Calpeda
Calpeda Pool Pumps Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E01
Pump will not start, digital controller shows E01 immediately after power-on
Motor Overload / Overcurrent Protection Trip
E02
Pump stops during operation and controller displays E02, will restart after cooling
Thermal Overload / Motor Overheating
E03
Controller shows E03 and pump does not start, sometimes after a power outage
Phase Loss / Phase Imbalance (Three-Phase Models)
E04
Digital controller displays E04 and pump stops shortly after starting
Dry-Run Protection / Low Flow Detected
E05
Controller shows E05 and pump will not start, often after wiring changes
Motor Wiring / Connection Error
E06
Pump starts then stops with E06, sometimes accompanied by humming noise
Capacitor Failure (Single-Phase Models)
E07
Controller displays E07 and pump speed cannot be adjusted on variable-speed Calpeda pool pump
Inverter / VFD Overvoltage or DC Bus Fault
E08
Pump controller shows E08 and motor runs very slowly or not at all
Undervoltage / Low Supply Voltage
E09
Controller displays E09 and pump stops abruptly during operation
Earth Leakage / Ground Fault Detected
E10
Variable-speed Calpeda pump shows E10 and cannot reach set RPM
Overload / Torque Limit Exceeded
E11
Controller shows E11 and pump runs but display indicates sensor error
Temperature Sensor Fault (Motor or Water)
E12
Display shows E12 and pump cannot be controlled from external automation
Communication Error (Modbus / External Control)
E13
Controller intermittently shows E13 and pump stops randomly
Internal Controller Fault / Memory Error
E14
Display shows E14 and pump cannot start due to locked keypad
Keypad Lock / User Interface Lockout
E15
Controller shows E15 and pump stops when external safety input is triggered
External Interlock / Safety Chain Open
Symptom
Pump cannot be primed; it loses water from the housing when turned off
Non-Return / Check Valve Failure or Housing Leak
Symptom
Pump cannot be turned off from the local keypad but stops when breaker is opened
Stuck Contactor / Control Relay Fault
Symptom
Pump display is blank but motor runs when external command is present
Display / HMI Failure
Symptom
Pump emits a burning smell or visible smoke from motor area
Motor Overheating / Insulation Breakdown
Symptom
Pump housing or surrounding area is leaking water while pump is running
Mechanical Seal or Housing Leak
Symptom
Pump is very noisy with a grinding or screeching sound while running
Worn Motor Bearings
Symptom
Pump lid is difficult to remove and there is strong vacuum when opening
Excessive Suction / Blocked Return
Symptom
Pump makes a loud rattling or clattering noise, especially at startup
Cavitation / Impeller Damage
Symptom
Pump motor is very hot to the touch but still running
Overheating Under Load
Symptom
Pump runs but air bubbles are visible in the pump lid and at pool returns
Suction Air Leak
Symptom
Pump runs but flow is weak and jets in the pool are barely moving
Restricted Flow / System Head Too High
Symptom
Pump runs but there is a high-pitched whine from the motor, especially on variable-speed models
Inverter Switching Noise / Bearing Resonance
Symptom
Pump runs but there is no water flow to the pool
Loss of Prime / Airlocked Pump
Symptom
Pump runs but water appears cloudy and circulation seems poor despite normal pressure
Insufficient Turnover / Incorrect Speed Setting
Symptom
Pump runs normally but there is water dripping from the motor end shield
Advanced Mechanical Seal Failure with Motor Contamination
Symptom
Pump speed fluctuates up and down without user input on variable-speed model
Unstable Control Signal / Sensor Feedback Issue
Symptom
Pump starts and stops repeatedly every few seconds
Short Cycling / Control Instability
Symptom
Pump trips the circuit breaker immediately when switched on
Short Circuit / Locked Rotor
Symptom
Pump vibrates excessively and moves on its base during operation
Imbalance / Misalignment
Symptom
Pump will not restart automatically after a power outage
Auto-Restart Disabled / Control Logic Issue
Symptom
Pump will not start, only a humming sound is heard for a few seconds
Failed Start Circuit (Single-Phase)
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E01 |
Pump will not start, digital controller shows E01 immediately after power-on
|
Motor Overload / Overcurrent Protection Trip | View Details |
| E02 |
Pump stops during operation and controller displays E02, will restart after cooling
|
Thermal Overload / Motor Overheating | View Details |
| E03 |
Controller shows E03 and pump does not start, sometimes after a power outage
|
Phase Loss / Phase Imbalance (Three-Phase Models) | View Details |
| E04 |
Digital controller displays E04 and pump stops shortly after starting
|
Dry-Run Protection / Low Flow Detected | View Details |
| E05 |
Controller shows E05 and pump will not start, often after wiring changes
|
Motor Wiring / Connection Error | View Details |
| E06 |
Pump starts then stops with E06, sometimes accompanied by humming noise
|
Capacitor Failure (Single-Phase Models) | View Details |
| E07 |
Controller displays E07 and pump speed cannot be adjusted on variable-speed Calpeda pool pump
|
Inverter / VFD Overvoltage or DC Bus Fault | View Details |
| E08 |
Pump controller shows E08 and motor runs very slowly or not at all
|
Undervoltage / Low Supply Voltage | View Details |
| E09 |
Controller displays E09 and pump stops abruptly during operation
|
Earth Leakage / Ground Fault Detected | View Details |
| E10 |
Variable-speed Calpeda pump shows E10 and cannot reach set RPM
|
Overload / Torque Limit Exceeded | View Details |
| E11 |
Controller shows E11 and pump runs but display indicates sensor error
|
Temperature Sensor Fault (Motor or Water) | View Details |
| E12 |
Display shows E12 and pump cannot be controlled from external automation
|
Communication Error (Modbus / External Control) | View Details |
| E13 |
Controller intermittently shows E13 and pump stops randomly
|
Internal Controller Fault / Memory Error | View Details |
| E14 |
Display shows E14 and pump cannot start due to locked keypad
|
Keypad Lock / User Interface Lockout | View Details |
| E15 |
Controller shows E15 and pump stops when external safety input is triggered
|
External Interlock / Safety Chain Open | View Details |
| – |
Pump cannot be primed; it loses water from the housing when turned off
|
Non-Return / Check Valve Failure or Housing Leak | View Details |
| – |
Pump cannot be turned off from the local keypad but stops when breaker is opened
|
Stuck Contactor / Control Relay Fault | View Details |
| – |
Pump display is blank but motor runs when external command is present
|
Display / HMI Failure | View Details |
| – |
Pump emits a burning smell or visible smoke from motor area
|
Motor Overheating / Insulation Breakdown | View Details |
| – |
Pump housing or surrounding area is leaking water while pump is running
|
Mechanical Seal or Housing Leak | View Details |
| – |
Pump is very noisy with a grinding or screeching sound while running
|
Worn Motor Bearings | View Details |
| – |
Pump lid is difficult to remove and there is strong vacuum when opening
|
Excessive Suction / Blocked Return | View Details |
| – |
Pump makes a loud rattling or clattering noise, especially at startup
|
Cavitation / Impeller Damage | View Details |
| – |
Pump motor is very hot to the touch but still running
|
Overheating Under Load | View Details |
| – |
Pump runs but air bubbles are visible in the pump lid and at pool returns
|
Suction Air Leak | View Details |
| – |
Pump runs but flow is weak and jets in the pool are barely moving
|
Restricted Flow / System Head Too High | View Details |
| – |
Pump runs but there is a high-pitched whine from the motor, especially on variable-speed models
|
Inverter Switching Noise / Bearing Resonance | View Details |
| – |
Pump runs but there is no water flow to the pool
|
Loss of Prime / Airlocked Pump | View Details |
| – |
Pump runs but water appears cloudy and circulation seems poor despite normal pressure
|
Insufficient Turnover / Incorrect Speed Setting | View Details |
| – |
Pump runs normally but there is water dripping from the motor end shield
|
Advanced Mechanical Seal Failure with Motor Contamination | View Details |
| – |
Pump speed fluctuates up and down without user input on variable-speed model
|
Unstable Control Signal / Sensor Feedback Issue | View Details |
| – |
Pump starts and stops repeatedly every few seconds
|
Short Cycling / Control Instability | View Details |
| – |
Pump trips the circuit breaker immediately when switched on
|
Short Circuit / Locked Rotor | View Details |
| – |
Pump vibrates excessively and moves on its base during operation
|
Imbalance / Misalignment | View Details |
| – |
Pump will not restart automatically after a power outage
|
Auto-Restart Disabled / Control Logic Issue | View Details |
| – |
Pump will not start, only a humming sound is heard for a few seconds
|
Failed Start Circuit (Single-Phase) | View Details |
No matching codes found