E0
Gas cooktop with electronic ignition shows E0 on display and burners will not ignite
Ignition System Supply Fault
E1
Gas cooktop display shows E1 and gas valves do not open on electronic models
Gas Safety Valve or Solenoid Fault
E2
Gas cooktop with flame supervision shows E2 and burners shut off shortly after ignition
Flame Failure Device / Thermocouple Fault
E3
Gas cooktop shows E3 and ignition sparks continuously even when burners are lit
Ignition Sensing / Spark Module Fault
E4
Gas cooktop display shows E4 and one burner will not ignite, others work normally
Individual Burner Ignition Failure
E5
Gas cooktop shows E5 and shuts off gas supply shortly after ignition on all burners
Global Flame Supervision / Safety Lockout
E6
Gas cooktop with digital timer shows E6 and timer functions are disabled
Timer / Auxiliary Control Board Fault
F0
Induction cooktop beeps and will not start heating, display shows F0 on one or more zones
Pan Detection Failure
F1
Cooktop zone shuts down shortly after being turned on, display shows F1
Glass Surface Temperature Sensor Fault
F2
Induction zone stops heating and F2 appears on the display
Zone Overtemperature Protection Activated
F3
Cooktop displays F3 and will not allow power level selection on one or more zones
Touch Control Panel Sensor Error
F4
Cooktop shows F4 and all zones are disabled
Main Power Board Communication Failure
F5
Single induction zone shows F5 and does not heat
Induction Power Module Failure (Zone-Specific)
F6
Cooktop displays F6 and may shut down unexpectedly during use
Supply Voltage Out of Range
F7
Cooktop shows F7 and does not respond to touch inputs
Key Lock / Child Lock or Control Panel Lock Error
F8
Induction cooktop displays F8 and zones may pulse or not heat correctly
Cooling System Failure
F9
Cooktop shows F9 and shuts down when multiple zones are used at high power
Internal Overcurrent / Power Management Fault
L
Cooktop shows 'L' and will not respond to power level changes
Child Lock Activated
U
Induction cooktop shows a 'U' or similar symbol and zone does not heat
No Cookware Detected / Unsuitable Pan
Symptom
Condensation or water appears under glass or in control area after cooking
Moisture Ingress / Ventilation Issue
Symptom
Continuous clicking (sparking) from gas cooktop even when all knobs are in OFF position
Stuck Ignition Switch or Moisture in Ignition System
Symptom
Cooktop emits a burning smell or visible smoke during operation
Overheating or Electrical Insulation Failure
Symptom
Cooktop frame or metal parts give a mild electric shock when touched
Improper Grounding or Insulation Fault
Symptom
Cooktop glass surface is cracked or shattered
Ceramic Glass Top Damage
Symptom
Cooktop makes loud buzzing or humming noises during operation
Induction Coil Vibration or Loose Components
Symptom
Cooktop surface around burners or zones becomes excessively hot
Heat Transfer / Insulation Issue
Symptom
Cooktop trips the circuit breaker or RCD when turned on
Short Circuit or Earth Leakage
Symptom
Gas burner clicks (sparks) but flame does not appear or is very weak
Gas Flow Restriction at Burner
Symptom
Gas burner flame goes out when knob is released
Thermocouple Not Holding Gas Valve Open
Symptom
Gas burner flame is yellow, sooty, or lifts off the burner
Incorrect Combustion / Air-Gas Mixture
Symptom
Gas burner will not ignite (no clicking, no spark) on one or more burners
Ignition System Failure
Symptom
Gas smell near cooktop when burners are off
Gas Leak at Connection or Valve
Symptom
Indicator lights or residual heat indicators do not work, but zones heat normally
Indicator Circuit Failure
Symptom
Induction cooktop does not power on at all (no lights, no display)
No Power / Main Supply Failure
Symptom
Induction cooktop powers on but none of the zones heat (no error code)
Zone Enable / Relay or Power Stage Failure
Symptom
Induction cooktop touch controls are unresponsive or erratic
Touch Sensor Malfunction
Symptom
Induction cooktop zone intermittently shuts off or reduces power when multiple zones are used
Power Sharing / Load Management Limitation
Symptom
Timer or automatic shutoff functions do not work correctly
Timer Control Malfunction
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E0 |
Gas cooktop with electronic ignition shows E0 on display and burners will not ignite
|
Ignition System Supply Fault | View Details |
| E1 |
Gas cooktop display shows E1 and gas valves do not open on electronic models
|
Gas Safety Valve or Solenoid Fault | View Details |
| E2 |
Gas cooktop with flame supervision shows E2 and burners shut off shortly after ignition
|
Flame Failure Device / Thermocouple Fault | View Details |
| E3 |
Gas cooktop shows E3 and ignition sparks continuously even when burners are lit
|
Ignition Sensing / Spark Module Fault | View Details |
| E4 |
Gas cooktop display shows E4 and one burner will not ignite, others work normally
|
Individual Burner Ignition Failure | View Details |
| E5 |
Gas cooktop shows E5 and shuts off gas supply shortly after ignition on all burners
|
Global Flame Supervision / Safety Lockout | View Details |
| E6 |
Gas cooktop with digital timer shows E6 and timer functions are disabled
|
Timer / Auxiliary Control Board Fault | View Details |
| F0 |
Induction cooktop beeps and will not start heating, display shows F0 on one or more zones
|
Pan Detection Failure | View Details |
| F1 |
Cooktop zone shuts down shortly after being turned on, display shows F1
|
Glass Surface Temperature Sensor Fault | View Details |
| F2 |
Induction zone stops heating and F2 appears on the display
|
Zone Overtemperature Protection Activated | View Details |
| F3 |
Cooktop displays F3 and will not allow power level selection on one or more zones
|
Touch Control Panel Sensor Error | View Details |
| F4 |
Cooktop shows F4 and all zones are disabled
|
Main Power Board Communication Failure | View Details |
| F5 |
Single induction zone shows F5 and does not heat
|
Induction Power Module Failure (Zone-Specific) | View Details |
| F6 |
Cooktop displays F6 and may shut down unexpectedly during use
|
Supply Voltage Out of Range | View Details |
| F7 |
Cooktop shows F7 and does not respond to touch inputs
|
Key Lock / Child Lock or Control Panel Lock Error | View Details |
| F8 |
Induction cooktop displays F8 and zones may pulse or not heat correctly
|
Cooling System Failure | View Details |
| F9 |
Cooktop shows F9 and shuts down when multiple zones are used at high power
|
Internal Overcurrent / Power Management Fault | View Details |
| L |
Cooktop shows 'L' and will not respond to power level changes
|
Child Lock Activated | View Details |
| U |
Induction cooktop shows a 'U' or similar symbol and zone does not heat
|
No Cookware Detected / Unsuitable Pan | View Details |
| – |
Condensation or water appears under glass or in control area after cooking
|
Moisture Ingress / Ventilation Issue | View Details |
| – |
Continuous clicking (sparking) from gas cooktop even when all knobs are in OFF position
|
Stuck Ignition Switch or Moisture in Ignition System | View Details |
| – |
Cooktop emits a burning smell or visible smoke during operation
|
Overheating or Electrical Insulation Failure | View Details |
| – |
Cooktop frame or metal parts give a mild electric shock when touched
|
Improper Grounding or Insulation Fault | View Details |
| – |
Cooktop glass surface is cracked or shattered
|
Ceramic Glass Top Damage | View Details |
| – |
Cooktop makes loud buzzing or humming noises during operation
|
Induction Coil Vibration or Loose Components | View Details |
| – |
Cooktop surface around burners or zones becomes excessively hot
|
Heat Transfer / Insulation Issue | View Details |
| – |
Cooktop trips the circuit breaker or RCD when turned on
|
Short Circuit or Earth Leakage | View Details |
| – |
Gas burner clicks (sparks) but flame does not appear or is very weak
|
Gas Flow Restriction at Burner | View Details |
| – |
Gas burner flame goes out when knob is released
|
Thermocouple Not Holding Gas Valve Open | View Details |
| – |
Gas burner flame is yellow, sooty, or lifts off the burner
|
Incorrect Combustion / Air-Gas Mixture | View Details |
| – |
Gas burner will not ignite (no clicking, no spark) on one or more burners
|
Ignition System Failure | View Details |
| – |
Gas smell near cooktop when burners are off
|
Gas Leak at Connection or Valve | View Details |
| – |
Indicator lights or residual heat indicators do not work, but zones heat normally
|
Indicator Circuit Failure | View Details |
| – |
Induction cooktop does not power on at all (no lights, no display)
|
No Power / Main Supply Failure | View Details |
| – |
Induction cooktop powers on but none of the zones heat (no error code)
|
Zone Enable / Relay or Power Stage Failure | View Details |
| – |
Induction cooktop touch controls are unresponsive or erratic
|
Touch Sensor Malfunction | View Details |
| – |
Induction cooktop zone intermittently shuts off or reduces power when multiple zones are used
|
Power Sharing / Load Management Limitation | View Details |
| – |
Timer or automatic shutoff functions do not work correctly
|
Timer Control Malfunction | View Details |