Vokera
Vokera Boilers Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
01
Boiler will not ignite, display shows fault code 01, no heating or hot water
Ignition Failure / Flame Not Detected
02
Boiler locks out with code 02, fan runs but no ignition, or ignition stops quickly
Flame Detection Failure / Flame Signal Lost
03
Boiler shows 03 and shuts down, fan may not start, no ignition sequence
Fan / Air Pressure Switch Fault
04
Boiler displays 04 and locks out, no heating or hot water
Ignition Lockout / Repeated Failed Starts
05
Boiler shows 05, will not fire, may attempt ignition then shut down
Overheat Thermostat Tripped
06
Boiler displays 06, temperature rises rapidly then locks out
Flow Temperature Sensor Fault / Overheat Detection
07
Boiler shows 07, may run briefly then shut down, temperature readings erratic
Return Temperature Sensor Fault
08
Boiler displays 08, no heating or hot water, may indicate flue/air fault
Air Pressure Switch / Flue System Fault
09
Boiler shows 09, fan runs continuously or not at all, no ignition
Fan Speed / Fan Feedback Fault
10
Boiler displays 10, no heating or hot water, may indicate flue/ventilation issue
Flue Gas Safety / Combustion Fault
11
Boiler shows 11, will not start, may indicate low water pressure or circulation fault
Low System Pressure / Water Circulation Fault
12
Boiler displays 12, heating demand not recognised or boiler cycles rapidly
Flow Switch / Flow Sensor Fault (DHW or CH depending on model)
13
Boiler shows 13, temperature readings unstable, boiler may short-cycle
Domestic Hot Water NTC Sensor Fault
20
Boiler displays 20, no response to thermostat, heating will not start
External Control / Room Thermostat Circuit Fault
23
Boiler shows 23, may indicate pump or circulation fault, overheating on flow
Pump Fault / Insufficient Circulation
24
Boiler displays 24, pressure gauge may be high, water discharged from PRV
High System Pressure / Expansion Vessel Fault
25
Boiler shows 25, no heating, may indicate sensor or PCB fault
General Temperature Sensor / PCB Fault
27
Boiler displays 27, intermittent lockouts, may relate to ionisation/flame signal
Flame Signal Instability
40
Boiler shows 40, no heating or hot water, may indicate lockout due to repeated faults
General Lockout / Multiple Fault Condition
A01
Vokera boiler (e.g. Compact, Easi-Heat, Vision) shows A01, no flame detected
Ignition Failure (Modern Alpha Code)
A02
Boiler shows A02, overheat condition, boiler very hot then shuts down
Primary Circuit Overheat
A03
Boiler displays A03, fan/flue related fault, no ignition
Flue Fan / Air Pressure Fault (Alpha Code)
A04
Boiler shows A04, low water pressure, no heating
Low System Pressure (Alpha Code)
A06
Boiler displays A06, NTC sensor fault indicated, boiler may not fire
Flow or Return NTC Sensor Error (Alpha Code)
A07
Boiler shows A07, DHW temperature sensor fault, unstable hot water temperature
DHW NTC Sensor Error (Alpha Code)
A08
Boiler displays A08, pump or circulation related fault, may overheat quickly
Pump / Circulation Fault (Alpha Code)
A09
Boiler shows A09, flue gas over-temperature or flue sensor fault (on models fitted)
Flue Gas Temperature Fault
Symptom
Boiler display is on but does not respond to controls or buttons
User Interface / Control Panel Fault
Symptom
Boiler frequently loses pressure and needs topping up every few days
Chronic Pressure Loss
Symptom
Boiler leaking water from underneath the casing or pipe connections
Internal Water Leak
Symptom
Boiler locks out more often during very cold weather, external pipework affected
Frozen Condensate Pipe
Symptom
Boiler makes loud banging or kettling noises during operation, especially on heating
Kettling / Localised Boiling in Heat Exchanger
Symptom
Boiler makes loud humming, vibrating, or rattling noises during operation
Mechanical Vibration / Resonance
Symptom
Boiler or flue emits unusual smells (burning, metallic, or exhaust-like odour)
Combustion / Overheating Smell
Symptom
Boiler provides hot water but central heating does not come on, even though thermostat is calling
No Central Heating Demand / Diverter Valve Stuck
Symptom
Boiler randomly turns off and on, or cuts out before reaching set temperature
Short Cycling / Intermittent Operation
Symptom
Boiler runs for central heating but does not provide any hot water at the taps
No Domestic Hot Water on Combi Boiler
Symptom
Boiler will not start at all, no lights or display
No Power / Dead Boiler
Symptom
Condensate water dripping from the bottom of the boiler casing or flue joints
Condensate Drain / Trap Issue
Symptom
Hot water temperature fluctuates between hot and cold when using a tap or shower
Inconsistent Domestic Hot Water Temperature
Symptom
Radiators only get warm at the bottom or some radiators stay cold while boiler runs
Poor Heating Circulation / Sludge Build-up
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| 01 |
Boiler will not ignite, display shows fault code 01, no heating or hot water
|
Ignition Failure / Flame Not Detected | View Details |
| 02 |
Boiler locks out with code 02, fan runs but no ignition, or ignition stops quickly
|
Flame Detection Failure / Flame Signal Lost | View Details |
| 03 |
Boiler shows 03 and shuts down, fan may not start, no ignition sequence
|
Fan / Air Pressure Switch Fault | View Details |
| 04 |
Boiler displays 04 and locks out, no heating or hot water
|
Ignition Lockout / Repeated Failed Starts | View Details |
| 05 |
Boiler shows 05, will not fire, may attempt ignition then shut down
|
Overheat Thermostat Tripped | View Details |
| 06 |
Boiler displays 06, temperature rises rapidly then locks out
|
Flow Temperature Sensor Fault / Overheat Detection | View Details |
| 07 |
Boiler shows 07, may run briefly then shut down, temperature readings erratic
|
Return Temperature Sensor Fault | View Details |
| 08 |
Boiler displays 08, no heating or hot water, may indicate flue/air fault
|
Air Pressure Switch / Flue System Fault | View Details |
| 09 |
Boiler shows 09, fan runs continuously or not at all, no ignition
|
Fan Speed / Fan Feedback Fault | View Details |
| 10 |
Boiler displays 10, no heating or hot water, may indicate flue/ventilation issue
|
Flue Gas Safety / Combustion Fault | View Details |
| 11 |
Boiler shows 11, will not start, may indicate low water pressure or circulation fault
|
Low System Pressure / Water Circulation Fault | View Details |
| 12 |
Boiler displays 12, heating demand not recognised or boiler cycles rapidly
|
Flow Switch / Flow Sensor Fault (DHW or CH depending on model) | View Details |
| 13 |
Boiler shows 13, temperature readings unstable, boiler may short-cycle
|
Domestic Hot Water NTC Sensor Fault | View Details |
| 20 |
Boiler displays 20, no response to thermostat, heating will not start
|
External Control / Room Thermostat Circuit Fault | View Details |
| 23 |
Boiler shows 23, may indicate pump or circulation fault, overheating on flow
|
Pump Fault / Insufficient Circulation | View Details |
| 24 |
Boiler displays 24, pressure gauge may be high, water discharged from PRV
|
High System Pressure / Expansion Vessel Fault | View Details |
| 25 |
Boiler shows 25, no heating, may indicate sensor or PCB fault
|
General Temperature Sensor / PCB Fault | View Details |
| 27 |
Boiler displays 27, intermittent lockouts, may relate to ionisation/flame signal
|
Flame Signal Instability | View Details |
| 40 |
Boiler shows 40, no heating or hot water, may indicate lockout due to repeated faults
|
General Lockout / Multiple Fault Condition | View Details |
| A01 |
Vokera boiler (e.g. Compact, Easi-Heat, Vision) shows A01, no flame detected
|
Ignition Failure (Modern Alpha Code) | View Details |
| A02 |
Boiler shows A02, overheat condition, boiler very hot then shuts down
|
Primary Circuit Overheat | View Details |
| A03 |
Boiler displays A03, fan/flue related fault, no ignition
|
Flue Fan / Air Pressure Fault (Alpha Code) | View Details |
| A04 |
Boiler shows A04, low water pressure, no heating
|
Low System Pressure (Alpha Code) | View Details |
| A06 |
Boiler displays A06, NTC sensor fault indicated, boiler may not fire
|
Flow or Return NTC Sensor Error (Alpha Code) | View Details |
| A07 |
Boiler shows A07, DHW temperature sensor fault, unstable hot water temperature
|
DHW NTC Sensor Error (Alpha Code) | View Details |
| A08 |
Boiler displays A08, pump or circulation related fault, may overheat quickly
|
Pump / Circulation Fault (Alpha Code) | View Details |
| A09 |
Boiler shows A09, flue gas over-temperature or flue sensor fault (on models fitted)
|
Flue Gas Temperature Fault | View Details |
| – |
Boiler display is on but does not respond to controls or buttons
|
User Interface / Control Panel Fault | View Details |
| – |
Boiler frequently loses pressure and needs topping up every few days
|
Chronic Pressure Loss | View Details |
| – |
Boiler leaking water from underneath the casing or pipe connections
|
Internal Water Leak | View Details |
| – |
Boiler locks out more often during very cold weather, external pipework affected
|
Frozen Condensate Pipe | View Details |
| – |
Boiler makes loud banging or kettling noises during operation, especially on heating
|
Kettling / Localised Boiling in Heat Exchanger | View Details |
| – |
Boiler makes loud humming, vibrating, or rattling noises during operation
|
Mechanical Vibration / Resonance | View Details |
| – |
Boiler or flue emits unusual smells (burning, metallic, or exhaust-like odour)
|
Combustion / Overheating Smell | View Details |
| – |
Boiler provides hot water but central heating does not come on, even though thermostat is calling
|
No Central Heating Demand / Diverter Valve Stuck | View Details |
| – |
Boiler randomly turns off and on, or cuts out before reaching set temperature
|
Short Cycling / Intermittent Operation | View Details |
| – |
Boiler runs for central heating but does not provide any hot water at the taps
|
No Domestic Hot Water on Combi Boiler | View Details |
| – |
Boiler will not start at all, no lights or display
|
No Power / Dead Boiler | View Details |
| – |
Condensate water dripping from the bottom of the boiler casing or flue joints
|
Condensate Drain / Trap Issue | View Details |
| – |
Hot water temperature fluctuates between hot and cold when using a tap or shower
|
Inconsistent Domestic Hot Water Temperature | View Details |
| – |
Radiators only get warm at the bottom or some radiators stay cold while boiler runs
|
Poor Heating Circulation / Sludge Build-up | View Details |
No matching codes found