Viessmann

Viessmann Water Softeners Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
bP
Display shows 'bP' or similar and unit indicates bypass mode
Bypass Mode Active
E1
Display shows E1 and backlight flashes, softener unresponsive
General Controller Communication Error
E2
Display shows E2 and unit cannot be programmed
Keypad / Button Fault
E3
Display shows E3 and unit indicates sensor bus error (for models with multiple sensors)
Sensor Bus Communication Fault
E4
Display shows E4 and unit reports power supply error
Low Voltage / Power Supply Fault
E5
Display shows E5 and unit indicates configuration mismatch
Configuration / Model Mismatch Fault
F1
Display shows F1 and softener does not regenerate automatically
Flow Sensor Signal Fault
F10
Display shows F10 and no salt consumption is observed over time
Brine System Not Operating
F11
Display shows F11 and water remains hard even after regeneration
Resin Capacity / Exhaustion Fault
F12
Display shows F12 and unit reports low salt even when tank is full
Salt Level Sensor Fault
F13
Display shows F13 and unit will not enter regeneration when commanded
Regeneration Start Inhibit / Safety Interlock Fault
F14
Display shows F14 and unit indicates sensor temperature error
Temperature Sensor Fault
F15
Display shows F15 and unit reports internal memory error
EEPROM / Configuration Memory Fault
F2
Display shows F2 and regeneration stops shortly after starting
Brine Tank Level / Brine Draw Fault
F3
Display shows F3 and unit remains in service mode without regenerating
Motor / Valve Drive Fault
F4
Display shows F4 and softener is stuck in one regeneration step
Position Switch / Encoder Fault
F5
Display shows F5 and no water is delivered through the softener
Inlet / Outlet Pressure or Flow Fault
F6
Display shows F6 and unit does not count down remaining capacity correctly
Metering / Volume Calculation Fault
F7
Display shows F7 and regeneration does not start at the programmed time
Real-Time Clock / Timer Fault
F8
Display shows F8 and unit aborts regeneration with an alarm
Drain Line / Backwash Flow Fault
F9
Display shows F9 and softener remains in regeneration indefinitely
Regeneration Step Timeout
Lo
Display shows 'Lo' or low salt icon and audible alarm sounds
Low Salt Level Warning
Symptom
Brine tank overfills with water after regeneration
Brine Refill / Float Valve Malfunction
Symptom
Brine tank remains dry; no water in bottom even after refill stage
No Brine Refill
Symptom
Display is on but unresponsive or frozen; buttons do not work
Controller Freeze / User Interface Lockup
Symptom
Loud banging or knocking noises in pipes when the softener regenerates
Water Hammer During Regeneration
Symptom
Softener causes low water pressure in the house during normal operation
Flow Restriction Through Softener
Symptom
Softener causes noticeable vibration and rattling in nearby pipes during regeneration
Hydraulic Vibration / Flow Pulsation
Symptom
Softener causes very low or no water flow during regeneration
Regeneration Flow Restriction
Symptom
Softener display backlight flickers or dims intermittently
Unstable Low-Voltage Supply
Symptom
Softener does not regenerate at all, but no error codes are displayed
Regeneration Not Initiating
Symptom
Softener emits a foul or musty odor from the brine tank
Biological Growth in Brine Tank
Symptom
Softener emits a persistent humming noise even when not regenerating
Transformer / Motor Hum
Symptom
Softener emits a plastic or burning smell from the control head area
Overheating Electrical Component
Symptom
Softener frequently loses time and settings after short power outages
Backup Power / Memory Retention Failure
Symptom
Softener makes grinding or clicking noises from the valve head during operation
Valve Motor / Gear Train Wear
Symptom
Softener produces cloudy or discolored water after regeneration
Resin or Sediment Discharge
Symptom
Softener produces salty-tasting water immediately after regeneration
Excessive Brine Carryover
Symptom
Softener regenerates too frequently, causing excessive salt and water consumption
Over-Regeneration / Incorrect Programming
Symptom
Softener stuck in regeneration; continues cycling water to drain for many hours
Regeneration Not Completing
Symptom
Softener uses no salt over weeks of operation, but no alarms are shown
Brine System Non-Function Without Error
Symptom
Softener will not power on; display is blank
No Power / Dead Control
Symptom
Water remains hard at taps even though the softener appears to run normally (no error code)
Ineffective Softening / Resin Exhaustion
Symptom
Water softener leaks from around the valve head or top cover
Valve Head / O-Ring Leakage
Symptom
Water softener leaks from the brine tank or around the brine well
Brine Tank / Brine Well Leakage
Symptom
Water softener leaks from the drain hose during normal service (not regenerating)
Internal Valve Bypass to Drain
Advertisements