dE
Microwave displays dE and will not start; sometimes clears when door is slammed.
Door Error / Door Not Properly Closed
E1
Microwave will not start; display shows E1 immediately after pressing START.
Door Interlock Switch Fault
E2
Microwave beeps and shows E2 shortly after starting; cooking stops automatically.
Cavity Temperature Sensor / Thermistor Fault
E3
Microwave does not heat and displays E3 within a few seconds of starting.
Magnetron Overheat / Thermal Cut-out Trip
E4
Microwave stops mid-cycle and shows E4; may occur more often on grill or convection modes (if equipped).
Overheat Protection / Top Cavity Thermal Cut-out Fault
E5
Microwave does not heat; display shows E5 shortly after pressing START.
High Voltage System Fault / Inverter or Transformer Error
E6
Microwave display shows E6 and unit will not start; keypad appears unresponsive or erratic.
Keypad / Touch Control Panel Communication Error
E7
Microwave shows E7 and will not start; sometimes accompanied by flickering display.
Low Voltage Power Supply Error
E8
On grill or convection Morphy Richards microwaves, E8 appears and grill/convection will not operate.
Grill / Convection Heater Circuit Fault
E9
Microwave shows E9 and stops heating; fan and light may still operate.
Magnetron Current / Output Monitoring Error
Err
Display shows Err when trying to start or set certain functions; beeping may occur.
General Control Error / Invalid Input
H0
Display shows H0 or 'Ho' and the microwave does not heat; fan may run briefly.
Humidity / Steam Sensor Error (on sensor-cook models)
LOC
Display shows LOC or a lock icon; buttons do not respond and microwave will not start.
Child Lock / Control Lock Activated
SE
Display shows SE (or sometimes '5E') and the microwave beeps continuously; keys may appear stuck.
Keypad Stuck Key / Shorted Membrane
Symptom
Convection oven function does not reach or maintain set temperature (on convection models).
Convection Heating / Temperature Control Fault
Symptom
Grill function does not heat, but microwave heating works normally (on combination models).
Grill Element Circuit Failure
Symptom
Microwave buttons are unresponsive or require very hard pressing to register.
Keypad Wear / Membrane Failure
Symptom
Microwave completely dead: no display, no light, no response when buttons are pressed.
No Power / Dead Appliance
Symptom
Microwave cooks unevenly; some areas of food are cold while others are very hot.
Uneven Heating / Distribution Issue
Symptom
Microwave display is dim, flickering, or some segments are missing.
Display / VFD or LED Module Degradation
Symptom
Microwave display is on and buttons respond, but pressing START does nothing (no relay click, no fan, no light).
Start Circuit / Relay Drive Failure
Symptom
Microwave door does not close properly; it feels loose or misaligned and may cause intermittent operation.
Door Alignment / Hinge Wear
Symptom
Microwave door will not open or is jammed after cooking.
Door Latch Mechanism Jam
Symptom
Microwave emits a burning smell or visible smoke from the vents during or after cooking.
Overheating / Food or Component Burning
Symptom
Microwave emits a strong chemical or plastic smell when first used or after long storage.
Initial Burn-in Odor / Residual Manufacturing Oils
Symptom
Microwave fan continues to run for a long time after cooking has finished.
Cooling Fan Overrun / Thermostat Control
Symptom
Microwave interior light does not come on, but unit heats and operates normally.
Cavity Lamp Failure
Symptom
Microwave interior light stays on even when the door is closed and no cooking is in progress.
Stuck Lamp Circuit / Door Switch Fault
Symptom
Microwave is very noisy during operation (loud humming, rattling, or vibration).
Excessive Operational Noise
Symptom
Microwave leaks water or condensation onto the worktop or from the door area.
Condensation / Drainage Issue
Symptom
Microwave light and fan come on as soon as the door is closed, even without pressing START.
Door Switch / Monitor Switch Miswiring
Symptom
Microwave makes loud grinding or scraping noises when the turntable rotates.
Turntable Mechanical Noise
Symptom
Microwave runs (light on, turntable rotating, fan running) but food does not heat up.
No Heating / Magnetron or High Voltage Failure
Symptom
Microwave time counts down too quickly or too slowly compared to real time.
Timer / Clock Calibration Error
Symptom
Microwave trips the household circuit breaker or blows the fuse when START is pressed.
Short Circuit Under Load
Symptom
Turntable does not rotate during cooking, but microwave heats normally.
Turntable Drive Failure
Symptom
Visible arcing (sparks) inside the cavity, often near the side wall or around the turntable.
Cavity Arcing / Insulation Breakdown