Simzlife
Simzlife Wine Coolers Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
dE
dE code and unit beeps with door symbol on display even when door is closed
Door Open Detection / Door Switch Fault
E0
Display shows E0 and the temperature cannot be adjusted or saved
Main Control Panel Keypad Communication Fault
E1
E1 error on display and cabinet temperature reading is inaccurate or stuck
Upper Compartment Temperature Sensor Failure
E2
E2 error on display and lower zone temperature does not regulate correctly
Lower Compartment Temperature Sensor Failure
E3
E3 error code and compressor cycles erratically or not at all
Ambient Temperature Sensor Fault
E4
E4 error code and interior fan does not run or runs intermittently
Evaporator Fan Motor Fault
E5
E5 error code and unit not cooling properly or shutting down unexpectedly
Compressor Overload / High Temperature Protection
E6
E6 error code and interior light or display flickers or goes out intermittently
Low Voltage / Power Supply Fault
E7
E7 error code and excessive frost buildup on back wall or around evaporator
Defrost Sensor or Defrost Circuit Fault
E8
E8 error code and unit runs continuously but does not reach set temperature
Refrigeration System Performance Fault
E9
E9 error code and interior humidity is very high with condensation on bottles and glass
Humidity Sensor or Humidity Control Fault
EC
Display shows EC and cooling stops; fans may still run
Compressor Drive or Inverter Board Fault
F1
F1 code and unit does not respond to temperature adjustments
Control Panel Key Stuck or Keypad Failure
F2
F2 code and compressor and fans do not start at all
Main Control Board Failure
H1
H1 code and temperature display shows unusually high readings even when interior feels cool
Upper Zone Sensor Short Circuit (High Temperature Indication)
H2
H2 code and lower zone temperature display is abnormally high or fluctuates rapidly
Lower Zone Sensor Short Circuit (High Temperature Indication)
Hi
Display shows Hi and unit does not cool even though compressor and fans may be running
High Temperature Alarm / Sensor Out of Range
L1
L1 code and interior light does not turn on when door opens
LED Light Circuit Fault
Lo
Display shows Lo and interior temperature is much colder than set point; bottles may be over‑chilled
Low Temperature Protection / Sensor Open Circuit
Symptom
Clicking noise from compressor area every few minutes and no cooling
Compressor Start Failure
Symptom
Condensation forming on the outside glass door
Door Glass Condensation
Symptom
Condenser fan at the back of the unit not running while compressor is hot
Condenser Fan Failure
Symptom
Display is completely blank and unit does not respond, but outlet has power
No Power to Control Panel
Symptom
Door does not close or seal properly; visible gap or door pops open
Door Alignment / Gasket Failure
Symptom
Excessive frost or ice buildup on the back wall or around the evaporator fan
Frost Buildup / Defrost System Failure
Symptom
Interior fan not running; cold spots near back wall and warm spots near door
Evaporator Fan Not Operating
Symptom
Interior light does not turn on at all, but cooling works normally
Interior Light Failure
Symptom
Interior light stays on even when the door is closed, causing extra heat inside
Door Switch Stuck Closed
Symptom
Loud humming, rattling, or vibrating noise during operation
Excessive Vibration / Noise
Symptom
Strong chemical or burning smell coming from the back of the wine cooler
Overheating Electrical Component
Symptom
Temperature display fluctuates rapidly or shows unrealistic values without error codes
Erratic Temperature Reading
Symptom
Temperature display is on but buttons do not respond to touch
Unresponsive Touch Controls
Symptom
Unit cycles on and off very frequently, with short run times and unstable temperature
Short Cycling
Symptom
Unit makes a gurgling or hissing sound periodically
Normal Refrigerant Flow Noise (Perceived Fault)
Symptom
Water pooling at the bottom of the cabinet or leaking onto the floor in front of the wine cooler
Drainage / Condensate Leak
Symptom
Wine cooler not cooling at all; interior at room temperature, lights and display may still work
No Cooling / Compressor Not Running
Symptom
Wine cooler runs but does not get cold enough; temperature stays well above set point with no error code
General Poor Cooling Performance
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| dE |
dE code and unit beeps with door symbol on display even when door is closed
|
Door Open Detection / Door Switch Fault | View Details |
| E0 |
Display shows E0 and the temperature cannot be adjusted or saved
|
Main Control Panel Keypad Communication Fault | View Details |
| E1 |
E1 error on display and cabinet temperature reading is inaccurate or stuck
|
Upper Compartment Temperature Sensor Failure | View Details |
| E2 |
E2 error on display and lower zone temperature does not regulate correctly
|
Lower Compartment Temperature Sensor Failure | View Details |
| E3 |
E3 error code and compressor cycles erratically or not at all
|
Ambient Temperature Sensor Fault | View Details |
| E4 |
E4 error code and interior fan does not run or runs intermittently
|
Evaporator Fan Motor Fault | View Details |
| E5 |
E5 error code and unit not cooling properly or shutting down unexpectedly
|
Compressor Overload / High Temperature Protection | View Details |
| E6 |
E6 error code and interior light or display flickers or goes out intermittently
|
Low Voltage / Power Supply Fault | View Details |
| E7 |
E7 error code and excessive frost buildup on back wall or around evaporator
|
Defrost Sensor or Defrost Circuit Fault | View Details |
| E8 |
E8 error code and unit runs continuously but does not reach set temperature
|
Refrigeration System Performance Fault | View Details |
| E9 |
E9 error code and interior humidity is very high with condensation on bottles and glass
|
Humidity Sensor or Humidity Control Fault | View Details |
| EC |
Display shows EC and cooling stops; fans may still run
|
Compressor Drive or Inverter Board Fault | View Details |
| F1 |
F1 code and unit does not respond to temperature adjustments
|
Control Panel Key Stuck or Keypad Failure | View Details |
| F2 |
F2 code and compressor and fans do not start at all
|
Main Control Board Failure | View Details |
| H1 |
H1 code and temperature display shows unusually high readings even when interior feels cool
|
Upper Zone Sensor Short Circuit (High Temperature Indication) | View Details |
| H2 |
H2 code and lower zone temperature display is abnormally high or fluctuates rapidly
|
Lower Zone Sensor Short Circuit (High Temperature Indication) | View Details |
| Hi |
Display shows Hi and unit does not cool even though compressor and fans may be running
|
High Temperature Alarm / Sensor Out of Range | View Details |
| L1 |
L1 code and interior light does not turn on when door opens
|
LED Light Circuit Fault | View Details |
| Lo |
Display shows Lo and interior temperature is much colder than set point; bottles may be over‑chilled
|
Low Temperature Protection / Sensor Open Circuit | View Details |
| – |
Clicking noise from compressor area every few minutes and no cooling
|
Compressor Start Failure | View Details |
| – |
Condensation forming on the outside glass door
|
Door Glass Condensation | View Details |
| – |
Condenser fan at the back of the unit not running while compressor is hot
|
Condenser Fan Failure | View Details |
| – |
Display is completely blank and unit does not respond, but outlet has power
|
No Power to Control Panel | View Details |
| – |
Door does not close or seal properly; visible gap or door pops open
|
Door Alignment / Gasket Failure | View Details |
| – |
Excessive frost or ice buildup on the back wall or around the evaporator fan
|
Frost Buildup / Defrost System Failure | View Details |
| – |
Interior fan not running; cold spots near back wall and warm spots near door
|
Evaporator Fan Not Operating | View Details |
| – |
Interior light does not turn on at all, but cooling works normally
|
Interior Light Failure | View Details |
| – |
Interior light stays on even when the door is closed, causing extra heat inside
|
Door Switch Stuck Closed | View Details |
| – |
Loud humming, rattling, or vibrating noise during operation
|
Excessive Vibration / Noise | View Details |
| – |
Strong chemical or burning smell coming from the back of the wine cooler
|
Overheating Electrical Component | View Details |
| – |
Temperature display fluctuates rapidly or shows unrealistic values without error codes
|
Erratic Temperature Reading | View Details |
| – |
Temperature display is on but buttons do not respond to touch
|
Unresponsive Touch Controls | View Details |
| – |
Unit cycles on and off very frequently, with short run times and unstable temperature
|
Short Cycling | View Details |
| – |
Unit makes a gurgling or hissing sound periodically
|
Normal Refrigerant Flow Noise (Perceived Fault) | View Details |
| – |
Water pooling at the bottom of the cabinet or leaking onto the floor in front of the wine cooler
|
Drainage / Condensate Leak | View Details |
| – |
Wine cooler not cooling at all; interior at room temperature, lights and display may still work
|
No Cooling / Compressor Not Running | View Details |
| – |
Wine cooler runs but does not get cold enough; temperature stays well above set point with no error code
|
General Poor Cooling Performance | View Details |
No matching codes found
Advertisements