Fagor Microwaves Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E01
Microwave will not start; display works but pressing START does nothing or beeps and shows E01.
Door Interlock Circuit Fault
E02
Microwave stops shortly after pressing START and displays E02; sometimes will not start at all.
Thermal Protection / Overheat Fault
E03
Microwave runs for 1–2 seconds then stops and shows E03 on the display.
Inverter / High-Voltage Power Supply Fault
E04
Microwave display shows E04 and unit will not heat; fan and light may still operate.
Magnetron / Heating Circuit Failure
E05
Microwave beeps and displays E05; cooking does not start or stops immediately.
Touch Control Panel / Keypad Error
E06
Microwave shows E06 and may run the fan but will not heat or start a normal cycle.
Cavity Temperature Sensor (NTC) Fault
E07
Microwave displays E07 and stops; grill or convection functions may be disabled.
Grill / Convection Heater Overheat or Open Circuit
E08
Microwave shows E08 and will not start; sometimes accompanied by a humming noise before stopping.
Turntable Motor / Rotation Feedback Error
E09
Microwave displays E09 and may shut down mid-cycle; sometimes accompanied by flickering display.
Low Line Voltage / Power Supply Error
E10
Microwave shows E10 and beeps; door appears closed but unit refuses to start.
Door Latch Mechanism Misalignment
E11
Microwave displays E11 and convection or combination modes do not start.
Convection Fan Motor Fault
E12
Microwave shows E12 and the interior light and fan may run, but no heating occurs in any mode.
Relay / Triac Control Failure
E13
Microwave displays E13 and may shut down unexpectedly during long cooking cycles.
Cooling Fan / Airflow Fault
E14
Microwave shows E14 and the clock or display behaves erratically; unit may reset during cooking.
Control Board Low-Voltage Regulation Error
E15
Microwave displays E15 and refuses to start; child lock may appear to be stuck on.
Child Lock / Safety Logic Error
Symptom
Microwave cavity fills with excessive steam or condensation, with water droplets forming on the door and walls.
Condensation / Ventilation Issue
Symptom
Microwave clock resets to 0:00 or flashes after every use or randomly during the day.
Intermittent Power or Control Board Memory Loss
Symptom
Microwave convection or grill function does not reach or maintain set temperature; food undercooked in these modes.
Underheating in Grill/Convection Mode
Symptom
Microwave display is dim, flickering, or segments are missing, but cooking still works.
Display Module / VFD/LED Failure
Symptom
Microwave display works but pressing START does nothing; no relay click, no fan or light.
Start Circuit / Control Input Failure
Symptom
Microwave does not start at all; display is blank and no lights or sounds when door is opened.
No Power – Primary Supply Failure
Symptom
Microwave door does not stay closed or pops open during cooking.
Door Latch Retention Failure
Symptom
Microwave door will not open or is very hard to open after cooking.
Door Latch / Release Mechanism Jammed
Symptom
Microwave emits a burning or electrical smell during or after operation.
Overheating Component or Wiring Insulation Failure
Symptom
Microwave emits unusual high-pitched squealing or chirping noise during operation.
Fan or Motor Bearing Wear
Symptom
Microwave exterior (top or side) becomes excessively hot to the touch during normal use.
Inadequate Ventilation / Overheating Cabinet
Symptom
Microwave interior light does not come on when door opens or during cooking, but unit heats normally.
Cavity Lamp Failure
Symptom
Microwave is excessively noisy during operation, with a loud fan or vibration sound.
Cooling Fan or Casing Vibration
Symptom
Microwave keypad buttons are unresponsive or require very hard pressing.
Membrane Keypad Wear
Symptom
Microwave leaks water or condensation onto the countertop or inside the cabinet (built-in models).
Condensate Drainage / Seal Issue
Symptom
Microwave light, fan, and turntable run when door is closed, even without pressing START.
Door Switch Stuck / Shorted
Symptom
Microwave makes loud buzzing or humming noise when running, louder than usual, with reduced or no heating.
High-Voltage Transformer or Magnetron Noise
Symptom
Microwave makes rattling or grinding noises during operation, especially when the turntable rotates.
Mechanical Vibration / Turntable Support Noise
Symptom
Microwave overcooks or burns food quickly even when correct time and power are selected.
Power Regulation / Sensor Control Fault
Symptom
Microwave runs but does not heat food; turntable, light, and fan operate normally with no error code.
No Heating – High-Voltage Circuit Failure
Symptom
Microwave runs with the door open (light, fan, or turntable operate when door is not fully closed).
Door Interlock Safety Failure
Symptom
Microwave sensor-cook or auto-reheat programs stop too early or run too long, giving poor results.
Humidity / Sensor Cooking Fault
Symptom
Microwave sparks or arcs inside the cavity during cooking, especially near the walls or rack.
Cavity Arcing / Waveguide Contamination
Symptom
Microwave trips the household circuit breaker or blows a fuse when starting.
Short Circuit or Overcurrent on Startup
Symptom
Microwave turntable does not rotate, but heating still occurs.
Turntable Drive Failure
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E01 |
Microwave will not start; display works but pressing START does nothing or beeps and shows E01.
|
Door Interlock Circuit Fault | View Details |
| E02 |
Microwave stops shortly after pressing START and displays E02; sometimes will not start at all.
|
Thermal Protection / Overheat Fault | View Details |
| E03 |
Microwave runs for 1–2 seconds then stops and shows E03 on the display.
|
Inverter / High-Voltage Power Supply Fault | View Details |
| E04 |
Microwave display shows E04 and unit will not heat; fan and light may still operate.
|
Magnetron / Heating Circuit Failure | View Details |
| E05 |
Microwave beeps and displays E05; cooking does not start or stops immediately.
|
Touch Control Panel / Keypad Error | View Details |
| E06 |
Microwave shows E06 and may run the fan but will not heat or start a normal cycle.
|
Cavity Temperature Sensor (NTC) Fault | View Details |
| E07 |
Microwave displays E07 and stops; grill or convection functions may be disabled.
|
Grill / Convection Heater Overheat or Open Circuit | View Details |
| E08 |
Microwave shows E08 and will not start; sometimes accompanied by a humming noise before stopping.
|
Turntable Motor / Rotation Feedback Error | View Details |
| E09 |
Microwave displays E09 and may shut down mid-cycle; sometimes accompanied by flickering display.
|
Low Line Voltage / Power Supply Error | View Details |
| E10 |
Microwave shows E10 and beeps; door appears closed but unit refuses to start.
|
Door Latch Mechanism Misalignment | View Details |
| E11 |
Microwave displays E11 and convection or combination modes do not start.
|
Convection Fan Motor Fault | View Details |
| E12 |
Microwave shows E12 and the interior light and fan may run, but no heating occurs in any mode.
|
Relay / Triac Control Failure | View Details |
| E13 |
Microwave displays E13 and may shut down unexpectedly during long cooking cycles.
|
Cooling Fan / Airflow Fault | View Details |
| E14 |
Microwave shows E14 and the clock or display behaves erratically; unit may reset during cooking.
|
Control Board Low-Voltage Regulation Error | View Details |
| E15 |
Microwave displays E15 and refuses to start; child lock may appear to be stuck on.
|
Child Lock / Safety Logic Error | View Details |
| – |
Microwave cavity fills with excessive steam or condensation, with water droplets forming on the door and walls.
|
Condensation / Ventilation Issue | View Details |
| – |
Microwave clock resets to 0:00 or flashes after every use or randomly during the day.
|
Intermittent Power or Control Board Memory Loss | View Details |
| – |
Microwave convection or grill function does not reach or maintain set temperature; food undercooked in these modes.
|
Underheating in Grill/Convection Mode | View Details |
| – |
Microwave display is dim, flickering, or segments are missing, but cooking still works.
|
Display Module / VFD/LED Failure | View Details |
| – |
Microwave display works but pressing START does nothing; no relay click, no fan or light.
|
Start Circuit / Control Input Failure | View Details |
| – |
Microwave does not start at all; display is blank and no lights or sounds when door is opened.
|
No Power – Primary Supply Failure | View Details |
| – |
Microwave door does not stay closed or pops open during cooking.
|
Door Latch Retention Failure | View Details |
| – |
Microwave door will not open or is very hard to open after cooking.
|
Door Latch / Release Mechanism Jammed | View Details |
| – |
Microwave emits a burning or electrical smell during or after operation.
|
Overheating Component or Wiring Insulation Failure | View Details |
| – |
Microwave emits unusual high-pitched squealing or chirping noise during operation.
|
Fan or Motor Bearing Wear | View Details |
| – |
Microwave exterior (top or side) becomes excessively hot to the touch during normal use.
|
Inadequate Ventilation / Overheating Cabinet | View Details |
| – |
Microwave interior light does not come on when door opens or during cooking, but unit heats normally.
|
Cavity Lamp Failure | View Details |
| – |
Microwave is excessively noisy during operation, with a loud fan or vibration sound.
|
Cooling Fan or Casing Vibration | View Details |
| – |
Microwave keypad buttons are unresponsive or require very hard pressing.
|
Membrane Keypad Wear | View Details |
| – |
Microwave leaks water or condensation onto the countertop or inside the cabinet (built-in models).
|
Condensate Drainage / Seal Issue | View Details |
| – |
Microwave light, fan, and turntable run when door is closed, even without pressing START.
|
Door Switch Stuck / Shorted | View Details |
| – |
Microwave makes loud buzzing or humming noise when running, louder than usual, with reduced or no heating.
|
High-Voltage Transformer or Magnetron Noise | View Details |
| – |
Microwave makes rattling or grinding noises during operation, especially when the turntable rotates.
|
Mechanical Vibration / Turntable Support Noise | View Details |
| – |
Microwave overcooks or burns food quickly even when correct time and power are selected.
|
Power Regulation / Sensor Control Fault | View Details |
| – |
Microwave runs but does not heat food; turntable, light, and fan operate normally with no error code.
|
No Heating – High-Voltage Circuit Failure | View Details |
| – |
Microwave runs with the door open (light, fan, or turntable operate when door is not fully closed).
|
Door Interlock Safety Failure | View Details |
| – |
Microwave sensor-cook or auto-reheat programs stop too early or run too long, giving poor results.
|
Humidity / Sensor Cooking Fault | View Details |
| – |
Microwave sparks or arcs inside the cavity during cooking, especially near the walls or rack.
|
Cavity Arcing / Waveguide Contamination | View Details |
| – |
Microwave trips the household circuit breaker or blows a fuse when starting.
|
Short Circuit or Overcurrent on Startup | View Details |
| – |
Microwave turntable does not rotate, but heating still occurs.
|
Turntable Drive Failure | View Details |
No matching codes found
Advertisements