Lochinvar Water Heaters Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E001
Lochinvar condensing gas water heater will not ignite; display shows E001 and burner never lights.
Ignition Failure Lockout
E002
Lochinvar water heater attempts to light but shuts down quickly; display shows E002 and retries ignition several times.
Flame Failure / Loss of Flame Signal
E003
Unit displays E003 and shuts down; blower may run briefly but burner does not light.
Pressure Switch / Air Proving Failure
E004
Lochinvar water heater shows E004 and will not fire; fan may run continuously.
Exhaust / Flue Temperature High or Vent Blocked
E005
Display shows E005 and unit shuts down; may occur during long hot water draws.
Outlet Water Temperature High / Overheat
E006
Unit displays E006 and will not operate; may occur immediately at startup.
Inlet Water Temperature Sensor Fault
E007
Lochinvar heater shows E007; unit may run briefly then shut down.
Outlet Water Temperature Sensor Fault
E008
Control displays E008 and unit locks out; may be accompanied by erratic temperature readings.
Tank Temperature Sensor / Thermistor Fault
E009
Display shows E009; unit may not respond to thermostat or demand signal.
Thermostat / External Control Input Fault
E010
Lochinvar water heater shows E010 and shuts down; may occur during high demand.
High Limit Switch Trip / Manual Reset Limit Open
E011
Display shows E011; unit may not power up fully or may reboot intermittently.
Low Voltage / Power Supply Fault
E012
Lochinvar heater displays E012 and shuts down; fan may continue to run.
Combustion Fan / Blower Fault
E013
Display shows E013; unit may short-cycle or fail to maintain temperature.
Flow Sensor / Flow Switch Fault
E014
Lochinvar water heater shows E014; burner may shut down unexpectedly.
Gas Valve / Gas Train Fault
E015
Display shows E015; unit may not respond to user inputs or may freeze on one screen.
Control Board / EEPROM Fault
E016
Lochinvar heater shows E016; may be associated with condensate leakage or gurgling sounds.
Condensate Drain / Trap Fault
E017
Display shows E017; unit may shut down during operation with no obvious mechanical issue.
Internal Communication Error (Display to Main Board)
E018
Lochinvar water heater shows E018; may be associated with low water pressure or air in system.
Low Water Level / Low System Pressure (Hydronic or Indirect Systems)
E019
Display shows E019; unit may lock out after several failed ignition attempts.
Ignition Lockout (Exceeded Retry Count)
E020
Lochinvar heater shows E020; may be associated with recirculation pump not running.
Pump Output / Recirculation Pump Fault
Symptom
Condensate water dripping from vent joints on a Lochinvar condensing water heater.
Improper Vent Condensate Management
Symptom
Intermittent hot water; Lochinvar heater cycles on and off rapidly, causing temperature swings at fixtures.
Short Cycling / Flow Modulation Issue
Symptom
Lochinvar electric water heater trips the circuit breaker or blows fuses.
Electrical Short / Overcurrent
Symptom
Lochinvar water heater burner is very noisy, with roaring or whistling sound during operation.
Combustion Instability / Improper Gas-Air Mixture
Symptom
Lochinvar water heater cycles off on high limit during long hot water draws, then restarts after cooling.
Inadequate Flow / Overheating Under Load
Symptom
Lochinvar water heater display is blank or unreadable, but unit still heats water.
Display Module Failure
Symptom
Lochinvar water heater does not start; no lights or display, completely dead.
No Power / Control Not Energized
Symptom
Lochinvar water heater fan runs but burner does not light; no error code displayed.
Ignition Sequence Incomplete
Symptom
Lochinvar water heater frequently goes out on pilot (standing pilot models) during windy conditions.
Pilot Flame Instability / Draft Interference
Symptom
Lochinvar water heater makes loud popping or rumbling noises during heating.
Lime Scale Buildup on Heat Exchanger or Tank Bottom
Symptom
Lochinvar water heater produces a rotten egg or sulfur smell in hot water only.
Bacterial Contamination / Anode Reaction
Symptom
Lochinvar water heater shows signs of rust around the anode rod port or hot outlet connection.
Anode Rod Depletion / Localized Corrosion
Symptom
Lochinvar water heater T&P relief valve is dripping or discharging water periodically.
Excessive Temperature or Pressure / T&P Valve Operation
Symptom
No hot water from Lochinvar gas water heater; pilot will not stay lit (standing pilot models).
Thermocouple Failure
Symptom
Water is too hot from Lochinvar water heater, even at low thermostat settings.
Thermostat / Temperature Control Failure
Symptom
Water leaking from the bottom of a Lochinvar tank-type water heater.
Tank Corrosion / Internal Tank Leak
Symptom
Water leaking from the top of a Lochinvar water heater around piping connections.
Top Fitting / Dielectric Nipple Leak
Symptom
Water not hot enough from Lochinvar water heater; runs out of hot water quickly.
Insufficient Heating / Capacity or Control Issue
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E001 |
Lochinvar condensing gas water heater will not ignite; display shows E001 and burner never lights.
|
Ignition Failure Lockout | View Details |
| E002 |
Lochinvar water heater attempts to light but shuts down quickly; display shows E002 and retries ignition several times.
|
Flame Failure / Loss of Flame Signal | View Details |
| E003 |
Unit displays E003 and shuts down; blower may run briefly but burner does not light.
|
Pressure Switch / Air Proving Failure | View Details |
| E004 |
Lochinvar water heater shows E004 and will not fire; fan may run continuously.
|
Exhaust / Flue Temperature High or Vent Blocked | View Details |
| E005 |
Display shows E005 and unit shuts down; may occur during long hot water draws.
|
Outlet Water Temperature High / Overheat | View Details |
| E006 |
Unit displays E006 and will not operate; may occur immediately at startup.
|
Inlet Water Temperature Sensor Fault | View Details |
| E007 |
Lochinvar heater shows E007; unit may run briefly then shut down.
|
Outlet Water Temperature Sensor Fault | View Details |
| E008 |
Control displays E008 and unit locks out; may be accompanied by erratic temperature readings.
|
Tank Temperature Sensor / Thermistor Fault | View Details |
| E009 |
Display shows E009; unit may not respond to thermostat or demand signal.
|
Thermostat / External Control Input Fault | View Details |
| E010 |
Lochinvar water heater shows E010 and shuts down; may occur during high demand.
|
High Limit Switch Trip / Manual Reset Limit Open | View Details |
| E011 |
Display shows E011; unit may not power up fully or may reboot intermittently.
|
Low Voltage / Power Supply Fault | View Details |
| E012 |
Lochinvar heater displays E012 and shuts down; fan may continue to run.
|
Combustion Fan / Blower Fault | View Details |
| E013 |
Display shows E013; unit may short-cycle or fail to maintain temperature.
|
Flow Sensor / Flow Switch Fault | View Details |
| E014 |
Lochinvar water heater shows E014; burner may shut down unexpectedly.
|
Gas Valve / Gas Train Fault | View Details |
| E015 |
Display shows E015; unit may not respond to user inputs or may freeze on one screen.
|
Control Board / EEPROM Fault | View Details |
| E016 |
Lochinvar heater shows E016; may be associated with condensate leakage or gurgling sounds.
|
Condensate Drain / Trap Fault | View Details |
| E017 |
Display shows E017; unit may shut down during operation with no obvious mechanical issue.
|
Internal Communication Error (Display to Main Board) | View Details |
| E018 |
Lochinvar water heater shows E018; may be associated with low water pressure or air in system.
|
Low Water Level / Low System Pressure (Hydronic or Indirect Systems) | View Details |
| E019 |
Display shows E019; unit may lock out after several failed ignition attempts.
|
Ignition Lockout (Exceeded Retry Count) | View Details |
| E020 |
Lochinvar heater shows E020; may be associated with recirculation pump not running.
|
Pump Output / Recirculation Pump Fault | View Details |
| – |
Condensate water dripping from vent joints on a Lochinvar condensing water heater.
|
Improper Vent Condensate Management | View Details |
| – |
Intermittent hot water; Lochinvar heater cycles on and off rapidly, causing temperature swings at fixtures.
|
Short Cycling / Flow Modulation Issue | View Details |
| – |
Lochinvar electric water heater trips the circuit breaker or blows fuses.
|
Electrical Short / Overcurrent | View Details |
| – |
Lochinvar water heater burner is very noisy, with roaring or whistling sound during operation.
|
Combustion Instability / Improper Gas-Air Mixture | View Details |
| – |
Lochinvar water heater cycles off on high limit during long hot water draws, then restarts after cooling.
|
Inadequate Flow / Overheating Under Load | View Details |
| – |
Lochinvar water heater display is blank or unreadable, but unit still heats water.
|
Display Module Failure | View Details |
| – |
Lochinvar water heater does not start; no lights or display, completely dead.
|
No Power / Control Not Energized | View Details |
| – |
Lochinvar water heater fan runs but burner does not light; no error code displayed.
|
Ignition Sequence Incomplete | View Details |
| – |
Lochinvar water heater frequently goes out on pilot (standing pilot models) during windy conditions.
|
Pilot Flame Instability / Draft Interference | View Details |
| – |
Lochinvar water heater makes loud popping or rumbling noises during heating.
|
Lime Scale Buildup on Heat Exchanger or Tank Bottom | View Details |
| – |
Lochinvar water heater produces a rotten egg or sulfur smell in hot water only.
|
Bacterial Contamination / Anode Reaction | View Details |
| – |
Lochinvar water heater shows signs of rust around the anode rod port or hot outlet connection.
|
Anode Rod Depletion / Localized Corrosion | View Details |
| – |
Lochinvar water heater T&P relief valve is dripping or discharging water periodically.
|
Excessive Temperature or Pressure / T&P Valve Operation | View Details |
| – |
No hot water from Lochinvar gas water heater; pilot will not stay lit (standing pilot models).
|
Thermocouple Failure | View Details |
| – |
Water is too hot from Lochinvar water heater, even at low thermostat settings.
|
Thermostat / Temperature Control Failure | View Details |
| – |
Water leaking from the bottom of a Lochinvar tank-type water heater.
|
Tank Corrosion / Internal Tank Leak | View Details |
| – |
Water leaking from the top of a Lochinvar water heater around piping connections.
|
Top Fitting / Dielectric Nipple Leak | View Details |
| – |
Water not hot enough from Lochinvar water heater; runs out of hot water quickly.
|
Insufficient Heating / Capacity or Control Issue | View Details |