Viking Ice Makers Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E0
Ice maker will not run; display shows E0 shortly after power-up
No Fault Detected / Normal Startup Code
E1
Viking ice maker displays E1 and stops making ice
Evaporator Thermistor / Sensor Failure
E10
E10 error; unit may not recognize door/baffle position or may not start
Door Switch / Bin Switch Fault
E2
Viking ice maker shows E2 and shuts down ice production
Bin Thermistor / Ice Level Sensor Failure
E3
Display shows E3; ice maker stops mid-cycle or never completes harvest
Evaporator Temperature / Freeze Time Fault
E4
Viking ice maker displays E4 and shuts down; ice slab may be too thick or too thin
Harvest Fault / Ice Thickness Control Error
E5
E5 error on display; unit stops and may drain water repeatedly
Water Fill Timeout / Low Water Fault
E6
Viking ice maker shows E6; unit may not start or may shut down unexpectedly
High Temperature / Overheat Protection Fault
E7
E7 displayed; ice maker may run briefly then shut down
Compressor Protection / Current Fault
E8
E8 error; unit may not drain or may stop after a drain cycle
Drain Pump Fault / Drain Timeout
E9
E9 displayed; ice maker may not respond to controls or may behave erratically
Control Board Communication / Internal Fault
Symptom
Evaporator plate ices unevenly; one side thick, other side bare
Uneven Frost Pattern / Partial Restriction
Symptom
Ice appears cloudy or white instead of clear
Cloudy Ice / Entrained Air or Minerals
Symptom
Ice bin overflows; ice does not stop being produced
Bin Full Detection Failure
Symptom
Ice cubes are too large or clumped together
Thick Ice / Overfill Condition
Symptom
Ice has a bad taste or odor
Contaminated Ice / Water Quality Issue
Symptom
Ice maker cabinet feels hot to the touch on the sides or top
Cabinet Overheating / Condenser Venting Issue
Symptom
Ice maker cycles on and off rapidly without completing a full cycle
Short Cycling / Control or Sensor Issue
Symptom
Ice maker fills with too much water and overflows into the bin
Overfill / Water Level Control Failure
Symptom
Ice maker frequently freezes up with thick ice on the evaporator or in the bin
Freeze-Up / Defrost Drain or Airflow Issue
Symptom
Ice maker is leaking water onto the floor
External Water Leak
Symptom
Ice maker is very noisy during operation (grinding, rattling, or buzzing)
Excessive Operational Noise
Symptom
Ice maker makes ice but cubes are too small or thin
Thin Ice / Low Water Level
Symptom
Ice maker produces ice, but ice production is very slow
Reduced Ice Capacity / Inefficient Cooling
Symptom
Ice maker runs but does not produce any ice
No Ice Production / Cooling or Water Supply Fault
Symptom
Ice maker runs but ice melts quickly in the bin
Poor Ice Storage / Warm Bin
Symptom
Ice maker stops making ice even though bin is not full
False Bin Full / Premature Shutoff
Symptom
Ice maker trips the circuit breaker when it starts
Electrical Short / Overcurrent
Symptom
Ice maker vibrates excessively or rattles against cabinetry
Vibration / Installation Fault
Symptom
Loud humming or clicking from compressor area; ice maker not cooling properly
Compressor Start / Mechanical Fault
Symptom
Unit displays cleaning reminder or indicator and performance is reduced
Maintenance Required / Scale Buildup
Symptom
Unit displays lights but buttons do not respond or respond intermittently
User Interface / Keypad Failure
Symptom
Unit is on but compressor and pump never start; only lights are on
Control Lockout / Safety Interlock
Symptom
Unit runs continuously and does not enter standby even when bin is full
Continuous Operation / Control Fault
Symptom
Viking ice maker will not power on at all (no lights, no sounds)
No Power / Line Supply Fault
Symptom
Water pooling inside the ice bin or under the evaporator
Internal Leak / Poor Drainage
Symptom
Water pump runs but little or no water flows over the evaporator
Restricted Water Circulation
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E0 |
Ice maker will not run; display shows E0 shortly after power-up
|
No Fault Detected / Normal Startup Code | View Details |
| E1 |
Viking ice maker displays E1 and stops making ice
|
Evaporator Thermistor / Sensor Failure | View Details |
| E10 |
E10 error; unit may not recognize door/baffle position or may not start
|
Door Switch / Bin Switch Fault | View Details |
| E2 |
Viking ice maker shows E2 and shuts down ice production
|
Bin Thermistor / Ice Level Sensor Failure | View Details |
| E3 |
Display shows E3; ice maker stops mid-cycle or never completes harvest
|
Evaporator Temperature / Freeze Time Fault | View Details |
| E4 |
Viking ice maker displays E4 and shuts down; ice slab may be too thick or too thin
|
Harvest Fault / Ice Thickness Control Error | View Details |
| E5 |
E5 error on display; unit stops and may drain water repeatedly
|
Water Fill Timeout / Low Water Fault | View Details |
| E6 |
Viking ice maker shows E6; unit may not start or may shut down unexpectedly
|
High Temperature / Overheat Protection Fault | View Details |
| E7 |
E7 displayed; ice maker may run briefly then shut down
|
Compressor Protection / Current Fault | View Details |
| E8 |
E8 error; unit may not drain or may stop after a drain cycle
|
Drain Pump Fault / Drain Timeout | View Details |
| E9 |
E9 displayed; ice maker may not respond to controls or may behave erratically
|
Control Board Communication / Internal Fault | View Details |
| – |
Evaporator plate ices unevenly; one side thick, other side bare
|
Uneven Frost Pattern / Partial Restriction | View Details |
| – |
Ice appears cloudy or white instead of clear
|
Cloudy Ice / Entrained Air or Minerals | View Details |
| – |
Ice bin overflows; ice does not stop being produced
|
Bin Full Detection Failure | View Details |
| – |
Ice cubes are too large or clumped together
|
Thick Ice / Overfill Condition | View Details |
| – |
Ice has a bad taste or odor
|
Contaminated Ice / Water Quality Issue | View Details |
| – |
Ice maker cabinet feels hot to the touch on the sides or top
|
Cabinet Overheating / Condenser Venting Issue | View Details |
| – |
Ice maker cycles on and off rapidly without completing a full cycle
|
Short Cycling / Control or Sensor Issue | View Details |
| – |
Ice maker fills with too much water and overflows into the bin
|
Overfill / Water Level Control Failure | View Details |
| – |
Ice maker frequently freezes up with thick ice on the evaporator or in the bin
|
Freeze-Up / Defrost Drain or Airflow Issue | View Details |
| – |
Ice maker is leaking water onto the floor
|
External Water Leak | View Details |
| – |
Ice maker is very noisy during operation (grinding, rattling, or buzzing)
|
Excessive Operational Noise | View Details |
| – |
Ice maker makes ice but cubes are too small or thin
|
Thin Ice / Low Water Level | View Details |
| – |
Ice maker produces ice, but ice production is very slow
|
Reduced Ice Capacity / Inefficient Cooling | View Details |
| – |
Ice maker runs but does not produce any ice
|
No Ice Production / Cooling or Water Supply Fault | View Details |
| – |
Ice maker runs but ice melts quickly in the bin
|
Poor Ice Storage / Warm Bin | View Details |
| – |
Ice maker stops making ice even though bin is not full
|
False Bin Full / Premature Shutoff | View Details |
| – |
Ice maker trips the circuit breaker when it starts
|
Electrical Short / Overcurrent | View Details |
| – |
Ice maker vibrates excessively or rattles against cabinetry
|
Vibration / Installation Fault | View Details |
| – |
Loud humming or clicking from compressor area; ice maker not cooling properly
|
Compressor Start / Mechanical Fault | View Details |
| – |
Unit displays cleaning reminder or indicator and performance is reduced
|
Maintenance Required / Scale Buildup | View Details |
| – |
Unit displays lights but buttons do not respond or respond intermittently
|
User Interface / Keypad Failure | View Details |
| – |
Unit is on but compressor and pump never start; only lights are on
|
Control Lockout / Safety Interlock | View Details |
| – |
Unit runs continuously and does not enter standby even when bin is full
|
Continuous Operation / Control Fault | View Details |
| – |
Viking ice maker will not power on at all (no lights, no sounds)
|
No Power / Line Supply Fault | View Details |
| – |
Water pooling inside the ice bin or under the evaporator
|
Internal Leak / Poor Drainage | View Details |
| – |
Water pump runs but little or no water flows over the evaporator
|
Restricted Water Circulation | View Details |