E1
Dehumidifier will not start and displays E1 on the control panel
Room Temperature Sensor Failure
E2
Dehumidifier stops and shows E2 on the display, fan may still run briefly
Evaporator Coil Temperature Sensor Failure
E3
Dehumidifier displays E3 and will not start dehumidification
Humidity Sensor (RH Sensor) Failure
E4
Dehumidifier shows E4 and stops cooling, fan may run intermittently
Defrost Sensor or Anti-Frost Protection Fault
E5
Dehumidifier beeps and shows E5, compressor does not start
Compressor Overload or High-Pressure Protection Fault
E6
Dehumidifier shows E6 and stops, fan may still operate
Fan Motor or Fan Feedback Fault
E7
Dehumidifier displays E7 and does not dehumidify
Water Level Sensor or Float Switch Fault
E8
Dehumidifier shows E8 and shuts down shortly after starting
Low Refrigerant or Refrigeration System Protection Fault
E9
Dehumidifier displays E9 and will not run the compressor
EEPROM or Control Board Memory Error
EC
Dehumidifier shows EC and stops dehumidifying
Refrigerant System Error / Sensor Calibration Error
F1
Humidifier shows F1 and stops producing mist
Water Level Sensor Fault (Humidifier Reservoir)
F2
Humidifier displays F2 and mist output stops
Ultrasonic Transducer Overheat or Dry-Run Protection
F3
Humidifier shows F3 and controls may be unresponsive
Humidity Sensor Fault (Humidifier)
F4
Humidifier displays F4 and shuts down unexpectedly
Overheat Protection or Temperature Sensor Fault
HI
Dehumidifier display shows HI and runs continuously
High Humidity Indication / Sensor Out of Range
LO
Dehumidifier display shows LO and compressor does not run
Low Temperature Lockout
P1
Dehumidifier shows P1 and does not start dehumidifying
Defrost Mode Active / Low Temperature Protection
P2
Dehumidifier shows P2 and stops, water tank is full
Water Tank Full Indication
Symptom
Dehumidifier display and buttons do not respond, but unit is powered
Unresponsive Control Panel / Keypad Failure
Symptom
Dehumidifier emits a burning smell or hot plastic odor
Overheating Component / Electrical Fault
Symptom
Dehumidifier fan runs but compressor cycles on and off rapidly
Short Cycling / Compressor Control Fault
Symptom
Dehumidifier ice buildup on evaporator fins and reduced airflow
Evaporator Icing / Defrost Failure
Symptom
Dehumidifier makes loud rattling or grinding noise during operation
Mechanical Noise / Fan or Compressor Mounting Fault
Symptom
Dehumidifier powers on but fan does not run, compressor may start briefly then stop
Fan Not Running / Airflow Failure
Symptom
Dehumidifier runs but does not collect water in the tank
No Dehumidification / Poor Moisture Removal
Symptom
Dehumidifier runs continuously and never reaches the set humidity
Inaccurate Humidity Control / Sensor or Sizing Issue
Symptom
Dehumidifier stops frequently with water tank not full
False Tank Full Detection
Symptom
Dehumidifier vibrates excessively and moves on the floor
Excessive Vibration / Imbalanced Fan or Loose Mounts
Symptom
Dehumidifier will not power on at all (no lights, no display)
No Power / Power Supply Failure
Symptom
Humidifier creates white dust on nearby surfaces
Mineral Dust Emission
Symptom
Humidifier display works but buttons do not change settings
Keypad / Touch Sensor Failure
Symptom
Humidifier emits unpleasant or musty odor during operation
Odor / Microbial Growth in Water System
Symptom
Humidifier leaks water around the base or onto furniture
Water Leak / Tank or Seal Failure
Symptom
Humidifier produces weak mist even at maximum setting
Reduced Mist Output / Flow Restriction
Symptom
Humidifier runs but no visible mist is produced
No Mist Output / Ultrasonic Failure
Symptom
Humidifier shuts off after a few minutes even with water in the tank
Premature Shutoff / Level or Overheat Protection
Symptom
Water leaking from the bottom of the dehumidifier onto the floor
Water Leak / Drainage System Fault
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E1 |
Dehumidifier will not start and displays E1 on the control panel
|
Room Temperature Sensor Failure | View Details |
| E2 |
Dehumidifier stops and shows E2 on the display, fan may still run briefly
|
Evaporator Coil Temperature Sensor Failure | View Details |
| E3 |
Dehumidifier displays E3 and will not start dehumidification
|
Humidity Sensor (RH Sensor) Failure | View Details |
| E4 |
Dehumidifier shows E4 and stops cooling, fan may run intermittently
|
Defrost Sensor or Anti-Frost Protection Fault | View Details |
| E5 |
Dehumidifier beeps and shows E5, compressor does not start
|
Compressor Overload or High-Pressure Protection Fault | View Details |
| E6 |
Dehumidifier shows E6 and stops, fan may still operate
|
Fan Motor or Fan Feedback Fault | View Details |
| E7 |
Dehumidifier displays E7 and does not dehumidify
|
Water Level Sensor or Float Switch Fault | View Details |
| E8 |
Dehumidifier shows E8 and shuts down shortly after starting
|
Low Refrigerant or Refrigeration System Protection Fault | View Details |
| E9 |
Dehumidifier displays E9 and will not run the compressor
|
EEPROM or Control Board Memory Error | View Details |
| EC |
Dehumidifier shows EC and stops dehumidifying
|
Refrigerant System Error / Sensor Calibration Error | View Details |
| F1 |
Humidifier shows F1 and stops producing mist
|
Water Level Sensor Fault (Humidifier Reservoir) | View Details |
| F2 |
Humidifier displays F2 and mist output stops
|
Ultrasonic Transducer Overheat or Dry-Run Protection | View Details |
| F3 |
Humidifier shows F3 and controls may be unresponsive
|
Humidity Sensor Fault (Humidifier) | View Details |
| F4 |
Humidifier displays F4 and shuts down unexpectedly
|
Overheat Protection or Temperature Sensor Fault | View Details |
| HI |
Dehumidifier display shows HI and runs continuously
|
High Humidity Indication / Sensor Out of Range | View Details |
| LO |
Dehumidifier display shows LO and compressor does not run
|
Low Temperature Lockout | View Details |
| P1 |
Dehumidifier shows P1 and does not start dehumidifying
|
Defrost Mode Active / Low Temperature Protection | View Details |
| P2 |
Dehumidifier shows P2 and stops, water tank is full
|
Water Tank Full Indication | View Details |
| – |
Dehumidifier display and buttons do not respond, but unit is powered
|
Unresponsive Control Panel / Keypad Failure | View Details |
| – |
Dehumidifier emits a burning smell or hot plastic odor
|
Overheating Component / Electrical Fault | View Details |
| – |
Dehumidifier fan runs but compressor cycles on and off rapidly
|
Short Cycling / Compressor Control Fault | View Details |
| – |
Dehumidifier ice buildup on evaporator fins and reduced airflow
|
Evaporator Icing / Defrost Failure | View Details |
| – |
Dehumidifier makes loud rattling or grinding noise during operation
|
Mechanical Noise / Fan or Compressor Mounting Fault | View Details |
| – |
Dehumidifier powers on but fan does not run, compressor may start briefly then stop
|
Fan Not Running / Airflow Failure | View Details |
| – |
Dehumidifier runs but does not collect water in the tank
|
No Dehumidification / Poor Moisture Removal | View Details |
| – |
Dehumidifier runs continuously and never reaches the set humidity
|
Inaccurate Humidity Control / Sensor or Sizing Issue | View Details |
| – |
Dehumidifier stops frequently with water tank not full
|
False Tank Full Detection | View Details |
| – |
Dehumidifier vibrates excessively and moves on the floor
|
Excessive Vibration / Imbalanced Fan or Loose Mounts | View Details |
| – |
Dehumidifier will not power on at all (no lights, no display)
|
No Power / Power Supply Failure | View Details |
| – |
Humidifier creates white dust on nearby surfaces
|
Mineral Dust Emission | View Details |
| – |
Humidifier display works but buttons do not change settings
|
Keypad / Touch Sensor Failure | View Details |
| – |
Humidifier emits unpleasant or musty odor during operation
|
Odor / Microbial Growth in Water System | View Details |
| – |
Humidifier leaks water around the base or onto furniture
|
Water Leak / Tank or Seal Failure | View Details |
| – |
Humidifier produces weak mist even at maximum setting
|
Reduced Mist Output / Flow Restriction | View Details |
| – |
Humidifier runs but no visible mist is produced
|
No Mist Output / Ultrasonic Failure | View Details |
| – |
Humidifier shuts off after a few minutes even with water in the tank
|
Premature Shutoff / Level or Overheat Protection | View Details |
| – |
Water leaking from the bottom of the dehumidifier onto the floor
|
Water Leak / Drainage System Fault | View Details |
No matching codes found