F01
Dryer will not start, display shows F01 immediately or after pressing Start.
Main Control Board Communication / EEPROM Error
F02
Dryer stops shortly after start or will not start; display shows F02.
Motor Circuit Fault / Motor Relay Error
F03
Dryer does not heat properly or stops with F03 on the display.
NTC Temperature Sensor Fault (Inlet or Outlet)
F04
Dryer stops heating and displays F04 during a cycle.
Heater Relay / Heating Circuit Fault
F05
Dryer stops mid-cycle and shows F05; may not heat or may shut down quickly.
Exhaust / Condenser Temperature Sensor Fault
F06
Dryer does not start or stops with F06; sometimes accompanied by beeping.
Door Lock / Door Switch Fault
F07
Dryer stops and displays F07; may not heat or may shut down quickly after start.
Heater Overheat Protection / Thermostat Fault
F08
Dryer shows F08 and may not start or may stop shortly after starting.
Humidity Sensor / Moisture Sensor Fault
F09
Dryer displays F09 and may not start or may stop unexpectedly.
Software Configuration / EEPROM Parameter Error
F10
Dryer shows F10 and may not start or may stop with no drum movement.
Tachometer / Motor Speed Sensor Fault
F11
Dryer displays F11; may not respond to buttons or may freeze mid-cycle.
User Interface / Control Panel Communication Error
F12
Dryer shows F12 and may not start; sometimes appears after power interruptions.
Communication Error Between Control Boards
F13
Dryer displays F13; may stop heating or shut down unexpectedly.
Heat Pump System Fault (Heat Pump Models)
F14
Dryer shows F14 and does not heat properly, especially on heat pump models.
Heat Pump Temperature Sensor / Pressure Sensor Fault
F15
Dryer displays F15 and may not heat or may stop shortly after starting.
Heater Earth Leakage / Ground Fault
F18
Dryer shows F18 and may not start or may stop unexpectedly.
Power Supply / Voltage Fault
F20
Dryer displays F20 and may not start or may stop with no heating.
Exhaust Airflow / Blocked Filter Detection
F22
Dryer shows F22 and may not start or may stop with door-related beeps.
Door Locking System Error
F23
Dryer displays F23 and may stop heating or shut down.
Ambient Temperature Sensor Fault
F24
Dryer shows F24 and may not start or may stop with heating issues.
Overtemperature Detected by Control
F25
Dryer displays F25 and may not start or may stop mid-cycle.
Condensate Pump / Water Level Fault (Condenser/Heat Pump Models)
F26
Dryer shows F26 and may not start or may stop with unusual noises from the motor area.
Motor Overload / Overcurrent Fault
F27
Dryer displays F27 and may not start or may stop with irregular drum movement.
Reversing Motor Direction Fault
F28
Dryer shows F28 and may not start or may stop with sensor-dry programs failing.
Humidity Measurement Circuit Fault
F29
Dryer displays F29 and may not start or may stop with water-related issues.
Water Tank / Level Detection Fault
Symptom
Control panel buttons are unresponsive or only some buttons work intermittently.
User Interface Keypad Failure
Symptom
Dryer display shows unusually short or long remaining times that do not match actual drying progress.
Sensor Drying Algorithm / Moisture Sensing Issue
Symptom
Dryer door is difficult to open or does not stay closed properly during operation.
Door Latch / Hinge Wear
Symptom
Dryer door seal is torn or there is visible lint and moisture escaping around the door.
Door Gasket / Seal Damage
Symptom
Dryer drum does not turn, but you can hear the motor humming or the dryer clicks and then stops.
Drive Belt Slipped or Broken
Symptom
Dryer emits a high-pitched squealing or squeaking noise during operation.
Friction in Drum Support Components
Symptom
Dryer interior light does not work, but the dryer otherwise operates normally.
Drum Light Failure
Symptom
Dryer is very noisy during operation; banging, rumbling, or scraping sounds from the drum area.
Drum Support or Bearing Wear
Symptom
Dryer leaks water onto the floor, usually at the front or bottom (condenser/heat pump models).
Condensate Drainage Problem
Symptom
Dryer powers on but will not start when Start button is pressed; display may show normal time.
Start Circuit / Safety Interlock Issue
Symptom
Dryer produces a burning smell or smoke, especially from the rear or lint filter area.
Lint Ignition Risk / Overheating of Lint Deposits
Symptom
Dryer runs but clothes come out very hot and sometimes slightly scorched or with a burnt smell.
Overheating / Temperature Regulation Failure
Symptom
Dryer runs but does not heat; clothes remain cold and wet at the end of the cycle.
Heating System Failure
Symptom
Dryer runs but takes very long to dry clothes; laundry is still damp after a full cycle.
Restricted Airflow / Poor Drying Performance
Symptom
Dryer stops after a few minutes and clothes are still wet; no error code displayed.
Overheating and Safety Cut-Out Activation
Symptom
Dryer vibrates excessively or moves across the floor during operation.
Excessive Vibration / Imbalance
Symptom
Dryer will not start at all; no lights or display, completely dead.
No Power / Dead Appliance
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| F01 |
Dryer will not start, display shows F01 immediately or after pressing Start.
|
Main Control Board Communication / EEPROM Error | View Details |
| F02 |
Dryer stops shortly after start or will not start; display shows F02.
|
Motor Circuit Fault / Motor Relay Error | View Details |
| F03 |
Dryer does not heat properly or stops with F03 on the display.
|
NTC Temperature Sensor Fault (Inlet or Outlet) | View Details |
| F04 |
Dryer stops heating and displays F04 during a cycle.
|
Heater Relay / Heating Circuit Fault | View Details |
| F05 |
Dryer stops mid-cycle and shows F05; may not heat or may shut down quickly.
|
Exhaust / Condenser Temperature Sensor Fault | View Details |
| F06 |
Dryer does not start or stops with F06; sometimes accompanied by beeping.
|
Door Lock / Door Switch Fault | View Details |
| F07 |
Dryer stops and displays F07; may not heat or may shut down quickly after start.
|
Heater Overheat Protection / Thermostat Fault | View Details |
| F08 |
Dryer shows F08 and may not start or may stop shortly after starting.
|
Humidity Sensor / Moisture Sensor Fault | View Details |
| F09 |
Dryer displays F09 and may not start or may stop unexpectedly.
|
Software Configuration / EEPROM Parameter Error | View Details |
| F10 |
Dryer shows F10 and may not start or may stop with no drum movement.
|
Tachometer / Motor Speed Sensor Fault | View Details |
| F11 |
Dryer displays F11; may not respond to buttons or may freeze mid-cycle.
|
User Interface / Control Panel Communication Error | View Details |
| F12 |
Dryer shows F12 and may not start; sometimes appears after power interruptions.
|
Communication Error Between Control Boards | View Details |
| F13 |
Dryer displays F13; may stop heating or shut down unexpectedly.
|
Heat Pump System Fault (Heat Pump Models) | View Details |
| F14 |
Dryer shows F14 and does not heat properly, especially on heat pump models.
|
Heat Pump Temperature Sensor / Pressure Sensor Fault | View Details |
| F15 |
Dryer displays F15 and may not heat or may stop shortly after starting.
|
Heater Earth Leakage / Ground Fault | View Details |
| F18 |
Dryer shows F18 and may not start or may stop unexpectedly.
|
Power Supply / Voltage Fault | View Details |
| F20 |
Dryer displays F20 and may not start or may stop with no heating.
|
Exhaust Airflow / Blocked Filter Detection | View Details |
| F22 |
Dryer shows F22 and may not start or may stop with door-related beeps.
|
Door Locking System Error | View Details |
| F23 |
Dryer displays F23 and may stop heating or shut down.
|
Ambient Temperature Sensor Fault | View Details |
| F24 |
Dryer shows F24 and may not start or may stop with heating issues.
|
Overtemperature Detected by Control | View Details |
| F25 |
Dryer displays F25 and may not start or may stop mid-cycle.
|
Condensate Pump / Water Level Fault (Condenser/Heat Pump Models) | View Details |
| F26 |
Dryer shows F26 and may not start or may stop with unusual noises from the motor area.
|
Motor Overload / Overcurrent Fault | View Details |
| F27 |
Dryer displays F27 and may not start or may stop with irregular drum movement.
|
Reversing Motor Direction Fault | View Details |
| F28 |
Dryer shows F28 and may not start or may stop with sensor-dry programs failing.
|
Humidity Measurement Circuit Fault | View Details |
| F29 |
Dryer displays F29 and may not start or may stop with water-related issues.
|
Water Tank / Level Detection Fault | View Details |
| – |
Control panel buttons are unresponsive or only some buttons work intermittently.
|
User Interface Keypad Failure | View Details |
| – |
Dryer display shows unusually short or long remaining times that do not match actual drying progress.
|
Sensor Drying Algorithm / Moisture Sensing Issue | View Details |
| – |
Dryer door is difficult to open or does not stay closed properly during operation.
|
Door Latch / Hinge Wear | View Details |
| – |
Dryer door seal is torn or there is visible lint and moisture escaping around the door.
|
Door Gasket / Seal Damage | View Details |
| – |
Dryer drum does not turn, but you can hear the motor humming or the dryer clicks and then stops.
|
Drive Belt Slipped or Broken | View Details |
| – |
Dryer emits a high-pitched squealing or squeaking noise during operation.
|
Friction in Drum Support Components | View Details |
| – |
Dryer interior light does not work, but the dryer otherwise operates normally.
|
Drum Light Failure | View Details |
| – |
Dryer is very noisy during operation; banging, rumbling, or scraping sounds from the drum area.
|
Drum Support or Bearing Wear | View Details |
| – |
Dryer leaks water onto the floor, usually at the front or bottom (condenser/heat pump models).
|
Condensate Drainage Problem | View Details |
| – |
Dryer powers on but will not start when Start button is pressed; display may show normal time.
|
Start Circuit / Safety Interlock Issue | View Details |
| – |
Dryer produces a burning smell or smoke, especially from the rear or lint filter area.
|
Lint Ignition Risk / Overheating of Lint Deposits | View Details |
| – |
Dryer runs but clothes come out very hot and sometimes slightly scorched or with a burnt smell.
|
Overheating / Temperature Regulation Failure | View Details |
| – |
Dryer runs but does not heat; clothes remain cold and wet at the end of the cycle.
|
Heating System Failure | View Details |
| – |
Dryer runs but takes very long to dry clothes; laundry is still damp after a full cycle.
|
Restricted Airflow / Poor Drying Performance | View Details |
| – |
Dryer stops after a few minutes and clothes are still wet; no error code displayed.
|
Overheating and Safety Cut-Out Activation | View Details |
| – |
Dryer vibrates excessively or moves across the floor during operation.
|
Excessive Vibration / Imbalance | View Details |
| – |
Dryer will not start at all; no lights or display, completely dead.
|
No Power / Dead Appliance | View Details |
No matching codes found