GE

GE Ice Makers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E0
GE undercounter ice maker displays E0 and stops making ice or will not start a cycle.
Control Board Communication Fault
E1
GE ice maker shows E1 and stops ice production; unit may power on but not run the compressor or water system.
Evaporator Thermistor Failure
E2
GE ice maker displays E2 and shuts down or fails to complete a freeze cycle.
Bin Thermistor or Ice Level Sensor Fault
E3
GE ice maker shows E3 and will not harvest ice or stops mid-cycle.
Harvest Motor or Harvest Position Switch Fault
E4
GE ice maker displays E4 and may stop cooling or shut down the compressor.
Condenser Temperature Sensor Fault
E5
GE ice maker shows E5 and ice production stops; unit may run briefly then shut down.
High Temperature or Overheat Protection Trip
E6
GE ice maker displays E6 and does not fill with water or stops mid-cycle.
Water Inlet Valve or Water Flow Fault
E7
GE ice maker shows E7 and the compressor does not start or runs briefly then shuts off.
Compressor Start Circuit or Overload Fault
E8
GE ice maker displays E8 and ice production is halted; unit may be stuck in defrost or harvest.
Defrost Sensor or Heater Circuit Fault (for models with hot gas or electric defrost)
E9
GE ice maker shows E9 and may continuously run water or fail to sense ice thickness.
Ice Thickness Sensor or Water Level Sensor Fault
F1
GE ice maker with digital display shows F1 and will not start a cycle.
User Interface Keypad or Touch Control Fault
F2
GE ice maker shows F2 and may shut down or run erratically.
Main Control Board Failure
F3
GE ice maker displays F3 and may not sense bin full or may stop making ice prematurely.
Ice Bin Full Sensor Fault
F4
GE ice maker shows F4 and the unit may not cool properly or may shut down intermittently.
Ambient Temperature Sensor Fault
F5
GE ice maker displays F5 and may not circulate water over the evaporator.
Circulation Pump Fault
F6
GE ice maker shows F6 and may not drain water from the reservoir or bin.
Drain Pump or Gravity Drain Fault
F7
GE ice maker displays F7 and may shut down with a fan-related error.
Evaporator Fan Motor Fault
F8
GE ice maker shows F8 and may indicate a low water or no water condition.
Low Water Level or Float Switch Fault
F9
GE ice maker displays F9 and may indicate a communication or configuration error.
Configuration or EEPROM Fault
H1
GE ice maker shows H1 and stops making ice; may indicate high temperature in ice-making compartment.
High Compartment Temperature Fault
H2
GE ice maker displays H2 and may shut down due to excessively low temperature or sensor error.
Low Temperature or Sensor Out-of-Range Fault
Symptom
GE ice maker cycles on and off frequently without completing full ice cycles.
Short Cycling – Control or Sensor Issue
Symptom
GE ice maker display is on but buttons do not respond or respond intermittently.
Unresponsive User Interface
Symptom
GE ice maker door or bin lid difficult to close or does not seal properly.
Door Alignment or Gasket Issue
Symptom
GE ice maker forms ice but does not release it into the bin (ice stuck on evaporator or grid).
Harvest Failure – Release Mechanism
Symptom
GE ice maker frequently freezes up with heavy ice buildup around the evaporator or fan.
Chronic Icing or Defrost Problem
Symptom
GE ice maker ice bin overfilling; ice spills out even though unit should stop when full.
Bin Full Shutoff Failure
Symptom
GE ice maker interior light not working, but unit otherwise operates normally.
Failed Bin or Cabinet Light
Symptom
GE ice maker is making ice, but the ice cubes are very small or hollow.
Insufficient Water Fill or Premature Harvest
Symptom
GE ice maker leaking water inside the bin, causing ice to clump together.
Internal Drip or Splash Leak
Symptom
GE ice maker leaking water onto the floor from the back or underneath.
External Leak – Tubing or Fittings
Symptom
GE ice maker making a high-pitched squeal or chirping noise.
Fan Motor or Pump Bearing Wear
Symptom
GE ice maker making very loud grinding or rattling noises during operation.
Mechanical Noise – Fan or Pump
Symptom
GE ice maker not filling with water; unit runs but evaporator remains dry.
No Water Fill
Symptom
GE ice maker not making any ice at all; power light may be on but no ice is produced.
No Ice Production – General Failure
Symptom
GE ice maker overflows water into the bin or leaks water from the front.
Overfill or Drainage Failure
Symptom
GE ice maker producing cloudy ice or ice with white flakes.
Mineral Deposits or Air Entrapment
Symptom
GE ice maker producing ice with a bad taste or odor.
Contaminated Water Path or Storage Bin
Symptom
GE ice maker runs continuously but makes very little or no ice; evaporator may not frost properly.
Refrigeration System Underperformance
Symptom
GE ice maker stops making ice even though the bin is not full.
False Bin Full Detection
Symptom
GE ice maker vibrating excessively or making a loud humming noise.
Vibration or Mounting Issue
Symptom
GE ice maker will not power on at all; no lights or sounds.
No Power – Electrical Supply or Internal Fuse
Symptom
GE nugget ice maker producing very wet, slushy ice instead of firm nuggets.
Poor Ice Compression or Excessive Melt
Advertisements