E1
Control panel displays E1 and the softener does not start a regeneration cycle
Inlet Water Supply Fault
E10
E10 error and the unit cannot detect the resin tank position
Piston / Position Sensor Fault
E11
E11 error and the brine draw stage does not start or stops prematurely
Brine Draw Vacuum Fault
E12
E12 error and the unit overfills the brine tank with water
Brine Refill Control Fault
E13
E13 error and the unit reports excessive water usage or regenerates too frequently
Flow Meter Over‑Range / Leak Detection Fault
E14
E14 error and the unit cannot detect salt level (on models with electronic salt sensor)
Salt Level Sensor Fault
E15
E15 error and the unit reports low salt even when the tank is full (on models with salt sensor)
Salt Level Calibration / Reading Error
E16
E16 error and the unit indicates drain flow problems during regeneration
Drain Line Flow Fault
E17
E17 error and the unit cannot detect the home position after power‑up
Home Position / Reference Switch Fault
E18
E18 error and the unit reports abnormal conductivity or hardness after regeneration (on models with sensor)
Water Quality Sensor Fault
E19
E19 error and the unit indicates simultaneous conflicting valve positions
Valve Position Logic / Sensor Conflict
E2
Display shows E2 and the unit stops mid‑regeneration
Brine Tank Low Water / Brine Fill Fault
E20
E20 error and the unit reports internal memory checksum failure
Firmware / Memory Integrity Fault
E3
E3 error and the softener remains in service mode without regenerating on schedule
Flow Meter / Turbine Sensor Failure
E4
E4 displayed and the control valve is stuck in one position during regeneration
Motor / Cam Position Fault
E5
E5 error and the display is frozen or unresponsive
Control Board Communication / EEPROM Fault
E6
E6 displayed and the time or usage data resets randomly
Real‑Time Clock / Backup Power Fault
E7
E7 error and the display shows abnormal temperature or shuts down in hot environments
Control Head Over‑Temperature / Temperature Sensor Fault
E8
E8 error and the unit skips or aborts regeneration cycles
Regeneration Program / Parameter Error
E9
E9 error and the display shows no flow even when taps are open
Usage Meter Calibration / Signal Error
Symptom
Brine tank fills with water and overflows periodically
Brine Tank Overfill
Symptom
Brine tank has water but salt level does not drop over time
Salt Bridge / Salt Mushing
Symptom
Nobel softener will not start at all, display is blank and unit is unresponsive
No Power / Dead Control
Symptom
Softener causes noticeable drop in water pressure throughout the house
Flow Restriction Through Softener
Symptom
Softener causes salty taste in household water after regeneration
Excessive Brine Carryover
Symptom
Softener continuously drains water even when not in regeneration (slow trickle to drain)
Internal Valve Leak to Drain
Symptom
Softener display works but buttons do not respond or respond intermittently
Keypad / User Interface Fault
Symptom
Softener does not regenerate at night as scheduled (no error code, clock appears correct)
Regeneration Scheduling / Trigger Fault
Symptom
Softener draws no brine during regeneration; brine level in tank does not drop
No Brine Draw
Symptom
Softener emits a strong rotten‑egg or musty odor from the brine tank
Bacterial Growth in Brine Tank
Symptom
Softener installed but water remains hard because unit is plumbed incorrectly
Incorrect Plumbing / Bypass Piping
Symptom
Softener installed in cold area experiences intermittent operation or leaks during freezing weather
Freeze Damage / Seasonal Fault
Symptom
Softener is leaking water from around the control head
Control Valve External Leak
Symptom
Softener makes loud clicking, grinding, or knocking noises during regeneration
Mechanical Noise from Control Valve
Symptom
Softener never regenerates, even after long periods of water use
Under‑Regeneration / No Trigger
Symptom
Softener regenerates too frequently, wasting salt and water
Over‑Regeneration
Symptom
Softener stuck in regeneration and continuously running water to drain
Control Valve Stuck in Backwash/Rinse
Symptom
Visible resin beads appear in household faucets and aerators
Resin Loss into Plumbing
Symptom
Water leaking from the base of the resin tank
Resin Tank Structural Leak
Symptom
Water remains hard at taps even though the Nobel softener appears to run normally (no error code)
Loss of Softening Capacity
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E1 |
Control panel displays E1 and the softener does not start a regeneration cycle
|
Inlet Water Supply Fault | View Details |
| E10 |
E10 error and the unit cannot detect the resin tank position
|
Piston / Position Sensor Fault | View Details |
| E11 |
E11 error and the brine draw stage does not start or stops prematurely
|
Brine Draw Vacuum Fault | View Details |
| E12 |
E12 error and the unit overfills the brine tank with water
|
Brine Refill Control Fault | View Details |
| E13 |
E13 error and the unit reports excessive water usage or regenerates too frequently
|
Flow Meter Over‑Range / Leak Detection Fault | View Details |
| E14 |
E14 error and the unit cannot detect salt level (on models with electronic salt sensor)
|
Salt Level Sensor Fault | View Details |
| E15 |
E15 error and the unit reports low salt even when the tank is full (on models with salt sensor)
|
Salt Level Calibration / Reading Error | View Details |
| E16 |
E16 error and the unit indicates drain flow problems during regeneration
|
Drain Line Flow Fault | View Details |
| E17 |
E17 error and the unit cannot detect the home position after power‑up
|
Home Position / Reference Switch Fault | View Details |
| E18 |
E18 error and the unit reports abnormal conductivity or hardness after regeneration (on models with sensor)
|
Water Quality Sensor Fault | View Details |
| E19 |
E19 error and the unit indicates simultaneous conflicting valve positions
|
Valve Position Logic / Sensor Conflict | View Details |
| E2 |
Display shows E2 and the unit stops mid‑regeneration
|
Brine Tank Low Water / Brine Fill Fault | View Details |
| E20 |
E20 error and the unit reports internal memory checksum failure
|
Firmware / Memory Integrity Fault | View Details |
| E3 |
E3 error and the softener remains in service mode without regenerating on schedule
|
Flow Meter / Turbine Sensor Failure | View Details |
| E4 |
E4 displayed and the control valve is stuck in one position during regeneration
|
Motor / Cam Position Fault | View Details |
| E5 |
E5 error and the display is frozen or unresponsive
|
Control Board Communication / EEPROM Fault | View Details |
| E6 |
E6 displayed and the time or usage data resets randomly
|
Real‑Time Clock / Backup Power Fault | View Details |
| E7 |
E7 error and the display shows abnormal temperature or shuts down in hot environments
|
Control Head Over‑Temperature / Temperature Sensor Fault | View Details |
| E8 |
E8 error and the unit skips or aborts regeneration cycles
|
Regeneration Program / Parameter Error | View Details |
| E9 |
E9 error and the display shows no flow even when taps are open
|
Usage Meter Calibration / Signal Error | View Details |
| – |
Brine tank fills with water and overflows periodically
|
Brine Tank Overfill | View Details |
| – |
Brine tank has water but salt level does not drop over time
|
Salt Bridge / Salt Mushing | View Details |
| – |
Nobel softener will not start at all, display is blank and unit is unresponsive
|
No Power / Dead Control | View Details |
| – |
Softener causes noticeable drop in water pressure throughout the house
|
Flow Restriction Through Softener | View Details |
| – |
Softener causes salty taste in household water after regeneration
|
Excessive Brine Carryover | View Details |
| – |
Softener continuously drains water even when not in regeneration (slow trickle to drain)
|
Internal Valve Leak to Drain | View Details |
| – |
Softener display works but buttons do not respond or respond intermittently
|
Keypad / User Interface Fault | View Details |
| – |
Softener does not regenerate at night as scheduled (no error code, clock appears correct)
|
Regeneration Scheduling / Trigger Fault | View Details |
| – |
Softener draws no brine during regeneration; brine level in tank does not drop
|
No Brine Draw | View Details |
| – |
Softener emits a strong rotten‑egg or musty odor from the brine tank
|
Bacterial Growth in Brine Tank | View Details |
| – |
Softener installed but water remains hard because unit is plumbed incorrectly
|
Incorrect Plumbing / Bypass Piping | View Details |
| – |
Softener installed in cold area experiences intermittent operation or leaks during freezing weather
|
Freeze Damage / Seasonal Fault | View Details |
| – |
Softener is leaking water from around the control head
|
Control Valve External Leak | View Details |
| – |
Softener makes loud clicking, grinding, or knocking noises during regeneration
|
Mechanical Noise from Control Valve | View Details |
| – |
Softener never regenerates, even after long periods of water use
|
Under‑Regeneration / No Trigger | View Details |
| – |
Softener regenerates too frequently, wasting salt and water
|
Over‑Regeneration | View Details |
| – |
Softener stuck in regeneration and continuously running water to drain
|
Control Valve Stuck in Backwash/Rinse | View Details |
| – |
Visible resin beads appear in household faucets and aerators
|
Resin Loss into Plumbing | View Details |
| – |
Water leaking from the base of the resin tank
|
Resin Tank Structural Leak | View Details |
| – |
Water remains hard at taps even though the Nobel softener appears to run normally (no error code)
|
Loss of Softening Capacity | View Details |