E1
Dehumidifier will not start and displays E1 on the control panel
Room Temperature Sensor Failure
E2
Dehumidifier stops and displays E2, fan may still run briefly
Evaporator Coil Temperature Sensor Failure
E3
Dehumidifier shows E3 and compressor does not start
Humidity Sensor (RH Sensor) Failure
E4
Dehumidifier stops and displays E4, often after running for a short time
Refrigeration System Protection / High or Low Temperature Fault
E5
Dehumidifier displays E5 and will not dehumidify
Compressor Overload or Current Protection Fault
E6
Dehumidifier shows E6 and stops operation
Communication Error Between Display Board and Main PCB
E7
Dehumidifier displays E7 and will not start dehumidification
Fan Motor Feedback / Fan Lock Protection
E8
Dehumidifier shows E8 and stops, often accompanied by ice on the evaporator
Defrost Sensor or Defrost Protection Fault
E9
Dehumidifier displays E9 and will not run
Internal Memory or EEPROM Error
EC
Dehumidifier shows EC and stops dehumidifying
Refrigerant System Leak or Low Pressure Protection
F0
Dehumidifier displays F0 and does not respond to controls
Keypad or Touch Panel Fault
F1
Dehumidifier shows F1 and runs only in a limited mode or not at all
Internal Fan Speed Feedback Error
F2
Dehumidifier displays F2 and stops, often related to low temperature operation
Low Ambient Temperature Protection / Frost Protection Error
H1
Humidifier displays H1 and stops adding moisture
Low Water Level Protection / Empty Tank
H2
Humidifier shows H2 and does not produce mist
Ultrasonic Transducer (Nebulizer) Fault
H3
Humidifier displays H3 and shuts down shortly after starting
Overheat Protection / Temperature Sensor Fault in Humidifier Base
H4
Humidifier shows H4 and no mist is produced, fan may still run
Water Pump or Flow Sensor Fault (for models with circulation pump)
H5
Humidifier displays H5 and beeps, controls may be locked
Humidity Sensor Error in Humidifier
P1
Dehumidifier displays P1 and stops, water tank is empty or not full
Internal Condensate Sump High-Level Protection
P2
Dehumidifier shows P2 and stops, usually when tank is full
Water Tank Full Protection / Tank Switch Fault
Symptom
Dehumidifier display works but buttons do not respond or respond intermittently
Unresponsive Control Panel
Symptom
Dehumidifier does not power on at all, no lights or display
No Power / Input Power Failure
Symptom
Dehumidifier fan does not run, but compressor may start and overheat
Fan Not Running
Symptom
Dehumidifier leaks water onto the floor from the bottom or sides
Water Leakage / Drainage Fault
Symptom
Dehumidifier makes loud rattling or grinding noises during operation
Mechanical Noise / Fan or Compressor Mounting Fault
Symptom
Dehumidifier powers on but compressor never starts, only fan runs continuously
Compressor Not Starting
Symptom
Dehumidifier runs but does not collect water, humidity does not decrease
No Dehumidification / Poor Moisture Removal
Symptom
Dehumidifier shows incorrect room humidity (e.g., always 30% or 80%)
Humidity Reading Inaccurate
Symptom
Dehumidifier stops after a few minutes and restarts repeatedly
Short Cycling
Symptom
Dehumidifier vibrates excessively and may move on the floor
Excessive Vibration
Symptom
Humidifier emits unpleasant or moldy odor during operation
Odor / Microbial Growth in Water System
Symptom
Humidifier fan runs but no mist exits the outlet, mist accumulates inside
Blocked Mist Outlet / Internal Condensation
Symptom
Humidifier is on but produces no mist at all
No Mist Production
Symptom
Humidifier is very noisy, with buzzing or rattling sounds
Mechanical Noise in Humidifier
Symptom
Humidifier leaves white dust on nearby furniture
Mineral Dust Emission
Symptom
Humidifier or dehumidifier emits a burning smell or visible smoke
Electrical Overheating / Component Failure
Symptom
Humidifier produces very weak mist compared to normal
Reduced Mist Output
Symptom
Humidifier shuts off unexpectedly even though there is water in the tank
Intermittent Power or Level Detection Fault
Symptom
Humidifier water tank leaks when removed or when installed
Water Tank Leakage