Zodiac

Zodiac Pool Heaters Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Zodiac gas pool heater will not ignite; display shows E01 shortly after a call for heat.
Ignition Failure / Ignition Lockout
E02
Zodiac pool heater starts ignition sequence but shuts down with E02; blower may run briefly then stop.
Flame Loss / Flame Proving Failure
E03
Zodiac pool heater displays E03 and will not fire; may occur immediately on a call for heat.
Pressure Switch / Water Flow Fault
E04
Zodiac pool heater shows E04 and shuts down; often occurs shortly after startup.
High Limit Switch Trip / Overheat Condition
E05
Zodiac pool heater displays E05; heater will not start or shuts down quickly.
Exhaust Temperature / Flue Sensor Fault
E06
Zodiac pool heater shows E06; heater does not respond properly to temperature settings.
Water Temperature Sensor (Thermistor) Fault
E07
Zodiac pool heater displays E07 and will not fire; may occur intermittently.
Air Flow / Blower Proving Fault
E08
Zodiac pool heater shows E08; control panel may be unresponsive or display erratic readings.
Control Board Communication / Internal Fault
E09
Zodiac pool heater displays E09; heater may start but shuts down or may not start at all.
Gas Valve / Gas Control Fault
E10
Zodiac pool heater shows E10; unit may not recognize external controls or may ignore local keypad commands.
External Control / Interface Fault
E11
Zodiac pool heater displays E11; ignition may start but then lock out.
Flame Sense Circuit Error
E12
Zodiac pool heater shows E12; may be accompanied by erratic temperature readings or unexpected shutdowns.
Outlet Water Temperature Sensor Fault
E13
Zodiac pool heater displays E13; heater may shut down during operation, especially in windy conditions.
Rollout Switch / Flame Rollout Fault
E14
Zodiac pool heater shows E14; unit may not respond to keypad inputs or may lock up.
Keypad / User Interface Fault
E15
Zodiac pool heater displays E15; heater may not start and may indicate a safety chain issue.
Safety Circuit Open (Limit String Open)
E16
Zodiac pool heater shows E16; may be associated with low-voltage or power issues.
Low Line Voltage / Power Supply Fault
E17
Zodiac pool heater displays E17; may occur when switching between pool and spa modes.
Mode / Sensor Mismatch Fault
E18
Zodiac pool heater shows E18; heater may shut down during operation with no obvious mechanical issue.
Internal Overcurrent / Board Protection Fault
E19
Zodiac pool heater displays E19; may coincide with erratic or no blower operation.
Blower Speed / Feedback Fault
E20
Zodiac pool heater shows E20; heater may not recognize water flow correctly even when pump is running.
Flow Sensor / Switch Fault (Heaters with Electronic Flow Sensing)
Symptom
Zodiac pool heater blower is very loud, squeals, or vibrates excessively during operation.
Blower Mechanical Wear / Imbalance
Symptom
Zodiac pool heater cabinet shows rust and corrosion, especially near the base and around water connections.
Cabinet Corrosion / Environmental Damage
Symptom
Zodiac pool heater causes the circuit breaker to trip when it starts.
Electrical Overload / Short Circuit
Symptom
Zodiac pool heater cycles on and off frequently without maintaining a stable temperature.
Short Cycling / Control Instability
Symptom
Zodiac pool heater display is on but does not respond to button presses.
Keypad Failure / Stuck Buttons
Symptom
Zodiac pool heater display shows very inaccurate water temperature compared to an external thermometer.
Temperature Sensing Error / Calibration Drift
Symptom
Zodiac pool heater emits a strong gas smell around the unit, especially at startup.
Gas Leak / Incomplete Combustion
Symptom
Zodiac pool heater ignites but then shuts off after a few seconds without an error code.
Flame Sensing Intermittent / Marginal Flame Signal
Symptom
Zodiac pool heater is installed on a saltwater pool and shows accelerated corrosion and internal scaling.
Saltwater Corrosion / Scale Accumulation
Symptom
Zodiac pool heater leaks water from the bottom of the cabinet.
Internal Water Leak / Heat Exchanger or Manifold Leak
Symptom
Zodiac pool heater makes loud banging or popping noises during operation.
Delayed Ignition / Combustion Instability
Symptom
Zodiac pool heater repeatedly locks out and must be manually reset to restart.
Repeated Ignition Lockout / Safety Lockout
Symptom
Zodiac pool heater runs but causes excessive condensation or steam at the exhaust.
Condensation / Low Return Water Temperature
Symptom
Zodiac pool heater runs but water does not reach set temperature or heats very slowly.
Insufficient Heating Capacity / Underfiring
Symptom
Zodiac pool heater shuts down when it rains or in very humid conditions.
Moisture Intrusion / Condensation Fault
Symptom
Zodiac pool heater shuts off when the pump speed is reduced on a variable-speed pump.
Flow-Dependent Shutdown / Pressure Switch Sensitivity
Symptom
Zodiac pool heater will not start at all; display is blank or does not light.
No Power / Dead Control
Advertisements