Grundig

Grundig Wine Coolers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E0
Display shows E0 and the interior temperature reading is clearly inaccurate or fluctuates wildly.
Cabinet Temperature Sensor (NTC) Failure
E1
Display shows E1 and the unit does not cool correctly or cycles erratically.
Evaporator Temperature Sensor (NTC) Failure
E10
Display shows E10 and the interior light stays on or never turns on, sometimes accompanied by door alarm issues.
Lighting Circuit or LED Driver Fault
E11
Display shows E11 and the dual-zone wine cooler cannot control one of the zones correctly.
Upper/Lower Zone Temperature Sensor Fault (Dual-Zone Models)
E12
Display shows E12 and the unit emits a continuous or intermittent alarm, often related to high temperature.
High Temperature Alarm / Over-Temperature Protection
E13
Display shows E13 and the unit does not respond to temperature adjustments or mode changes.
EEPROM / Configuration Data Error
E14
Display shows E14 and the compressor cycles rapidly or not at all, with erratic temperature control.
Compressor Temperature Sensor or Overheat Protection Fault
E15
Display shows E15 and the unit may shut down unexpectedly or fail to start after a power interruption.
Power Supply / Low Voltage Fault
E2
Display shows E2 and the ambient temperature reading is incorrect or the unit runs continuously.
Ambient Temperature Sensor (NTC) Failure
E3
Display shows E3 and the defrost cycle does not operate correctly (excessive ice on evaporator).
Defrost Sensor or Defrost Circuit Failure
E4
Display shows E4 and the compressor does not start or stops shortly after starting.
Compressor Start/Overload Protection Fault
E5
Display shows E5 and the fan inside the wine cooler does not run, causing uneven temperatures.
Evaporator Fan Motor Failure
E6
Display shows E6 and the interior light or control panel behaves erratically when the door is opened or closed.
Door Switch or Door Sensor Fault
E7
Display shows E7 and the unit fails to maintain set temperature despite the compressor running.
Condenser Fan or Condenser Temperature Fault
E8
Display shows E8 and the compressor does not run; the unit remains warm.
Compressor Drive or Inverter Fault (if equipped)
E9
Display shows E9 and the unit beeps; temperature cannot be adjusted properly.
Control Panel or Keypad Fault
Symptom
Buzzing or rattling noise from the rear, especially when the compressor is running.
Condenser Fan or Condenser Vibration
Symptom
Cabinet exterior sides feel excessively hot to the touch.
Condenser Heat Dissipation Issue
Symptom
Clicking noise from the compressor area and intermittent starting attempts.
Compressor Start Failure
Symptom
Control panel buttons do not respond or respond intermittently.
User Interface Keypad Failure
Symptom
Display is completely blank, but interior light may still work.
Display Power or UI Failure
Symptom
Display shows temperature but does not change even after many hours of operation.
Sensor Stuck Reading or Control Board Fault
Symptom
Door does not close properly or pops open slightly after being shut.
Door Alignment or Gasket Failure
Symptom
Dual-zone wine cooler has both zones at the same temperature despite different setpoints.
Zone Separation or Damper Failure
Symptom
Excessive condensation on the glass door or inside the cabinet.
Moisture Ingress / Poor Insulation
Symptom
Excessive frost or ice buildup on the evaporator or rear interior wall.
Defrost System Failure or Air Ingress
Symptom
High-pitched whine or grinding noise from inside the cabinet.
Evaporator Fan Bearing Wear
Symptom
Interior light does not turn on when the door is opened, but the unit cools normally.
Interior Lighting Failure
Symptom
Interior light stays on even when the door is closed, causing heating inside the cabinet.
Door Switch Stuck Closed
Symptom
Loud humming, rattling, or vibrating noise during operation.
Mechanical Vibration or Loose Components
Symptom
Strong chemical or burning smell coming from the wine cooler.
Overheating Electrical Component
Symptom
Unit trips the household circuit breaker or RCD when plugged in or shortly after starting.
Electrical Short or Ground Fault
Symptom
Unusual sweet or solvent-like odor and loss of cooling performance.
Refrigerant Leak in Sealed System
Symptom
Water pooling at the bottom of the wine cooler or leaking onto the floor.
Condensate Drain Blockage or Overflow
Symptom
Wine cooler cools but temperature is uneven; top is warmer than bottom or vice versa.
Air Circulation Imbalance
Symptom
Wine cooler not cooling at all; interior is at room temperature, but lights and display work.
Complete Loss of Cooling
Symptom
Wine cooler runs continuously and overcools or cannot reach the set temperature, cycling rarely or not at all.
Thermostat / Temperature Control Miscalibration
Symptom
Wine cooler turns on and off frequently in short cycles.
Short Cycling / Control Instability
Advertisements