Aprilaire Humidifiers & Dehumidifiers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
CL
Aprilaire dehumidifier control displays CL and unit will not dehumidify
Control Lockout / Child Lock Enabled
E1
Aprilaire digital humidifier control displays E1 and humidifier will not run
Outdoor Temperature Sensor Open or Shorted
E1
Aprilaire whole-home dehumidifier (e.g., models 1830, 1850, 1870) displays E1 on the onboard control
Return Air Temperature Sensor Fault
E2
Aprilaire digital humidifier control shows E2 and humidifier does not operate automatically
Indoor Temperature Sensor Fault
E2
Aprilaire whole-home dehumidifier displays E2 and will not run
Supply Air Temperature Sensor Fault
E3
Aprilaire dehumidifier shows E3 and shuts down
Refrigeration System High Temperature / Coil Overheat Fault
E3
Aprilaire digital humidifier control displays E3 and humidifier will not run in automatic mode
Relative Humidity Sensor Fault
E4
Aprilaire dehumidifier displays E4 and will not start the compressor
Low Temperature / Coil Freeze Protection Fault
E4
Aprilaire digital humidifier control shows E4 and humidifier does not respond to call for humidity
Control Internal Fault / EEPROM Error
E5
Aprilaire dehumidifier shows E5 and stops running
Float Switch / Condensate Overflow Fault
E5
Aprilaire digital humidifier control displays E5 and humidifier will not energize the solenoid valve
Humidifier Output Circuit Fault
E6
Aprilaire dehumidifier displays E6 and will not respond to wall control
Communication Error Between Dehumidifier and Remote Wall Control
E6
Aprilaire digital humidifier control shows E6 and humidifier does not run when furnace is on
Furnace Interlock / Airflow Proving Fault
E7
Aprilaire dehumidifier shows E7 and shuts down
Internal Control Board Fault
E7
Aprilaire digital humidifier control displays E7 and humidifier runs erratically or not at all
Water Panel / Service Interval Lockout (Some Models)
F1
Aprilaire dehumidifier displays F1 and will not start compressor
High Refrigerant Pressure / High Head Pressure Fault
F2
Aprilaire dehumidifier shows F2 and cycles off quickly
Low Refrigerant Pressure / Low Suction Pressure Fault
HI
Aprilaire dehumidifier display shows HI and runs continuously
High Humidity Indication / Sensor at Upper Limit
LO
Aprilaire dehumidifier display shows LO and unit does not dehumidify
Low Ambient Temperature Lockout
Symptom
Aprilaire bypass humidifier does not produce any moisture even though furnace is running
No Water Flow to Humidifier
Symptom
Aprilaire dehumidifier coils freeze up during operation
Evaporator Coil Icing
Symptom
Aprilaire dehumidifier display is blank but outlet has power
Control Power Failure
Symptom
Aprilaire dehumidifier does not drain properly when connected to a condensate pump
Improper Condensate Pump Integration
Symptom
Aprilaire dehumidifier fan runs but compressor never starts
Compressor Start Circuit Failure
Symptom
Aprilaire dehumidifier is very loud or vibrating excessively
Mechanical Vibration / Mounting Issue
Symptom
Aprilaire dehumidifier runs but does not remove moisture (air feels unchanged, bucket or drain is dry)
Loss of Dehumidification Capacity
Symptom
Aprilaire dehumidifier short cycles (turns on and off frequently)
Short Cycling Control or Refrigeration Issue
Symptom
Aprilaire dehumidifier trips circuit breaker or blows fuse when starting
Electrical Overload / Short Circuit
Symptom
Aprilaire humidifier bypass duct is sweating or dripping water
Condensation on Bypass Duct
Symptom
Aprilaire humidifier causes condensation on windows and walls
Over-Humidification / Control Misadjustment
Symptom
Aprilaire humidifier continues running even when humidity setpoint is reached
Humidistat Stuck Closed or Miscalibrated
Symptom
Aprilaire humidifier does not turn on at all (no click, no water, no fan)
No Power to Humidifier Control Circuit
Symptom
Aprilaire humidifier fan (on fan-powered models) is noisy, rattling, or squealing
Humidifier Fan Motor or Wheel Failure
Symptom
Aprilaire humidifier makes loud banging or water hammer noise when turning on or off
Water Hammer in Supply Line
Symptom
Aprilaire humidifier runs but home humidity stays low
Insufficient Humidification Capacity
Symptom
Aprilaire humidifier water panel scales up very quickly (within weeks)
Excessive Mineral Deposition
Symptom
Musty or moldy odor coming from Aprilaire dehumidifier or humidifier
Biological Growth in Water or Condensate System
Symptom
Water leaking from Aprilaire humidifier onto furnace or floor
Humidifier Drainage Failure / Overflow