Beko Humidifiers & Dehumidifiers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E1
Dehumidifier will not start and displays E1 on the control panel
Room Temperature Sensor Failure
E2
Dehumidifier stops and displays E2 on the screen, fan may still run briefly
Evaporator Coil Temperature Sensor Failure
E3
Dehumidifier shows E3 and compressor does not start
Humidity Sensor (RH Sensor) Failure
E4
Dehumidifier displays E4 and shuts down, often after running for a short time
Refrigeration System Protection / High or Low Temperature Fault
E5
Dehumidifier shows E5 and will not start dehumidifying
Water Level Sensor / Float Switch Fault
E6
Dehumidifier displays E6 and compressor does not run
Compressor Overload or Start Protection Fault
E7
Dehumidifier shows E7 and stops operation, fan may still run
Fan Motor or Fan Feedback Fault
E8
Dehumidifier displays E8 and shuts down shortly after starting
Defrost Sensor or Defrost Circuit Fault
E9
Dehumidifier shows E9 and will not run, often immediately at power‑on
EEPROM / Control Board Memory Error
EC
Dehumidifier shows EC and does not dehumidify properly
Refrigerant System / Low Refrigerant or Sensor Error
F0
Dehumidifier displays F0 and does not start dehumidifying
General Sensor Fault / Sensor Circuit Open
F1
Dehumidifier shows F1 and runs only in limited modes or not at all
Keypad / Control Panel Communication Fault
F2
Dehumidifier displays F2 and cannot be controlled properly
Communication Error Between Main PCB and Display Board
H1
Dehumidifier displays H1 and will not start or stops shortly after starting
High Temperature Protection / Overheat Fault
H2
Dehumidifier shows H2 and stops, often in cold rooms
Low Temperature Protection / Anti‑Frost Lockout
HI
Dehumidifier displays HI and may run continuously without reaching set humidity
High Humidity or Sensor Over‑Range Indication
LO
Dehumidifier displays LO and does not start dehumidifying
Low Humidity or Low Temperature Indication
P1
Dehumidifier shows P1 and stops dehumidifying, water tank may be empty
Continuous Drain Mode / Water Tank Position Error
P2
Dehumidifier displays P2 and stops, even though the tank is not full
Water Pump or Pump Float Fault (for models with built‑in pump)
Symptom
Dehumidifier display shows incorrect room humidity (far from actual)
Humidity Reading Calibration Error
Symptom
Dehumidifier display works but buttons do not respond or respond intermittently
Keypad / Touch Control Failure
Symptom
Dehumidifier does not power on at all, no lights or display
No Power / Input Power Failure
Symptom
Dehumidifier emits a burning smell or hot plastic odor
Overheating Component / Electrical Overload
Symptom
Dehumidifier emits a high‑pitched whine or buzzing from the compressor area
Compressor or Refrigerant Flow Noise
Symptom
Dehumidifier fan runs but there is no air coming out of the front grille
Airflow Blockage
Symptom
Dehumidifier frequently turns on and off in short cycles
Short Cycling
Symptom
Dehumidifier has a musty or moldy smell from the air outlet
Microbial Growth in Water System
Symptom
Dehumidifier hums but fan does not start spinning
Fan Motor Start Failure
Symptom
Dehumidifier leaks water onto the floor from the base or rear
Water Leakage / Drainage Fault
Symptom
Dehumidifier makes loud rattling or vibrating noises during operation
Excessive Vibration / Mechanical Noise
Symptom
Dehumidifier powers on but compressor never starts, fan runs continuously
Compressor Not Starting
Symptom
Dehumidifier runs but collects very little or no water
Poor Dehumidification Performance
Symptom
Dehumidifier runs but ice builds up heavily on the evaporator coil
Evaporator Icing / Defrost Failure
Symptom
Dehumidifier runs but the room humidity does not decrease
Ineffective Dehumidification
Symptom
Dehumidifier shuts off and indicates full tank even when the tank is empty
False Full Tank Detection
Symptom
Dehumidifier timer function does not work or unit does not start/stop at set times
Timer / Control Logic Fault
Symptom
Dehumidifier trips the household circuit breaker or RCD when turned on
Electrical Short or Earth Leakage
Symptom
Water tank fills too quickly or overflows despite continuous drain hose connected
Continuous Drain Malfunction