E10
Dryer will not start a cycle or stops shortly after start; sometimes displays E10 shortly after pressing start.
Water Inlet / Condenser Rinsing System Fault
E20
Dryer stops mid-cycle, clothes still damp, may display E20 and sometimes water remains in the base tray (for condenser/heat pump models).
Drain / Condensate Pump Fault
E21
Dryer stops with E21, often shortly after start; may not pump out condensate water and may trigger leak tray float switch on some models.
Condensate Pump Blocked or Jammed
E30
Dryer will not start or stops and displays E30; sometimes accompanied by a beeping alarm and water in the base tray.
Leakage / Anti-Flood System Activated
E40
Dryer does not start; display shows E40 or a door symbol; door may appear closed but cycle will not begin.
Door Lock / Door Switch Fault
E41
Dryer displays E41 and will not start; door appears closed but machine thinks it is open.
Door Not Properly Closed Signal
E42
Dryer shows E42; door may remain locked or unlocked incorrectly; cycle may not start or may stop unexpectedly.
Door Locking Circuit Fault
E50
Dryer drum does not turn or stops during cycle; E50 or related motor error appears on display.
Motor / Motor Control Fault
E51
Dryer will not start drum rotation; E51 displayed; sometimes trips household breaker when attempting to start.
Motor Triac Short-Circuit on Control Board
E52
Dryer may start but stops shortly after; E52 displayed; drum movement may be erratic.
Motor Tachometer Signal Fault
E53
Dryer may not start or may stop with E53; sometimes associated with erratic motor speed.
Motor Control Circuit Fault
E54
Dryer may trip the breaker or show E54 when starting or reversing drum direction.
Motor Relay Stuck or Faulty
E60
Dryer does not heat or stops with E60; clothes remain cold and wet even after full cycle.
Heating System General Fault
E61
Dryer heats up very slowly; drying times are excessively long; E61 may be stored as a service code.
Insufficient Heating Performance
E62
Dryer overheats quickly; drum and door become very hot; cycle may stop with E62.
Overheating / Over-Temperature Fault
E63
Dryer stops heating mid-cycle; E63 displayed; may restart after cooling down.
Heater Safety Cut-Out / Overheat Protection Activated
E64
Dryer runs but never heats; E64 stored or displayed; clothes remain cold.
Heater Relay or Heater Circuit Open
E70
Dryer may not heat correctly; E70 or related sensor error stored; temperature readings appear incorrect.
NTC Temperature Sensor Circuit Fault
E71
Dryer may not start heating; E71 displayed or logged; control detects NTC out of range (open circuit).
NTC Sensor Open-Circuit
E72
Dryer may overheat or underheat; E72 logged; second NTC sensor (if fitted) out of range.
Secondary NTC Sensor Fault
E80
Dryer display or selector behaves erratically; E80 or similar appears; wrong program may be detected.
Program Selector / User Interface Fault
E90
Dryer will not start; E90 or related communication error appears; display may be blank or frozen.
Communication Error Between Main Board and User Interface
E91
Dryer display may light but controls are unresponsive; E91 logged as communication error.
No Communication from User Interface
E92
Dryer may start with wrong configuration; E92 logged; unusual behavior after board replacement.
Configuration / EEPROM Error
E93
Dryer shows configuration error after service; some programs missing or not working.
Incorrect Configuration Data
E94
Dryer may not start or may run incorrect cycles; E94 stored; configuration mismatch.
Program Configuration Error
Symptom
Dryer control panel buttons are unresponsive or only some buttons work intermittently.
User Interface Keypad Fault
Symptom
Dryer display shows that the water tank is full, but the tank is empty or recently emptied.
False Water Tank Full Indication
Symptom
Dryer display shows unusually long remaining times or time jumps up and down during the cycle.
Moisture Sensing / Time Estimation Issue
Symptom
Dryer does not start at all; display may be blank or lights on but no response when pressing start.
No Power / Won't Start
Symptom
Dryer door will not open at the end of the cycle; no error code displayed.
Door Stuck / Lock Not Releasing
Symptom
Dryer drum does not turn, but the machine powers on and may heat; humming noise may be heard.
Drum Drive Failure
Symptom
Dryer emits a burning smell during operation, with or without visible smoke.
Overheating / Lint Ignition Risk
Symptom
Dryer emits a musty or moldy smell on clothes after drying.
Odor Contamination in Air Path
Symptom
Dryer interior light does not work when the door is opened, but the dryer otherwise functions normally.
Drum Light Failure
Symptom
Dryer is very noisy during operation, with grinding, scraping, or rumbling sounds.
Mechanical Noise / Bearing or Roller Wear
Symptom
Dryer leaks water onto the floor from the front or underneath, no error code displayed.
Water Leakage from Condenser System
Symptom
Dryer runs but clothes remain damp or wet at the end of the cycle, no error code displayed.
Poor Drying Performance / Extended Drying Time
Symptom
Dryer runs but produces no heat; clothes remain cold after the cycle, no error code shown.
No Heat / Cold Drying
Symptom
Dryer stops after a few minutes and clothes are still wet; can be restarted but stops again without code.
Overheating Protection Cycling
Symptom
Dryer stops shortly after start and displays a filter or condenser cleaning symbol, but filters appear clean.
Airflow Restriction Detection
Symptom
Dryer takes multiple cycles to fully dry towels or heavy items, even though it eventually gets them dry.
Reduced Heating Efficiency
Symptom
Dryer vibrates excessively or moves across the floor during operation.
Excessive Vibration / Imbalance
Symptom
Dryer water tank fills very quickly or overflows, even with small loads.
Abnormal Condensate Collection
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E10 |
Dryer will not start a cycle or stops shortly after start; sometimes displays E10 shortly after pressing start.
|
Water Inlet / Condenser Rinsing System Fault | View Details |
| E20 |
Dryer stops mid-cycle, clothes still damp, may display E20 and sometimes water remains in the base tray (for condenser/heat pump models).
|
Drain / Condensate Pump Fault | View Details |
| E21 |
Dryer stops with E21, often shortly after start; may not pump out condensate water and may trigger leak tray float switch on some models.
|
Condensate Pump Blocked or Jammed | View Details |
| E30 |
Dryer will not start or stops and displays E30; sometimes accompanied by a beeping alarm and water in the base tray.
|
Leakage / Anti-Flood System Activated | View Details |
| E40 |
Dryer does not start; display shows E40 or a door symbol; door may appear closed but cycle will not begin.
|
Door Lock / Door Switch Fault | View Details |
| E41 |
Dryer displays E41 and will not start; door appears closed but machine thinks it is open.
|
Door Not Properly Closed Signal | View Details |
| E42 |
Dryer shows E42; door may remain locked or unlocked incorrectly; cycle may not start or may stop unexpectedly.
|
Door Locking Circuit Fault | View Details |
| E50 |
Dryer drum does not turn or stops during cycle; E50 or related motor error appears on display.
|
Motor / Motor Control Fault | View Details |
| E51 |
Dryer will not start drum rotation; E51 displayed; sometimes trips household breaker when attempting to start.
|
Motor Triac Short-Circuit on Control Board | View Details |
| E52 |
Dryer may start but stops shortly after; E52 displayed; drum movement may be erratic.
|
Motor Tachometer Signal Fault | View Details |
| E53 |
Dryer may not start or may stop with E53; sometimes associated with erratic motor speed.
|
Motor Control Circuit Fault | View Details |
| E54 |
Dryer may trip the breaker or show E54 when starting or reversing drum direction.
|
Motor Relay Stuck or Faulty | View Details |
| E60 |
Dryer does not heat or stops with E60; clothes remain cold and wet even after full cycle.
|
Heating System General Fault | View Details |
| E61 |
Dryer heats up very slowly; drying times are excessively long; E61 may be stored as a service code.
|
Insufficient Heating Performance | View Details |
| E62 |
Dryer overheats quickly; drum and door become very hot; cycle may stop with E62.
|
Overheating / Over-Temperature Fault | View Details |
| E63 |
Dryer stops heating mid-cycle; E63 displayed; may restart after cooling down.
|
Heater Safety Cut-Out / Overheat Protection Activated | View Details |
| E64 |
Dryer runs but never heats; E64 stored or displayed; clothes remain cold.
|
Heater Relay or Heater Circuit Open | View Details |
| E70 |
Dryer may not heat correctly; E70 or related sensor error stored; temperature readings appear incorrect.
|
NTC Temperature Sensor Circuit Fault | View Details |
| E71 |
Dryer may not start heating; E71 displayed or logged; control detects NTC out of range (open circuit).
|
NTC Sensor Open-Circuit | View Details |
| E72 |
Dryer may overheat or underheat; E72 logged; second NTC sensor (if fitted) out of range.
|
Secondary NTC Sensor Fault | View Details |
| E80 |
Dryer display or selector behaves erratically; E80 or similar appears; wrong program may be detected.
|
Program Selector / User Interface Fault | View Details |
| E90 |
Dryer will not start; E90 or related communication error appears; display may be blank or frozen.
|
Communication Error Between Main Board and User Interface | View Details |
| E91 |
Dryer display may light but controls are unresponsive; E91 logged as communication error.
|
No Communication from User Interface | View Details |
| E92 |
Dryer may start with wrong configuration; E92 logged; unusual behavior after board replacement.
|
Configuration / EEPROM Error | View Details |
| E93 |
Dryer shows configuration error after service; some programs missing or not working.
|
Incorrect Configuration Data | View Details |
| E94 |
Dryer may not start or may run incorrect cycles; E94 stored; configuration mismatch.
|
Program Configuration Error | View Details |
| – |
Dryer control panel buttons are unresponsive or only some buttons work intermittently.
|
User Interface Keypad Fault | View Details |
| – |
Dryer display shows that the water tank is full, but the tank is empty or recently emptied.
|
False Water Tank Full Indication | View Details |
| – |
Dryer display shows unusually long remaining times or time jumps up and down during the cycle.
|
Moisture Sensing / Time Estimation Issue | View Details |
| – |
Dryer does not start at all; display may be blank or lights on but no response when pressing start.
|
No Power / Won't Start | View Details |
| – |
Dryer door will not open at the end of the cycle; no error code displayed.
|
Door Stuck / Lock Not Releasing | View Details |
| – |
Dryer drum does not turn, but the machine powers on and may heat; humming noise may be heard.
|
Drum Drive Failure | View Details |
| – |
Dryer emits a burning smell during operation, with or without visible smoke.
|
Overheating / Lint Ignition Risk | View Details |
| – |
Dryer emits a musty or moldy smell on clothes after drying.
|
Odor Contamination in Air Path | View Details |
| – |
Dryer interior light does not work when the door is opened, but the dryer otherwise functions normally.
|
Drum Light Failure | View Details |
| – |
Dryer is very noisy during operation, with grinding, scraping, or rumbling sounds.
|
Mechanical Noise / Bearing or Roller Wear | View Details |
| – |
Dryer leaks water onto the floor from the front or underneath, no error code displayed.
|
Water Leakage from Condenser System | View Details |
| – |
Dryer runs but clothes remain damp or wet at the end of the cycle, no error code displayed.
|
Poor Drying Performance / Extended Drying Time | View Details |
| – |
Dryer runs but produces no heat; clothes remain cold after the cycle, no error code shown.
|
No Heat / Cold Drying | View Details |
| – |
Dryer stops after a few minutes and clothes are still wet; can be restarted but stops again without code.
|
Overheating Protection Cycling | View Details |
| – |
Dryer stops shortly after start and displays a filter or condenser cleaning symbol, but filters appear clean.
|
Airflow Restriction Detection | View Details |
| – |
Dryer takes multiple cycles to fully dry towels or heavy items, even though it eventually gets them dry.
|
Reduced Heating Efficiency | View Details |
| – |
Dryer vibrates excessively or moves across the floor during operation.
|
Excessive Vibration / Imbalance | View Details |
| – |
Dryer water tank fills very quickly or overflows, even with small loads.
|
Abnormal Condensate Collection | View Details |
No matching codes found