CAT

CAT Standby Generators Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E-01
Generator will not start, controller displays E-01 and inhibits crank
Emergency Stop Active / E-Stop Circuit Open
E-02
Generator cranks but does not start, controller shows E-02
Low Fuel Pressure / Fuel Supply Fault
E-03
Generator shuts down shortly after start, E-03 displayed
Low Oil Pressure Shutdown
E-04
Generator will not crank, controller shows E-04
Low Battery Voltage / Battery Under-Voltage Lockout
E-05
Generator cranks but fails to start, E-05 displayed on controller
Overcrank / Failed to Start
E-06
Generator shuts down during run, controller shows E-06
High Engine Coolant Temperature Shutdown
E-07
Generator shuts down, controller displays E-07
Overspeed Shutdown
E-08
Generator shuts down, E-08 displayed, no AC output to load
Underspeed / Underfrequency Shutdown
E-09
Generator shuts down, controller shows E-09, engine temperature normal
High Exhaust Temperature / Turbocharger Overheat
E-10
Generator shuts down, controller displays E-10, oil level appears normal
Low Oil Level / Oil Level Sensor Fault
E-11
Generator shuts down, controller shows E-11, coolant level normal
Low Coolant Level Sensor Fault / Coolant Loss
E-12
Generator will not transfer load, controller shows E-12
Generator Undervoltage / Low Output Voltage
E-13
Generator trips on E-13, load drops, controller indicates overvoltage
Generator Overvoltage
E-14
Generator shuts down, controller shows E-14, no obvious engine issue
Generator Overcurrent / Overload Trip
E-15
Controller displays E-15, generator will not start automatically
Remote Start Signal Fault / ATS Communication Error
E-16
Controller shows E-16, engine stops, no other obvious alarms
Emergency Shutdown Input Active (External Fault)
E-17
Controller displays E-17, no engine crank when start is commanded
Starter Circuit Fault / Crank Relay Failure
E-18
Controller shows E-18, generator runs but alarms, possible sensor issues
Analog Sensor Out of Range / Sensor Calibration Fault
E-19
Controller displays E-19, generator will not start, fuel tank is full
Fuel Level Sensor Fault / High or Low Fuel Alarm
E-20
Controller shows E-20, generator stops, no obvious mechanical problem
Controller Internal Fault / Memory Error
Symptom
Corrosion and rust visible on generator frame, fuel tank, and electrical connections
Environmental Corrosion / Moisture Ingress
Symptom
Generator battery repeatedly goes dead between exercise cycles
Chronic Battery Discharge / Charging System Issue
Symptom
Generator controller display is blank or unreadable, unit otherwise appears intact
Controller Power Loss / Display Failure
Symptom
Generator emits blue smoke and consumes engine oil
Oil Burning / Internal Engine Wear
Symptom
Generator emits visible black smoke from the exhaust during operation
Rich Fuel Mixture / Incomplete Combustion
Symptom
Generator emits white smoke, especially on startup, and runs rough
Incomplete Combustion / Coolant or Fuel Issue
Symptom
Generator enclosure fills with rodents or insects, causing chewed wires and nests
Pest Intrusion / Wiring Damage
Symptom
Generator enclosure is very hot to the touch, components show heat discoloration
Inadequate Ventilation / Cooling Airflow Restriction
Symptom
Generator fails to start automatically during a utility outage but starts manually
Auto Start Logic / Scheduling Fault
Symptom
Generator is excessively noisy during operation compared to normal
Abnormal Mechanical Noise / Exhaust or Engine Mount Issue
Symptom
Generator runs but frequency is low or high (not 50/60 Hz as expected)
Incorrect Engine Speed / Governor Misadjustment
Symptom
Generator runs but house lights flicker and some equipment resets intermittently
Unstable Voltage / Poor Voltage Regulation
Symptom
Generator starts and runs but does not transfer power to the house or building
Automatic Transfer Switch (ATS) Fails to Transfer
Symptom
Generator starts and runs only during exercise but not during real power outages
ATS Sensing or Logic Fault
Symptom
Generator starts and then immediately shuts down without any code on a basic panel
Run Relay or Fuel Solenoid Drops Out
Symptom
Generator vibrates excessively, causing enclosure panels to rattle
Excessive Vibration / Misalignment
Symptom
Strong fuel smell around the generator during or after operation
Fuel Leak / Fuel System Integrity Issue
Symptom
Visible oil leak under or around the generator set
Engine Oil Leak