E01
Pump will not start, display shows E01 immediately when Start is pressed
Low Line Voltage / Undervoltage Protection
E02
Pump stops shortly after starting, display shows E02
Overvoltage Protection
E03
Pump display shows E03 and motor will not run
Phase Loss / Internal Power Stage Fault (for VS permanent magnet motor)
E04
Pump attempts to start then stops with E04 on the display
Overcurrent / Locked Rotor Protection
E05
Pump stops during operation and displays E05
Overtemperature / Drive Thermal Protection
E06
Pump display shows E06 and will not run
Internal Drive Fault / Self‑Test Failure
E07
Pump display shows E07, motor does not start or runs erratically
Motor Position / Speed Feedback Error
E08
Pump display shows E08 and stops running
Ground Fault / Leakage Current Detected
E09
Pump display shows E09 and will not accept speed changes
Keypad / User Interface Communication Error
E10
Pump display shows E10 and pump will not start
External Control Communication Error (Automation Interface Fault)
E11
Pump display shows E11 and speed drops or pump stops
Underload / Dry‑Run Protection
E12
Pump display shows E12 and pump shuts down intermittently
Overload / High Torque Protection
E13
Pump display shows E13 and pump will not start after a power event
Non‑Volatile Memory / Parameter Error
Symptom
Pump emits a burning smell and may smoke from the motor area
Overheated Motor Windings
Symptom
Pump housing is cracked and leaking water
Freeze Damage or Mechanical Stress Crack
Symptom
Pump hums but will not start (older single‑speed or two‑speed Sta‑Rite Max‑E‑Pro / Dyna‑Glas models)
Failed Start Capacitor or Stuck Start Switch
Symptom
Pump is noisy with a rattling or grinding sound from the wet end
Damaged Impeller or Loose Diffuser
Symptom
Pump is unusually loud only at high speed on variable‑speed model
Hydraulic Noise / Resonance at High RPM
Symptom
Pump is very noisy with a loud grinding or screeching sound
Worn Motor Bearings
Symptom
Pump leaks at the drain plugs on the bottom of the housing
Damaged or Missing Drain Plug O‑Rings
Symptom
Pump leaks water at the clamp band or housing seam
Failed Housing O‑Ring / Seal Plate Gasket
Symptom
Pump leaks water between the motor and pump housing
Failed Mechanical Shaft Seal
Symptom
Pump makes a loud cavitation or gravelly sound and the pump lid is full of air
Cavitation Due to Suction Restriction or High Lift
Symptom
Pump motor runs but impeller does not turn (no water movement)
Broken Shaft or Stripped Impeller Hub
Symptom
Pump runs but has very low flow and weak return jets
Hydraulic Restriction / Suction or Discharge Blockage
Symptom
Pump runs but pressure gauge on filter reads zero and there is no circulation
Air‑Bound System / No Discharge Flow
Symptom
Pump runs but spa jets are weak when in spa mode
Insufficient Flow in Spa Circuit
Symptom
Pump runs but there are lots of bubbles at the pool returns
Suction Side Air Leak
Symptom
Pump runs for a few minutes then trips the thermal overload and shuts off
Overheating Motor
Symptom
Pump trips the circuit breaker immediately when turned on
Electrical Short Circuit or Ground Fault
Symptom
Pump turns on and off repeatedly (short cycling)
Intermittent Power or Thermal Overload Cycling
Symptom
Pump vibrates excessively and moves on the pad during operation
Imbalance or Mounting Issue
Symptom
Pump will not prime; pump pot does not fill with water
Loss of Prime / Suction Air Leak
Symptom
Pump will not start after winter; motor is seized
Corroded or Frozen Motor / Impeller
Symptom
Variable‑speed pump display is blank but power is present at the breaker
No Low‑Voltage Power to User Interface
Symptom
Variable‑speed pump runs only at one speed and ignores programmed schedules
Control Logic / Programming Fault
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E01 |
Pump will not start, display shows E01 immediately when Start is pressed
|
Low Line Voltage / Undervoltage Protection | View Details |
| E02 |
Pump stops shortly after starting, display shows E02
|
Overvoltage Protection | View Details |
| E03 |
Pump display shows E03 and motor will not run
|
Phase Loss / Internal Power Stage Fault (for VS permanent magnet motor) | View Details |
| E04 |
Pump attempts to start then stops with E04 on the display
|
Overcurrent / Locked Rotor Protection | View Details |
| E05 |
Pump stops during operation and displays E05
|
Overtemperature / Drive Thermal Protection | View Details |
| E06 |
Pump display shows E06 and will not run
|
Internal Drive Fault / Self‑Test Failure | View Details |
| E07 |
Pump display shows E07, motor does not start or runs erratically
|
Motor Position / Speed Feedback Error | View Details |
| E08 |
Pump display shows E08 and stops running
|
Ground Fault / Leakage Current Detected | View Details |
| E09 |
Pump display shows E09 and will not accept speed changes
|
Keypad / User Interface Communication Error | View Details |
| E10 |
Pump display shows E10 and pump will not start
|
External Control Communication Error (Automation Interface Fault) | View Details |
| E11 |
Pump display shows E11 and speed drops or pump stops
|
Underload / Dry‑Run Protection | View Details |
| E12 |
Pump display shows E12 and pump shuts down intermittently
|
Overload / High Torque Protection | View Details |
| E13 |
Pump display shows E13 and pump will not start after a power event
|
Non‑Volatile Memory / Parameter Error | View Details |
| – |
Pump emits a burning smell and may smoke from the motor area
|
Overheated Motor Windings | View Details |
| – |
Pump housing is cracked and leaking water
|
Freeze Damage or Mechanical Stress Crack | View Details |
| – |
Pump hums but will not start (older single‑speed or two‑speed Sta‑Rite Max‑E‑Pro / Dyna‑Glas models)
|
Failed Start Capacitor or Stuck Start Switch | View Details |
| – |
Pump is noisy with a rattling or grinding sound from the wet end
|
Damaged Impeller or Loose Diffuser | View Details |
| – |
Pump is unusually loud only at high speed on variable‑speed model
|
Hydraulic Noise / Resonance at High RPM | View Details |
| – |
Pump is very noisy with a loud grinding or screeching sound
|
Worn Motor Bearings | View Details |
| – |
Pump leaks at the drain plugs on the bottom of the housing
|
Damaged or Missing Drain Plug O‑Rings | View Details |
| – |
Pump leaks water at the clamp band or housing seam
|
Failed Housing O‑Ring / Seal Plate Gasket | View Details |
| – |
Pump leaks water between the motor and pump housing
|
Failed Mechanical Shaft Seal | View Details |
| – |
Pump makes a loud cavitation or gravelly sound and the pump lid is full of air
|
Cavitation Due to Suction Restriction or High Lift | View Details |
| – |
Pump motor runs but impeller does not turn (no water movement)
|
Broken Shaft or Stripped Impeller Hub | View Details |
| – |
Pump runs but has very low flow and weak return jets
|
Hydraulic Restriction / Suction or Discharge Blockage | View Details |
| – |
Pump runs but pressure gauge on filter reads zero and there is no circulation
|
Air‑Bound System / No Discharge Flow | View Details |
| – |
Pump runs but spa jets are weak when in spa mode
|
Insufficient Flow in Spa Circuit | View Details |
| – |
Pump runs but there are lots of bubbles at the pool returns
|
Suction Side Air Leak | View Details |
| – |
Pump runs for a few minutes then trips the thermal overload and shuts off
|
Overheating Motor | View Details |
| – |
Pump trips the circuit breaker immediately when turned on
|
Electrical Short Circuit or Ground Fault | View Details |
| – |
Pump turns on and off repeatedly (short cycling)
|
Intermittent Power or Thermal Overload Cycling | View Details |
| – |
Pump vibrates excessively and moves on the pad during operation
|
Imbalance or Mounting Issue | View Details |
| – |
Pump will not prime; pump pot does not fill with water
|
Loss of Prime / Suction Air Leak | View Details |
| – |
Pump will not start after winter; motor is seized
|
Corroded or Frozen Motor / Impeller | View Details |
| – |
Variable‑speed pump display is blank but power is present at the breaker
|
No Low‑Voltage Power to User Interface | View Details |
| – |
Variable‑speed pump runs only at one speed and ignores programmed schedules
|
Control Logic / Programming Fault | View Details |