Drain / Siphon Fault
A19
Boiler displays A19, burner stops, may coincide with gas meter change or supply interruption
Gas Supply Interruption / Lockout
A20
Boiler shows A20, display may indicate communication error with remote control or zone module
Communication Fault (Bus Error)
Symptom
Boiler display is blank or intermittently turns off, but mains power is present
Power Supply / Control Panel Fault
Symptom
Boiler does not produce hot water when more than one tap is opened
Insufficient DHW Capacity / Flow Limitation
Symptom
Boiler does not respond to heating demand, but hot water works normally
Heating Demand / Diverter Valve Fault
Symptom
Boiler emits a burning smell or plastic odour during operation
Overheating Electrical Component or Dust Burn-off
Symptom
Boiler fan runs continuously even when there is no heating or hot water demand
Fan Overrun / Stuck Relay
Symptom
Boiler flue terminal shows white staining and there is excessive condensate dripping outside
Condensate Management / Flue Installation Issue
Symptom
Boiler frequently goes into anti-cycling or anti-freeze mode even when not required
Control Logic / Sensor Placement Issue
Symptom
Boiler frequently loses pressure and needs topping up every few days
Chronic Pressure Loss
Symptom
Boiler ignites with a loud bang or pop (delayed ignition)
Delayed Ignition / Gas-Air Mixture Fault
Symptom
Boiler leaking water from underneath the casing or from safety valve discharge pipe
Internal Water Leak / Overpressure Discharge
Symptom
Boiler makes loud banging or knocking noises when starting or stopping heating
Kettling / Thermal Shock in Heat Exchanger
Symptom
Boiler runs but gas consumption seems unusually high compared to previous seasons
Reduced Efficiency / Combustion or Scaling Issue
Symptom
Boiler runs for only a short time then stops, radiators never reach set temperature
Short Cycling / Oversized Boiler or Sensor Misreading
Symptom
Boiler vibrates excessively or resonates through the flue and pipework during operation
Mechanical Vibration / Fan or Pump Imbalance
Symptom
Domestic hot water temperature fluctuates between hot and cold during shower use
Inconsistent DHW Temperature Control
Symptom
Radiators only partially heat up or some remain cold while boiler runs
Poor Circulation / System Balancing Issue