Kohler Standby Generators Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
Air Filter Restriction
Controller displays “Air Filter” or “Restricted Air Filter”; engine may run rich or lack power.
Intake Air Restriction Detected
Charger Failure
Controller displays “Battery Charger Failure” or similar alarm; battery voltage slowly drops over days.
Battery Charger Output Failure
Emergency Stop
Controller displays “Emergency Stop” or “E-Stop Active”; generator will not start.
Emergency Stop Circuit Activated
Ground Fault
Controller displays “Ground Fault” or “Earth Fault”; generator may trip off-line.
Ground Fault Detection Trip
High Battery Voltage
Controller displays “High Battery Voltage” or “Battery Overvoltage”; battery may feel warm or venting.
Battery Overcharging Condition
High Coolant Temperature
Controller displays “High Coolant Temp” on liquid-cooled models; generator shuts down under load.
Coolant Overtemperature Shutdown
High Engine Temperature
Controller displays “High Engine Temp” or “Overtemperature”; generator shuts down during operation.
Engine Overheat Shutdown
Loss of Phase
On three-phase Kohler standby generators, controller displays “Loss of Phase” or “Phase Failure”; some loads lose power.
Missing or Low Voltage on One or More Phases
Loss of Sensing
Controller displays “Loss of Sensing” or “Voltage Sense Loss”; generator may run but not transfer load.
Controller Voltage Sensing Circuit Failure
Low Battery Voltage
Controller displays “Low Battery Voltage” or “Low Battery”; generator may fail to crank or cranks slowly.
Starting Battery Under-Voltage Condition
Low Coolant Level
Liquid-cooled Kohler standby generator shuts down and displays “Low Coolant Level” or coolant level alarm.
Engine Coolant Level Protection Trip
Low Coolant Temperature
Controller displays “Low Coolant Temp” on liquid-cooled models; may inhibit automatic transfer under load.
Coolant Temperature Below Minimum for Load Acceptance
Low Cranking Speed
Controller displays “Low Cranking Speed” or similar; engine turns slowly and fails to start.
Starter Cranking RPM Below Threshold
Low Engine Temperature
Controller displays “Low Engine Temp” or “Engine Not Warmed Up”; unit may not transfer load or may run longer in exercise mode.
Engine Coolant Temperature Below Minimum Threshold
Low Fuel Pressure
Controller displays “Low Fuel Pressure” or “Fuel Pressure” alarm; engine may stall or fail to start.
Gaseous Fuel Supply Pressure Fault
Low Oil Level
Some Kohler models display “Low Oil Level” separate from pressure; generator may not start or may shut down.
Engine Oil Level Sensor Trip
Low Oil Pressure
Generator shuts down shortly after start and controller displays “Low Oil Pressure” fault.
Engine Low Oil Pressure Shutdown
Overcrank
Controller displays “Overcrank” after multiple failed start attempts; engine cranks but does not start.
Failed Engine Start / Overcrank Lockout
Overfrequency
Controller displays “Overfrequency” and may shut down or drop load; measured frequency is above 63 Hz on a 60 Hz unit.
Engine Overspeed / High Frequency Condition
Overload
Controller displays “Overload” or “Overcurrent”; main breaker trips when large loads start on generator power.
Generator Overcurrent / Overload Trip
Overspeed
Controller displays “Overspeed” and shuts the engine down quickly after start; may be accompanied by high frequency readings.
Engine Overspeed Protection Trip
Overvoltage
Controller displays “Overvoltage” and opens the main line circuit breaker; generator stops supplying power.
Generator Output Overvoltage Protection Trip
Service Required
Controller displays “Service Required” or “Maintenance Reminder”; generator still operates normally.
Scheduled Maintenance Interval Reached
Service Soon
Controller displays “Service Soon” or similar pre-maintenance warning; generator operates normally.
Upcoming Maintenance Interval Warning
Underfrequency
Controller displays “Underfrequency” or “Low Frequency”; lights flicker and motors sound sluggish when on generator power.
Engine Underspeed / Low Frequency Condition
Underspeed
Controller displays “Underspeed” shortly after start; engine may stall or run roughly at low RPM.
Engine Speed Below Minimum Threshold
Undervoltage
Controller displays “Undervoltage” or “Low Voltage” and drops the load; lights dim or equipment resets when generator runs.
Generator Output Undervoltage Condition
Symptom
Controller display is blank or unreadable; generator otherwise appears intact
Controller Power / Display Failure
Symptom
Coolant puddle under generator or sweet smell around unit
Coolant Leak
Symptom
Corrosion, rust, or rodent damage inside generator enclosure
Environmental / Pest Damage
Symptom
Fuel smell around generator or visible gas leak
Fuel Leak / Gas Odor
Symptom
Generator cranks but never fires (no attempt to start)
No-Start / No-Ignition Condition
Symptom
Generator enclosure vibrates excessively or walks on its pad during operation
Excessive Vibration
Symptom
Generator is excessively loud or has new knocking/metallic noises
Abnormal Mechanical Noise
Symptom
Generator runs but does not transfer power to the house
Automatic Transfer Switch (ATS) Fails to Transfer Load
Symptom
Generator runs its weekly exercise but never transfers load during real outages
Exercise-Only Operation / No Load Transfer
Symptom
Generator starts and transfers, then drops out and utility power returns repeatedly
Intermittent Transfer / Nuisance Drop-Out
Symptom
Generator starts but runs rough, surges, or hunts at no load
Unstable Engine Operation / Surging
Symptom
Generator will not start at all (no crank, no click) when utility fails
No-Start / No-Crank Condition
Symptom
Oil leaking under generator or oil spots on pad
Engine Oil Leak
Symptom
Strong exhaust smell or fumes inside the house when generator runs
Exhaust Fume Intrusion