E01
Thermostat display shows E01 and cannot connect to the Wiser Heat Hub or app
Wi‑Fi / Zigbee Radio Communication Failure
E02
Thermostat shows E02 and does not control heating correctly
Internal Temperature Sensor Failure
E03
Thermostat displays E03 and heating does not respond to setpoint changes
Relay / Output Driver Fault
E04
Thermostat shows E04 and cannot detect the boiler or heating circuit
Boiler Demand Signal / Call-for-Heat Circuit Fault
E05
Thermostat shows E05 and hot water control is unavailable
Hot Water Channel Output Fault
E06
Thermostat shows E06 and room temperature reading is clearly wrong (e.g. -20°C or 60°C)
Room Temperature Sensor Out of Range
E07
Thermostat shows E07 and cannot control underfloor heating temperature correctly
Remote Floor Sensor Fault (for UFH setups)
E08
Thermostat shows E08 and battery icon flashes or device powers off intermittently
Low Battery / Power Supply Fault
E09
Thermostat shows E09 and cannot join the Wiser system after a reset
Pairing / Commissioning Failure
E10
Thermostat shows E10 and schedules do not run; time and date keep resetting
Real-Time Clock / Memory Fault
E11
Thermostat shows E11 and cannot control a specific smart radiator thermostat (TRV)
Zigbee Device Link Failure (Smart Radiator Thermostat)
E12
Thermostat shows E12 and cannot control a specific heating zone or room
Zone Binding / Mapping Error
E13
Thermostat shows E13 and the app reports a firmware update failure
Firmware Update / Flash Write Error
E14
Thermostat shows E14 and the display is frozen or unresponsive to touch/buttons
User Interface / Touch Panel Fault
E15
Thermostat shows E15 and the boiler cycles rapidly or does not respond correctly
OpenTherm / Digital Boiler Communication Fault (where supported)
E16
Thermostat shows E16 and reports over-temperature or safety shutdown
Over-Temperature Protection Triggered
E17
Thermostat shows E17 and cannot connect to the internet or Wiser cloud services
Cloud / Internet Connectivity Fault
E18
Thermostat shows E18 and reports humidity sensor error (on models with humidity)
Internal Humidity Sensor Failure
E19
Thermostat shows E19 and cannot control cooling (for heat pump / cooling-enabled systems)
Cooling Output / Reversing Valve Control Fault
E20
Thermostat shows E20 and reports sensor calibration error
Sensor Calibration / Offset Error
Symptom
Condensation or visible moisture inside thermostat cover
Moisture Ingress / Environmental Damage Risk
Symptom
Heating stays on constantly even when the thermostat is set low or off
Stuck Relay / Permanent Call-for-Heat
Symptom
Heating will not turn on even though the thermostat is calling for heat (no error code shown)
No Heat Output / Call-for-Heat Not Reaching Boiler
Symptom
Hot water does not heat up according to schedule, but heating works normally
Hot Water Control / Scheduling Fault
Symptom
Room never reaches the set temperature; heating cuts off early
Under-Heating / Early Cut-Off
Symptom
Room temperature overshoots setpoint by several degrees before heating turns off
Poor Temperature Control / Overshoot
Symptom
Smart radiator thermostats (TRVs) do not open or close properly; some rooms stay cold or hot
Smart Radiator Thermostat Mechanical / Control Fault
Symptom
Thermostat backlight flickers or display intermittently dims
Display Power / Backlight Instability
Symptom
Thermostat buttons are stiff or do not click properly (on button-based models)
Mechanical Button Wear / Contamination
Symptom
Thermostat display is completely blank and unresponsive
No Power to Thermostat
Symptom
Thermostat does not respond to voice assistant commands (e.g. Alexa, Google) but works locally
Third-Party Integration / API Fault
Symptom
Thermostat emits a burning smell or feels unusually hot to the touch
Overheating Electronics / Potential Short
Symptom
Thermostat frequently disconnects from the app or shows as offline
Intermittent Wireless Connectivity
Symptom
Thermostat makes clicking noises but boiler does not start
Relay Operating but No Boiler Response
Symptom
Thermostat randomly resets or restarts during normal operation
Unexpected Reboot / Power Instability
Symptom
Thermostat shows large, sudden jumps in temperature reading (e.g. 20°C to 28°C within minutes) without environmental change
Erratic Temperature Sensing
Symptom
Thermostat time schedule does not follow programmed times; heating turns on/off at wrong times
Scheduling / Timekeeping Issue
Advertisements