Beko

Beko Air Conditioners Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E1
Indoor unit displays E1 and stops cooling; fan may still run but compressor does not start.
Indoor Room Temperature Sensor (NTC) Fault
E2
Indoor unit shows E2 and stops cooling or heating; unit may start then shut down after a short time.
Indoor Evaporator Coil Temperature Sensor Fault
E3
Indoor unit displays E3 and stops; outdoor unit may not start or may shut down quickly.
Outdoor Coil Temperature Sensor Fault
E4
Indoor unit shows E4 and stops; may occur during heating or cooling, often after running for some time.
Outdoor Discharge Pipe Temperature Sensor Fault
E5
Indoor unit displays E5; system may not start or may shut down shortly after startup.
Outdoor Ambient Temperature Sensor Fault
E6
Indoor unit shows E6; unit may not respond to remote or may not start cooling/heating.
Indoor–Outdoor Communication Failure
E7
Indoor unit displays E7; louver may not move or may be stuck in one position.
Indoor Louver Stepper Motor Fault
E8
Indoor unit shows E8; unit may stop and not restart until power is reset.
Indoor Fan Motor Fault / Overload
E9
Indoor unit displays E9; unit may shut down unexpectedly, often related to condensate issues.
Full Drain Pan / Float Switch Alarm (if equipped)
F0
Indoor unit shows F0 and stops; often occurs shortly after startup in cooling mode.
Refrigerant System Low Charge / Underload Protection
F1
Indoor unit displays F1; unit may run briefly then stop, often in heating mode.
Indoor Coil Frost / Freeze Protection Triggered
F2
Indoor unit shows F2; often associated with overheating or high temperature conditions.
Indoor Coil Overheat / High Temperature Protection
F3
Indoor unit displays F3; unit may stop during heating mode.
Outdoor Coil Overheat Protection
F4
Indoor unit shows F4; compressor may not start or may shut down quickly.
Compressor Discharge Overheat Protection
F5
Indoor unit displays F5; often associated with defrost or heating performance issues.
Outdoor Defrost Sensor / Defrost Protection Fault
H1
Indoor unit shows H1; heating does not start immediately, fan may run slowly or stop.
Defrost or Preheating Mode Indication (Protection, not always a fault)
H3
Indoor unit displays H3; compressor stops and unit may shut down.
Compressor Overload / Overcurrent Protection
H4
Indoor unit shows H4; unit may not start or may stop shortly after startup.
Inverter Module / IPM Protection
H5
Indoor unit displays H5; unit may not operate or may shut down intermittently.
IPM / Inverter Module Communication or Protection Fault
P0
Indoor unit shows P0; compressor may not start or may run at limited capacity.
DC Bus Voltage Protection / Power Supply Fault
P1
Indoor unit displays P1; unit may stop during operation, often in cooling mode.
High Pressure Protection
P2
Indoor unit shows P2; unit may stop or reduce capacity.
Low Pressure Protection
P4
Indoor unit displays P4; unit may not start or may shut down intermittently.
Inverter Module Overheat Protection
Symptom
Air conditioner runs but does not cool the room effectively
Insufficient Cooling Capacity / Performance Loss
Symptom
Air conditioner runs but does not heat the room effectively in heating mode
Insufficient Heating Capacity / Performance Loss
Symptom
Burning or electrical smell from indoor or outdoor unit
Overheating Electrical Component
Symptom
Frost or ice forming on the indoor coil during cooling
Evaporator Coil Freezing
Symptom
Indoor fan does not run, but unit powers on and compressor may start
Indoor Fan Motor Failure
Symptom
Indoor unit displays lights but does not respond to any commands
Indoor Control Panel / Microcontroller Lockup
Symptom
Indoor unit does not power on at all (no lights, no display)
No Power to Indoor Unit
Symptom
Indoor unit emits a musty or moldy smell when starting
Biological Growth on Indoor Coil or Drain Pan
Symptom
Indoor unit fan runs but no air comes out of some Beko multi-split indoor units
Zone / Indoor Unit Not Receiving Refrigerant
Symptom
Indoor unit frequently turns on and off (short cycling)
Short Cycling / Incorrect Capacity Control
Symptom
Loud humming or grinding noise from the outdoor unit
Outdoor Mechanical Noise / Fan or Compressor Issue
Symptom
Loud rattling or buzzing noise from the indoor unit
Indoor Mechanical Vibration / Loose Components
Symptom
Outdoor fan does not run while compressor is operating
Outdoor Fan Motor Failure
Symptom
Outdoor unit covered in ice during heating mode
Outdoor Coil Icing / Defrost Failure
Symptom
Remote control does not operate the Beko air conditioner
Remote Control / IR Receiver Failure
Symptom
Unit powers on but compressor and outdoor unit do not start
No Compressor Operation
Symptom
Unit trips the circuit breaker when starting
Electrical Overcurrent / Short Circuit
Symptom
Water leaking from the indoor unit onto the wall or floor
Indoor Condensate Drainage Failure
Symptom
Water leaking from the outdoor unit
Outdoor Condensate / Defrost Water Drainage Issue