E1
Avanti ice maker will not power on, display shows E1 shortly after plugging in, no fans or compressor start.
High Temperature Sensor (Thermistor) Failure or Open Circuit
E10
Avanti ice maker displays E10 and will not start an ice cycle; control panel may still respond.
Door / Lid Switch Fault
E11
Display shows E11, unit beeps and stops; sometimes occurs during harvest when ice should drop.
Ice Bin Full Sensor / Infrared Beam Fault
E12
Avanti ice maker shows E12 and stops; may occur after a power surge or outage.
EEPROM / Control Board Memory Error
E2
Avanti ice maker displays E2 and stops making ice; fan may run but compressor does not start or shuts down quickly.
Low Temperature Sensor (Bin or Evaporator Thermistor) Failure
E3
Display shows E3, ice production stops, unit may start then shut off after a short time.
Ambient Temperature Sensor Fault
E4
Avanti ice maker shows E4 and stops mid-cycle; water may fill but ice does not harvest or unit shuts down.
Defrost / Evaporator Overfreeze Protection Fault
E5
Display shows E5, unit may power on but will not start an ice-making cycle.
Water Supply / Water Level Sensor Fault
E6
Avanti ice maker displays E6 and stops; unit may fill with water but does not freeze or harvest properly.
Ice Thickness Sensor / Probe Fault
E7
Display shows E7, ice maker stops and may beep; fan or compressor may not start.
Fan Motor or Fan Feedback Fault
E8
Avanti ice maker shows E8 and shuts down; unit may attempt to start then immediately stop.
Compressor Overload / High Current Protection Fault
E9
Display shows E9, unit may run briefly then stop; ice production is halted.
Low Refrigerant / Refrigeration System Performance Fault (Temperature Not Reached)
H1
Display shows H1 or 'HI', unit may stop making ice; interior feels warm.
High Temperature Alarm
L1
Display shows L1 or 'LO', ice production is slow or stops; interior may be too cold or sensor misreading.
Low Temperature Alarm / Sensor Out-of-Range
Symptom
Avanti ice maker does not turn on at all, no lights or display, completely dead.
No Power / Main Power Supply Failure
Symptom
Avanti ice maker fills with water but does not freeze; water stays liquid and drains away.
No Cooling / Refrigeration System Failure
Symptom
Avanti ice maker frequently trips the household circuit breaker or GFCI outlet.
Electrical Short / Ground Fault
Symptom
Avanti ice maker has power but will not start making ice when turned on; display appears normal.
Control Logic / Start Circuit Fault
Symptom
Avanti ice maker ice cubes are fused together in large clumps in the bin.
Ice Clumping / Bin Temperature Too Warm or No Harvest Breakup
Symptom
Avanti ice maker is very noisy during operation, with rattling, buzzing, or grinding sounds.
Excessive Noise / Mechanical Vibration
Symptom
Avanti ice maker leaks water onto the floor from underneath the unit.
External Water Leak
Symptom
Avanti ice maker makes a loud knocking or banging sound when the compressor starts or stops.
Compressor Start/Stop Noise
Symptom
Avanti ice maker makes ice but cubes are hollow or have large holes in the center.
Hollow Ice Cubes / Fast Freeze with Low Water
Symptom
Avanti ice maker makes ice but cubes are very small or thin and melt quickly.
Thin Ice / Insufficient Freeze Time
Symptom
Avanti ice maker makes ice but production is very slow; bin never fills completely.
Reduced Ice Production / Marginal Cooling
Symptom
Avanti ice maker produces cloudy ice instead of clear cubes.
Cloudy Ice / Entrained Air and Minerals
Symptom
Avanti ice maker runs a cleaning cycle repeatedly or will not exit cleaning mode.
Stuck in Cleaning Mode / Control Panel Fault
Symptom
Avanti ice maker runs but makes no ice at all; water does not appear in the ice-making area.
No Water Fill / Water Supply Failure
Symptom
Avanti ice maker stops making ice even though the bin is not full; restarting the unit temporarily restores operation.
Intermittent Shutdown / Overheat or Sensor Trip
Symptom
Avanti ice maker vibrates excessively and may move or rattle against surrounding cabinets.
Excessive Vibration
Symptom
Avanti ice maker's bin overflows with ice and does not stop making ice even when full.
Bin Full Control Failure
Symptom
Avanti ice maker's compressor runs continuously and does not cycle off; ice may be too hard or frost builds up.
Compressor Runs Constantly
Symptom
Avanti ice maker's display or indicator lights do not work, but the unit still makes ice.
Display / User Interface Failure
Symptom
Avanti ice maker's fan does not run, but compressor gets very hot and unit makes little or no ice.
Condenser Fan Failure
Symptom
Avanti ice maker's fan runs but compressor does not start; no cooling occurs.
Compressor Not Starting
Symptom
Avanti ice maker's water pump is very loud or does not circulate water over the evaporator plate.
Water Circulation Pump Failure
Symptom
Buttons on the Avanti ice maker control panel do not respond or respond intermittently.
Keypad / Button Failure
Symptom
Ice from the Avanti ice maker has a bad taste or odor.
Contaminated Ice / Taste and Odor Issue
Symptom
Water is pooling inside the Avanti ice maker cabinet or ice bin, but not leaking to the floor.
Internal Leak / Drainage Problem