De Dietrich

De Dietrich Dryers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Dryer will not start; display shows E01 immediately after pressing Start.
Door Lock / Door Switch Fault
E02
Dryer stops shortly after starting; display shows E02 and drum may not rotate.
Motor Start / Motor Overload Fault
E03
Dryer stops mid-cycle and displays E03; clothes remain wet and drum may be hot.
Overheating / Thermostat Trip Fault
E04
Dryer does not heat; cycle runs but clothes stay cold and E04 appears on the display.
Heating Element / Heater Circuit Fault
E05
Dryer stops and displays E05; may occur early in the cycle, often with no heat or incorrect temperature.
NTC Temperature Sensor Fault
E06
Dryer will not start or stops with E06; sometimes accompanied by unusual clicking from the control area.
Control Board / Relay Fault
E07
Dryer displays E07 and may stop heating; often associated with condenser or airflow issues on condenser/heat pump models.
Condenser / Airflow Sensor Fault
E08
Dryer shows E08 and may not start or may stop shortly after starting; often related to moisture sensing.
Moisture Sensor Circuit Fault
E09
Dryer displays E09 and may not heat or may shut down unexpectedly; more common on heat pump models.
Heat Pump / Compressor System Fault
E10
Dryer shows E10 and may not start; sometimes associated with water tank or drain issues on condenser models.
Condensate Pump / Water Level Fault
E11
Dryer displays E11 and may not respond to button presses or may behave erratically.
User Interface / Control Panel Communication Fault
E12
Dryer shows E12 and may stop heating or terminate cycles prematurely.
Exhaust / Ventilation Fault (Vented Models)
E13
Dryer displays E13; may be associated with internal water leaks on condenser/heat pump models.
Leak Detection / Overflow Fault
E14
Dryer shows E14 and may not start; often related to door locking sequence or safety interlocks.
Door Locking Sequence / Safety Interlock Error
E15
Dryer displays E15 and may stop mid-cycle; sometimes accompanied by unusual noises from the motor area.
Motor Tachometer / Speed Feedback Fault
E16
Dryer shows E16 and may not heat correctly; temperature seems unstable.
Heater Relay Stuck / Triac Fault
E17
Dryer displays E17; may be associated with internal communication between modules on advanced models.
Internal Communication Bus Fault
E18
Dryer shows E18 and may stop with a beeping alarm; often related to overcurrent or short circuit detection.
Power Supply / Overcurrent Fault
E19
Dryer displays E19; may be associated with incorrect configuration or memory error after power loss.
Configuration / EEPROM Fault
Symptom
Dryer display and lights flicker or reset during operation.
Intermittent Power / Voltage Drop
Symptom
Dryer door pops open during the cycle, stopping the program.
Door Latch / Catch Failure
Symptom
Dryer door will not open at the end of the cycle; door remains locked.
Door Lock Stuck Closed
Symptom
Dryer drum does not turn, but you can hear the motor humming when Start is pressed.
Drum Drive Failure
Symptom
Dryer drum light works but the drum does not turn and there is no motor sound.
Motor Not Running / Control or Motor Fault
Symptom
Dryer emits a burning smell during operation, with or without visible smoke.
Overheating / Lint Ignition Risk
Symptom
Dryer emits a rattling or metallic clinking noise while tumbling.
Foreign Object in Drum or Blower
Symptom
Dryer leaks water onto the floor during or after a cycle (condenser/heat pump models).
Condensate Leak
Symptom
Dryer leaves black or brown marks on clothes.
Drum Seal / Felt Contamination or Damage
Symptom
Dryer leaves lint all over clothes after drying.
Lint Filtration / Airflow Issue
Symptom
Dryer makes a low rumbling or grinding noise from the rear of the drum.
Rear Drum Bearing Wear (if equipped)
Symptom
Dryer makes loud squealing or screeching noises during operation.
Drum Support / Idler Pulley Wear
Symptom
Dryer produces a loud banging or thumping noise, especially with small loads.
Drum Support Imbalance / Flat-Spotted Rollers
Symptom
Dryer produces a musty or moldy smell on clothes after drying.
Odor / Bacterial Growth in Air Path
Symptom
Dryer runs but clothes come out very hot and sometimes wrinkled or slightly scorched.
Overheating / Temperature Regulation Failure
Symptom
Dryer runs but does not heat; clothes remain cold and damp at the end of the cycle, no error code displayed.
No Heat Condition Without Error
Symptom
Dryer stops mid-cycle and will not restart until it cools down.
Overheating / Motor or Thermostat Trip
Symptom
Dryer stops shortly after starting an automatic (sensor) program but works in timed mode.
Moisture Sensing Performance Issue
Symptom
Dryer takes too long to dry clothes; cycles complete but laundry is still slightly damp.
Extended Drying Time / Poor Drying Performance
Symptom
Dryer vibrates excessively and may move across the floor during operation.
Excessive Vibration / Installation Issue
Symptom
Dryer will not power on; display is completely dead.
No Power / Power Supply Failure
Symptom
Dryer will not start at all; display is on but Start button does nothing.
Start Circuit / Safety Interlock Issue
Advertisements