TCL

TCL Air Conditioners Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E0
Indoor unit displays E0 and will not start cooling or heating
Indoor Unit EEPROM / Main PCB Communication Fault
E1
Indoor unit shows E1 and stops operation shortly after starting
Indoor / Outdoor Communication Failure
E2
Unit displays E2 and stops cooling; indoor fan may continue running
Indoor Evaporator Coil Freeze Protection / Anti-freeze Protection
E3
Indoor unit shows E3 and stops cooling; outdoor unit may shut down
Refrigerant System Overload / High Pressure Protection
E4
Unit displays E4 and stops heating or cooling; may restart after some time
Compressor Discharge Overheat Protection
E5
Indoor unit shows E5 and stops; may relate to overcurrent or voltage issues
Compressor Overcurrent / Overload Protection
E6
Indoor unit displays E6 and stops; often intermittent operation
Indoor Fan Motor Fault / Feedback Error
E7
Indoor unit shows E7 and does not respond to mode changes
Mode Conflict / Indoor-Outdoor Mode Mismatch
E8
Unit displays E8 and stops; may relate to overload or high temperature
Indoor Unit Overload / Overheat Protection
E9
Indoor unit shows E9 and may shut down unexpectedly
Water Level Protection / Full Drain Pan Alarm (for some TCL models)
F0
TCL portable or split AC shows F0 and stops cooling
Low Refrigerant / Refrigerant Leakage Protection
F1
Indoor display shows F1 and unit stops or runs erratically
Indoor Ambient Temperature Sensor Fault
F2
Indoor unit shows F2 and may stop cooling or heating
Evaporator Coil Temperature Sensor Fault
F3
Unit displays F3 and may stop heating or cooling
Outdoor Ambient Temperature Sensor Fault
F4
Display shows F4 and outdoor unit may not run correctly
Outdoor Condenser Coil Temperature Sensor Fault
F5
Unit shows F5 and may limit operation in extreme temperatures
Outdoor Unit Overload / High Ambient Protection
F6
Indoor unit displays F6 and cooling capacity is reduced
Indoor Fan Speed Out of Control / Feedback Error
F7
Unit shows F7 and may not start compressor
Outdoor Fan Motor Fault / Feedback Error
F8
Display shows F8 and unit may limit operation or shut down
Indoor Unit Overheat / Overload Protection (Alternate Code)
F9
Unit shows F9 and may not control temperature correctly
Indoor Humidity / Additional Sensor Fault (model-dependent)
H0
Display shows H0 and unit may not start compressor
EEPROM Parameter Error / PCB Configuration Fault
H1
Unit shows H1 and does not blow warm air immediately in heating mode
Defrost / Preheating Indication (often normal operation)
H2
Display shows H2 and heating performance is poor
Defrost Protection / Outdoor Coil Overheat (model-dependent)
H3
Unit shows H3 and stops; compressor may be very hot
Compressor Overload Protection / Overheat
H4
Display shows H4 and unit will not run normally
Inverter Module / Drive Error
H5
Unit shows H5 and compressor does not start
Current Protection / IPM Protection
P0
TCL portable AC shows P0 and stops cooling
Low Voltage Protection / Power Supply Error
P1
TCL portable AC displays P1 and stops; water full indicator may be on
Full Condensate Tank / Water Level Protection
P2
Portable AC shows P2 and stops cooling intermittently
High Temperature Protection / Compressor Overheat (portable models)
P4
Portable AC displays P4 and stops
Drain Pump Fault (for pump-equipped models)
Symptom
Air conditioner does not turn on at all; no lights or display
No Power / Power Supply Failure
Symptom
Air conditioner runs but does not cool the room effectively
Insufficient Cooling Capacity / Performance Degradation
Symptom
Burning or electrical smell from indoor or outdoor unit
Overheating Electrical Component / Insulation Burn
Symptom
Frost or ice forming on the indoor evaporator coil
Evaporator Icing / Low Airflow or Refrigerant Issue
Symptom
Indoor unit vibrates excessively and transmits noise to the wall
Excessive Vibration / Mounting Issue
Symptom
Loud humming or grinding noise from outdoor unit
Outdoor Mechanical Noise / Fan or Compressor Issue
Symptom
Loud rattling or buzzing noise from indoor unit during operation
Indoor Mechanical Noise / Loose Components
Symptom
Outdoor unit coil covered in thick ice during heating mode
Outdoor Coil Icing / Defrost Failure
Symptom
Remote control does not operate the TCL air conditioner
Remote Control / IR Receiver Failure
Symptom
Unit blows air but temperature does not change between modes
Reversing Valve Failure (Heat Pump Models)
Symptom
Unit frequently turns on and off (short cycling)
Short Cycling / Control or Sizing Issue
Symptom
Unit powers on but compressor and outdoor fan never start
Compressor Not Starting / Control Signal Failure
Symptom
Unpleasant musty or moldy smell when the air conditioner starts
Biological Contamination / Mold in Evaporator and Drain
Symptom
Water dripping from the front of the indoor unit or from the air outlet
Indoor Water Leakage / Drainage Failure
Symptom
Water leaking from the outdoor unit base or around connections
Outdoor Water Leakage / Defrost or Condensate Drain Issue
Advertisements