RainSoft

RainSoft Water Softeners Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E1
Control panel displays E1 and unit will not start a regeneration cycle
Inlet Valve / Flow Sensor Fault
E10
E10 displayed, no communication between display module and main control board
Display / Keypad Communication Fault
E11
E11 error, unit loses time and settings after short power outages
Backup Power / Real-Time Clock Fault
E12
E12 displayed, high salt usage and frequent regenerations
Programming / Meter Calibration Fault
E13
E13 error, unit fails to initiate regeneration at scheduled time
Timer / Scheduling Fault
E14
E14 displayed, drain runs continuously and unit never returns to service
Stuck in Regeneration / Drain Valve Fault
E15
E15 error, low or no water pressure to the home when softener is in service
Internal Bypass / Service Flow Restriction Fault
E16
E16 displayed, high conductivity or hardness detected after softener
Outlet Water Quality Sensor Fault
E17
E17 error, salt level sensor alarm or inaccurate salt level reading
Brine Tank Salt Level Sensor Fault
E18
E18 displayed, high temperature detected at control head
Overtemperature / Thermal Sensor Fault
E19
E19 error, excessive regeneration time or cycle does not complete within expected duration
Regeneration Timeout Fault
E2
E2 displayed and unit will not advance through regeneration stages
Motor / Cam Drive Fault
E20
E20 displayed, internal leak detected between soft and hard water paths
Internal Valve Leakage Fault
E3
E3 error and display frozen, regeneration stops mid-cycle
Position Switch / Encoder Fault
E4
E4 displayed, unit does not keep correct time or program settings
Control Board / Memory Fault
E5
E5 error and no water flow is registered on the display even when water is being used
Flow Meter / Turbine Signal Loss
E6
E6 displayed, unit regenerates at incorrect intervals or not at all based on usage
Metered Regeneration Logic Fault
E7
E7 error and brine tank does not fill with water before regeneration
Brine Fill Valve / Brine Refill Circuit Fault
E8
E8 displayed, unit stuck in brine draw and does not advance
Brine Draw / Ejector Vacuum Fault
E9
E9 error and brine tank overfills with water, sometimes overflowing
Brine Refill Overrun / Float Safety Fault
Symptom
Brine tank fills with too much water between regenerations (no code)
Brine Tank Overfill
Symptom
Buttons on control panel are unresponsive or require excessive force
Keypad / Membrane Failure
Symptom
Control display is blank or intermittent but outlet has power
Power Supply / Display Failure
Symptom
Salt bridges in brine tank causing intermittent hard water
Salt Bridging / Salt Mushing
Symptom
Softener causes noticeable drop in water pressure only when in service (bypass restores pressure)
Flow Restriction Through Resin Bed
Symptom
Softener causes salty taste in water after regeneration
Insufficient Rinse / Brine Carryover
Symptom
Softener cycles at the wrong time of day (e.g., regenerates during peak water use)
Time-of-Day / Clock Misconfiguration
Symptom
Softener does not draw brine from the brine tank during regeneration (no code)
Brine Draw Failure
Symptom
Softener does not regenerate at all unless manually started
Regeneration Trigger Failure
Symptom
Softener emits rotten egg or foul odor in water
Bacterial Growth / Sulfur Contamination
Symptom
Softener installed but water tastes metallic or has staining despite softening
Inadequate Iron/Manganese Removal by Softener
Symptom
Softener is stuck in regeneration and continuously sends water to drain (no code)
Valve Stuck in Regeneration
Symptom
Softener makes loud clicking or grinding noises during regeneration
Gear Train / Motor Noise
Symptom
Softener regenerates too frequently, wasting salt and water (no code)
Over-Regeneration
Symptom
Softener stuck in bypass internally (water remains hard even though bypass is in service position)
Internal Bypass Valve Failure
Symptom
Visible resin beads appear in household faucets and aerators
Resin Loss into Plumbing
Symptom
Water remains hard even after recent regeneration (no error code displayed)
Resin Exhaustion or Resin Fouling
Symptom
Water softener leaks from around the control head
Control Valve External Leak
Symptom
Water softener leaks from the brine tank or brine line connections
Brine System External Leak
Advertisements