Northair

Northair Ice Makers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E1
Northair ice maker will not power on, display shows E1 shortly after plugging in, no fans or compressor start.
Main Temperature Sensor (Cabinet Thermistor) Failure
E10
Display shows E10; ice bin is empty but the unit will not start a new cycle and behaves as if the bin is full.
Ice Bin Full Sensor / Infrared Beam Fault
E11
Northair ice maker shows E11; control panel is responsive but no ice-making functions start.
Keypad / User Interface Communication Fault
E12
Display shows E12; unit may intermittently shut off or restart during operation.
Power Supply / Voltage Fault
E2
Display shows E2 and the unit stops making ice; fan may run but compressor cycles off quickly.
Evaporator Temperature Sensor Failure
E3
Northair ice maker beeps and shows E3; ice cycle stops mid-way and ice may be too thick or too thin.
Ice Thickness Sensor / Probe Fault
E4
Display shows E4 and the unit stops; ice harvest may not complete and ice may stick to the evaporator.
Defrost / Harvest Sensor or Hot Gas Valve Control Fault
E5
Northair ice maker shows E5 and stops making ice; water may fill but no freezing occurs or cycle aborts early.
Compressor Overload / High Temperature Protection Fault
E6
Display shows E6; unit may power on but will not start an ice-making cycle.
Water Level Sensor / Float Switch Fault
E7
Northair ice maker shows E7; water pump may not run and no water circulates over the evaporator.
Water Circulation Pump Failure
E8
Display shows E8; unit may fill with water but then drains immediately or will not hold water in the reservoir.
Drain Pump or Drain Valve Fault
E9
Northair ice maker shows E9; unit may run briefly then shut down, sometimes with beeping, and no ice is produced.
Low Refrigerant / Refrigeration System Performance Fault (Sensor-Detected)
Symptom
Control panel buttons are unresponsive or only some buttons work intermittently.
Keypad / Touch Control Failure
Symptom
Display is dim, flickering, or segments are missing, but the unit still makes ice.
Display Module Degradation
Symptom
Display is on and buttons respond, but the ice maker will not start a cycle when Start is pressed.
Control Logic Lockout / Safety Interlock Not Satisfied
Symptom
Evaporator plate ices up excessively with thick frost, and ice harvest becomes unreliable.
Evaporator Overfrost / Defrost-Harvest Imbalance
Symptom
Ice appears cloudy or white instead of clear.
Entrained Air and Mineral Content in Ice
Symptom
Ice has a bad taste or odor, even when freshly made.
Contaminated Water Path / Biofilm or Odor Absorption
Symptom
Ice maker cycles on and off frequently and cannot maintain consistent ice production.
Short Cycling / Overheating or Sensor Misread
Symptom
Ice maker does not fill with water; pump runs dry and no water reaches the evaporator.
No Water Fill
Symptom
Ice maker fills with water but then immediately drains it without making ice.
Improper Drainage / Siphoning
Symptom
Ice maker is making ice, but there is a loud grinding or rattling noise during operation.
Mechanical Noise from Fan, Pump, or Loose Components
Symptom
Ice maker overfills with water, causing water to spill into the bin or out of the unit.
Overfill / Water Level Control Failure
Symptom
Ice maker produces ice, but cubes are very small, hollow, or melt quickly in the bin.
Insufficient Freeze Capacity / Poor Heat Transfer
Symptom
Ice maker runs continuously and does not stop making ice even when the bin is full.
Bin Full Detection Failure
Symptom
Ice maker will not start at all; no lights on the display and no response to buttons.
No Power / Dead Unit
Symptom
Ice production is much slower than specified, even though the unit eventually fills the bin.
Reduced Ice Production Rate
Symptom
Ice sticks together in large clumps in the bin and does not dispense easily.
Ice Clumping / Poor Bin Drainage or Warm Air Infiltration
Symptom
Northair ice maker is leaking water onto the countertop or floor during or after operation.
External or Internal Water Leak
Symptom
Northair ice maker runs but makes no ice at all; fan and compressor may run, but the evaporator plate does not get cold.
Compressor or Sealed System Failure
Symptom
Northair ice maker vibrates excessively or walks on the counter during operation.
Excessive Vibration / Poor Leveling
Symptom
Unit displays lights but the compressor never starts; only the fan and pump run.
Compressor Start Circuit Failure
Symptom
Unit emits a burning smell or visible smoke during operation.
Overheating Electrical Component
Symptom
Unit runs but interior cabinet or bin feels unusually warm, and ice melts very quickly.
Cabinet Insulation or Fan Airflow Issue
Symptom
Unit trips the household breaker or GFCI outlet when it starts.
Electrical Short or Ground Fault
Symptom
Water remains in the bin or cabinet area and does not drain properly after ice melts.
Poor Drainage / Standing Water
Advertisements