Midea

Midea Freezers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
dF
Display shows dF or DF; freezer may pause cooling periodically
Defrost Mode Indication (Not a Fault on Some Models)
E1
Freezer beeps and displays E1; temperature may not match setpoint
Cabinet Temperature Sensor (NTC) Failure
E2
Freezer displays E2 and may run continuously or not cool correctly
Evaporator Temperature Sensor (NTC) Failure
E3
Freezer shows E3; compressor may not start or may short-cycle
Ambient / Room Temperature Sensor Failure
E4
Freezer displays E4 and may not defrost properly; frost builds up on evaporator
Defrost Sensor / Defrost Thermistor Failure
E5
Freezer shows E5; may not defrost and ice accumulates on evaporator and air ducts
Defrost Heater or Defrost Circuit Failure
E6
Freezer displays E6; compressor may not run or may shut off unexpectedly
Communication Error Between Display Board and Main Control Board
E7
Freezer shows E7; fan may not run, or airflow seems weak; temperature uneven
Evaporator Fan Motor Feedback / Fan Error
E8
Freezer displays E8; compressor may not start or may shut down quickly
Compressor Overload / Start Protection Error
E9
Freezer shows E9; interior light or door alarm may behave erratically
Door Switch / Door Sensor Error
F1
Freezer shows F1; may not respond correctly to temperature adjustments
Control Panel / Keypad Fault
F2
Freezer shows F2; audible alarm may sound continuously
High Temperature Alarm Sensor Fault
F3
Freezer shows F3; may not maintain stable temperature
Thermostat / Temperature Control Fault (Mechanical Models)
F4
Freezer shows F4; compressor may not run even though display appears normal
Compressor Relay / Output Fault
F5
Freezer shows F5; fan and compressor behavior may be erratic
Power Supply / Voltage Error
H1
Display shows H1 or HI; freezer interior is too warm and alarm may sound
High Temperature Alarm Condition
L1
Display shows L1 or LO; freezer temperature is too low, some items may be freezing harder than normal or frost may be excessive
Low Temperature / Overcooling Condition
Symptom
Alarm beeping continuously even though temperature seems normal and door is closed
False Alarm Condition
Symptom
Condenser fan (on models with external condenser fan) not running; compressor very hot
Condenser Fan Motor Failure
Symptom
Control panel buttons unresponsive; cannot change temperature or settings
User Interface Failure
Symptom
Evaporator fan is noisy or squealing; airflow seems reduced
Evaporator Fan Motor Wear or Ice Interference
Symptom
Freezer door difficult to open right after closing; suction effect
Normal Vacuum / Pressure Equalization or Gasket Stickiness
Symptom
Freezer door not sealing; frost forming around door opening
Door Misalignment or Gasket Failure
Symptom
Freezer exterior sides or top feel very hot to the touch
High Cabinet Surface Temperature
Symptom
Freezer interior has water droplets or ice buildup on walls and ceiling
Excess Moisture / Condensation Ingress
Symptom
Freezer interior light stays on when door is closed, causing warming near top
Door Switch Stuck Open
Symptom
Freezer interior liner cracked or damaged; possible frost or moisture in crack area
Inner Liner Damage
Symptom
Freezer interior smells bad or has a strong odor
Odor Contamination
Symptom
Freezer interior too cold; food excessively hard or ice cream rock solid even at moderate setting
Overcooling Due to Control Fault
Symptom
Freezer leaking water onto the floor from underneath
Defrost Drain Blockage or Drain Pan Overflow
Symptom
Freezer makes loud humming, buzzing, or clicking noises
Compressor or Start Device Noise
Symptom
Freezer makes loud rattling or vibrating noise, especially when compressor runs
Cabinet Vibration / Loose Components
Symptom
Freezer not cooling at all; interior warm, compressor not running, lights may still work
Compressor Not Starting
Symptom
Freezer runs but does not get cold enough; compressor and fan run almost continuously
Sealed System Underperformance (Low Refrigerant or Weak Compressor)
Symptom
Freezer runs constantly and forms thick frost on the evaporator cover and shelves
Defrost System Failure
Symptom
Freezer temperature fluctuates widely; sometimes too warm, sometimes too cold
Unstable Temperature Control
Symptom
Freezer trips household breaker or GFCI outlet when it starts
Electrical Short or Ground Fault
Symptom
Freezer will not start at all; no lights, no display, no sound
No Power / Main Supply Failure
Symptom
Frost or ice buildup only on top shelf or in one corner of freezer
Localized Air Leak or Airflow Restriction
Symptom
Interior light not working but freezer otherwise cools normally
Interior Light Circuit Failure