Display shows AUG or auger error; auger stops feeding pellets mid-cook.
Auger Stall or Motor Overload
ERR1
Grilla Grills pellet grill will not ignite; display shows ERR1 shortly after startup, no flame in firepot.
Igniter Rod Failure or Open Igniter Circuit
ERR2
Pellet grill shows ERR2 and shuts down; grill overheats or temperature runs away well above setpoint.
Over-Temperature Shutdown / High-Temp Safety Trip
ERR3
Display shows ERR3 and grill will not start or shuts down; fan and auger may not run.
Combustion Fan or Fan Circuit Failure
ERR4
Grill displays ERR4 and shuts down; auger does not feed pellets during startup.
Auger Motor or Auger Circuit Failure
ERR5
Display shows ERR5; grill will not power up fully or shuts down unexpectedly.
Low Voltage or Power Supply Fault
ERR6
ERR6 displayed; grill temperature reading is extremely low or shows dashes, grill will not heat properly.
Open or Disconnected RTD Temperature Probe
ERR7
ERR7 displayed; grill temperature reading is extremely high or erratic even when grill is cold.
Shorted RTD Temperature Probe or Probe Circuit
FAN
Display shows FAN or fan error; grill will not start or shuts down during cook.
Combustion Fan Speed or Feedback Error
FUSE
Display shows FUSE or grill is completely dead with blown fuse indication.
Main Fuse Blown / Overcurrent Protection Trip
IGN
Display shows IGN or ignition error; grill times out without lighting pellets.
Failed Automatic Ignition Sequence
NOPEL
Display shows NOPEL or low pellet warning; grill shuts down or fails to maintain temperature.
Pellet Starvation / Empty Hopper Condition
P1
Display shows P1 and grill struggles to reach set temperature, especially in cold or windy conditions.
Low Feed Rate / Conservative P-Setting
P5
Display shows P5; grill overshoots set temperature and produces heavy smoke at low settings.
High Feed Rate / Aggressive P-Setting
SEN
Display shows SEN or sensor error; grill will not maintain set temperature.
Temperature Sensor (RTD) Fault
Symptom
Control panel buttons unresponsive or intermittent; cannot change temperature or mode reliably.
Keypad / Control Panel Input Failure
Symptom
Digital temperature display fluctuates wildly (e.g., jumps 50–100°F) without actual temperature change.
Erratic Temperature Reading / Electrical Noise
Symptom
Display is very dim or segments missing, but grill otherwise operates.
Display Module Degradation
Symptom
Excessive vibration or rattling of grill body during operation.
Structural Vibration / Loose Panels
Symptom
Grease fire in cook chamber; flames from drip tray or below grates during cook.
Grease Ignition / Drip Tray Fire
Symptom
Grease leaking from bottom of grill cabinet instead of into grease bucket.
Grease Drainage Failure
Symptom
Grill overshoots set temperature by 50°F or more and struggles to stabilize, especially at low settings.
Temperature Overshoot / Poor Temperature Regulation
Symptom
Grill powers on but will not ignite; pellets feed into firepot but never light, requiring manual lighting.
Weak or Failed Hot Rod Igniter
Symptom
Grill produces excessive white smoke and sooty residue on food; pellets smolder instead of burning cleanly.
Incomplete Combustion / Poor Air-Fuel Mix
Symptom
Grill starts but then goes out mid-cook; fire dies and temperature drops to ambient while controller continues running.
Fire Extinguishing / Flame-Out During Operation
Symptom
Grill struggles to reach or maintain high temperatures (e.g., cannot exceed 350°F) even with lid closed.
Low Maximum Temperature / Insufficient Heat Output
Symptom
Grilla Grills pellet grill will not power on at all; no lights or display.
No Power / Dead Control Board
Symptom
High-pitched squeal or rattling noise from fan area during cook.
Combustion Fan Bearing Wear or Obstruction
Symptom
Loud grinding or squealing noise from hopper area during operation.
Auger Mechanical Noise / Bearing Wear
Symptom
Meat probe temperature reading is inaccurate or does not change during cook.
Faulty Meat Probe or Probe Jack
Symptom
Paint bubbling or peeling on exterior near firebox or exhaust.
High-Heat Paint Failure
Symptom
Pellets backing up into firepot and overflowing, causing large piles of unburned pellets.
Overfeeding / Poor Combustion
Symptom
Pellets not feeding at all from hopper to firepot, but auger motor can be heard running.
Auger Shear Pin Failure or Coupling Slip
Symptom
Rust forming inside cook chamber or on grates despite normal use.
Corrosion of Interior Surfaces
Symptom
Strong smoke smell or smoke leaking heavily from hopper lid during operation.
Backdraft Through Hopper / Poor Exhaust Flow
Symptom
Water intrusion into hopper or cook chamber after rain, causing pellets to swell and jam.
Moisture Ingress / Hopper Water Leak
Symptom
WiFi or app connectivity issues with Grilla Grills controller (if equipped); cannot connect or maintain connection.
Wireless Communication Failure
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| AUG |
Display shows AUG or auger error; auger stops feeding pellets mid-cook.
|
Auger Stall or Motor Overload | View Details |
| ERR1 |
Grilla Grills pellet grill will not ignite; display shows ERR1 shortly after startup, no flame in firepot.
|
Igniter Rod Failure or Open Igniter Circuit | View Details |
| ERR2 |
Pellet grill shows ERR2 and shuts down; grill overheats or temperature runs away well above setpoint.
|
Over-Temperature Shutdown / High-Temp Safety Trip | View Details |
| ERR3 |
Display shows ERR3 and grill will not start or shuts down; fan and auger may not run.
|
Combustion Fan or Fan Circuit Failure | View Details |
| ERR4 |
Grill displays ERR4 and shuts down; auger does not feed pellets during startup.
|
Auger Motor or Auger Circuit Failure | View Details |
| ERR5 |
Display shows ERR5; grill will not power up fully or shuts down unexpectedly.
|
Low Voltage or Power Supply Fault | View Details |
| ERR6 |
ERR6 displayed; grill temperature reading is extremely low or shows dashes, grill will not heat properly.
|
Open or Disconnected RTD Temperature Probe | View Details |
| ERR7 |
ERR7 displayed; grill temperature reading is extremely high or erratic even when grill is cold.
|
Shorted RTD Temperature Probe or Probe Circuit | View Details |
| FAN |
Display shows FAN or fan error; grill will not start or shuts down during cook.
|
Combustion Fan Speed or Feedback Error | View Details |
| FUSE |
Display shows FUSE or grill is completely dead with blown fuse indication.
|
Main Fuse Blown / Overcurrent Protection Trip | View Details |
| IGN |
Display shows IGN or ignition error; grill times out without lighting pellets.
|
Failed Automatic Ignition Sequence | View Details |
| NOPEL |
Display shows NOPEL or low pellet warning; grill shuts down or fails to maintain temperature.
|
Pellet Starvation / Empty Hopper Condition | View Details |
| P1 |
Display shows P1 and grill struggles to reach set temperature, especially in cold or windy conditions.
|
Low Feed Rate / Conservative P-Setting | View Details |
| P5 |
Display shows P5; grill overshoots set temperature and produces heavy smoke at low settings.
|
High Feed Rate / Aggressive P-Setting | View Details |
| SEN |
Display shows SEN or sensor error; grill will not maintain set temperature.
|
Temperature Sensor (RTD) Fault | View Details |
| – |
Control panel buttons unresponsive or intermittent; cannot change temperature or mode reliably.
|
Keypad / Control Panel Input Failure | View Details |
| – |
Digital temperature display fluctuates wildly (e.g., jumps 50–100°F) without actual temperature change.
|
Erratic Temperature Reading / Electrical Noise | View Details |
| – |
Display is very dim or segments missing, but grill otherwise operates.
|
Display Module Degradation | View Details |
| – |
Excessive vibration or rattling of grill body during operation.
|
Structural Vibration / Loose Panels | View Details |
| – |
Grease fire in cook chamber; flames from drip tray or below grates during cook.
|
Grease Ignition / Drip Tray Fire | View Details |
| – |
Grease leaking from bottom of grill cabinet instead of into grease bucket.
|
Grease Drainage Failure | View Details |
| – |
Grill overshoots set temperature by 50°F or more and struggles to stabilize, especially at low settings.
|
Temperature Overshoot / Poor Temperature Regulation | View Details |
| – |
Grill powers on but will not ignite; pellets feed into firepot but never light, requiring manual lighting.
|
Weak or Failed Hot Rod Igniter | View Details |
| – |
Grill produces excessive white smoke and sooty residue on food; pellets smolder instead of burning cleanly.
|
Incomplete Combustion / Poor Air-Fuel Mix | View Details |
| – |
Grill starts but then goes out mid-cook; fire dies and temperature drops to ambient while controller continues running.
|
Fire Extinguishing / Flame-Out During Operation | View Details |
| – |
Grill struggles to reach or maintain high temperatures (e.g., cannot exceed 350°F) even with lid closed.
|
Low Maximum Temperature / Insufficient Heat Output | View Details |
| – |
Grilla Grills pellet grill will not power on at all; no lights or display.
|
No Power / Dead Control Board | View Details |
| – |
High-pitched squeal or rattling noise from fan area during cook.
|
Combustion Fan Bearing Wear or Obstruction | View Details |
| – |
Loud grinding or squealing noise from hopper area during operation.
|
Auger Mechanical Noise / Bearing Wear | View Details |
| – |
Meat probe temperature reading is inaccurate or does not change during cook.
|
Faulty Meat Probe or Probe Jack | View Details |
| – |
Paint bubbling or peeling on exterior near firebox or exhaust.
|
High-Heat Paint Failure | View Details |
| – |
Pellets backing up into firepot and overflowing, causing large piles of unburned pellets.
|
Overfeeding / Poor Combustion | View Details |
| – |
Pellets not feeding at all from hopper to firepot, but auger motor can be heard running.
|
Auger Shear Pin Failure or Coupling Slip | View Details |
| – |
Rust forming inside cook chamber or on grates despite normal use.
|
Corrosion of Interior Surfaces | View Details |
| – |
Strong smoke smell or smoke leaking heavily from hopper lid during operation.
|
Backdraft Through Hopper / Poor Exhaust Flow | View Details |
| – |
Water intrusion into hopper or cook chamber after rain, causing pellets to swell and jam.
|
Moisture Ingress / Hopper Water Leak | View Details |
| – |
WiFi or app connectivity issues with Grilla Grills controller (if equipped); cannot connect or maintain connection.
|
Wireless Communication Failure | View Details |