Breville

Breville Coffee Makers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
ADD WATER
Breville coffee maker displays ADD WATER even when the tank is full.
Water Level Detection Error
CLEAN ME
Breville espresso machine shows CLEAN ME or a cleaning light and may have slow or uneven flow.
Brew Circuit Contamination / Coffee Oil Buildup
DESCALE
Breville coffee maker displays DESCALE or a flashing descale icon and may reduce brewing or steaming performance.
Scale Buildup in Hydraulic Circuit
EMPTY COFFEE FILTER
Breville drip coffee maker displays EMPTY COFFEE FILTER or beeps when no grounds are detected.
Brew Basket Presence / Load Detection
ER01
Breville espresso machine displays ER01 and will not start a shot or heat properly.
Thermal Fuse / Overheat Protection Trip
ER02
Breville espresso machine shows ER02 and does not heat or brew.
Temperature Sensor (NTC) Failure
ER03
Breville coffee maker displays ER03 and will not brew; pump may not run.
Flow Meter / Water Flow Sensor Error
ER04
Breville espresso machine shows ER04 and stops brewing mid-cycle.
Pump / Pressure System Fault
ER05
Breville coffee maker displays ER05 and will not start; sometimes accompanied by beeping.
Water Reservoir / Level Sensor Fault
ER06
Breville espresso machine shows ER06 and will not steam or brew.
Steam Thermoblock Overheat / Steam Sensor Fault
ER07
Breville espresso machine displays ER07 and the grinder will not run.
Grinder Motor / Hall Sensor Fault
ER08
Breville espresso machine shows ER08 and the brew head does not move or lock (on models with automatic group movement).
Brew Head Drive / Position Error
ER09
Breville espresso machine displays ER09 and immediately stops brewing; sometimes accompanied by water leaking into the drip tray.
3-Way Solenoid Valve / Drain Valve Fault
ER10
Breville espresso machine shows ER10 and will not power up fully or respond to buttons.
Control Board / Firmware Error
FILL TANK
Breville drip coffee maker shows FILL TANK and will not start a brew cycle.
Low Water Detection / Inlet Blockage
GRIND TOO FINE
Breville espresso machine displays GRIND TOO FINE and extraction is slow or stalls.
Excessive Brew Resistance Detected
HIGH PRESSURE
Breville espresso machine displays HIGH PRESSURE or stalls during extraction with little or no flow.
Brew Pressure Too High / Flow Restriction
INSERT PORTAFILTER
Breville espresso machine displays INSERT PORTAFILTER and will not start extraction.
Portafilter Presence / Lock Detection Fault
LOCK BEAN HOPPER
Breville espresso machine displays LOCK BEAN HOPPER and grinder will not run.
Bean Hopper Position / Safety Interlock Fault
LOW PRESSURE
Breville espresso machine displays LOW PRESSURE during extraction and shots run very fast.
Brew Pressure Too Low
NO WATER FLOW
Breville coffee maker displays NO WATER FLOW and stops the brew cycle.
Inlet / Pump Flow Failure
OVER TEMP
Breville coffee maker displays OVER TEMP or overheats and shuts down mid-brew.
Overtemperature Protection Activation
STEAM TIMEOUT
Breville espresso machine shows STEAM TIMEOUT and stops steaming before the milk is fully heated.
Steam Cycle Timeout / Insufficient Steam Production
Symptom
Breville coffee maker hot plate does not heat or keep coffee warm.
Warming Plate Heating Failure
Symptom
Breville coffee maker overflows the filter basket, causing coffee and grounds to spill over.
Brew Basket Drain Restriction / Overfill
Symptom
Breville coffee maker takes much longer than normal to brew a pot of coffee.
Restricted Water Flow / Scale Buildup
Symptom
Breville espresso machine displays inconsistent shot volumes; sometimes too much, sometimes too little.
Inaccurate Flow Meter Readings
Symptom
Breville espresso machine does not heat; water comes out cold or lukewarm.
Brew Heating Failure
Symptom
Breville espresso machine drips water from the group head for a long time after brewing.
3-Way Valve Not Venting Properly
Symptom
Breville espresso machine emits a burning smell during operation.
Overheating Component or Electrical Fault
Symptom
Breville espresso machine grinder does not run at all; no sound when grinding is requested.
Grinder Power / Motor Failure
Symptom
Breville espresso machine grinder runs but no coffee comes out of the chute.
Grinder Chute Blockage
Symptom
Breville espresso machine leaks water from under the machine during or after brewing.
Internal Hose or Fitting Leak
Symptom
Breville espresso machine makes loud rattling or buzzing noises during brewing.
Pump Vibration / Loose Internal Components
Symptom
Breville espresso machine powers on but buttons or touchscreen do not respond.
User Interface / Keypad Failure
Symptom
Breville espresso machine produces very noisy, sputtering steam with large water droplets.
Wet Steam / Condensation in Steam Circuit
Symptom
Breville espresso machine produces very weak coffee or under-extracted shots without any error code.
Under-Extraction / Low Brew Strength
Symptom
Breville espresso machine steam wand drips continuously even when the steam valve is closed.
Leaking Steam Valve
Symptom
Breville espresso machine steam wand is blocked; no steam or hot water comes out.
Blocked Steam Wand / Tip
Symptom
Breville espresso machine will not power on; no lights or display.
No Power / Power Supply Failure
Symptom
Water leaks from around the portafilter during extraction on a Breville espresso machine.
Group Head Gasket Wear / Portafilter Seal Failure
Advertisements