Intergas Boilers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
Symptom
Boiler in standby, no central heating or hot water demand active, display shows code 0
Standby / No Heat Demand
1
Boiler shows code 1, burner on for central heating or hot water, but user suspects poor performance
Normal Operation / Burner Active
10
Boiler displays error code 10 and will not start, no heating or hot water
Flow Temperature Sensor (CH NTC) Fault
11
Boiler displays error code 11, boiler locks out, no heating or hot water
Return Temperature Sensor (CH Return NTC) Fault
12
Boiler displays error code 12, hot water temperature unstable or boiler locks out on DHW demand
DHW Temperature Sensor (DHW NTC) Fault
13
Boiler displays error code 13, intermittent hot water temperature spikes or shutdown
Cold Water Inlet Sensor / Flow Sensor Temperature Fault
2
Boiler shows code 2, pump running but burner off, boiler appears to be in pump overrun or post-purge
Pump Overrun / Post-Heating Circulation
20
Boiler displays error code 20, boiler locks out, no heating or hot water
Flame Detection Fault / Flame Signal Lost
21
Boiler displays error code 21, ignition attempts fail, no flame established
Ignition Failure
22
Boiler displays error code 22, burner shuts down unexpectedly during operation
Flame Loss During Operation
23
Boiler displays error code 23, fan runs abnormally or boiler will not fire
Fan Speed / Air Pressure Fault
24
Boiler displays error code 24, boiler locks out, no heating or hot water
Water Pressure Sensor / Flow Switch Fault
25
Boiler displays error code 25, boiler overheats and shuts down
Overheat Protection / High Limit Trip
26
Boiler displays error code 26, frequent cycling and shutdown on temperature
Flow Temperature Too High / Flow Restriction
27
Boiler displays error code 27, burner output limited, poor heating performance
Modulation / Gas Valve Control Fault
28
Boiler displays error code 28, boiler will not start, control panel unresponsive or erratic
PCB / Control Board Fault
29
Boiler displays error code 29, low system pressure, boiler shuts down
Low Water Pressure Lockout
3
Boiler shows code 3, fan running but no ignition, boiler does not fire
Pre-Purge / Ignition Sequence Not Completing
30
Boiler displays error code 30, pressure rises rapidly when heating, then discharges via safety valve
Overpressure / Expansion Vessel Failure
4
Boiler shows code 4, burner off, pump may run briefly, no heating or hot water
No Heat Demand / End of Cycle
40
Boiler displays error code 40, no heating or hot water, fan does not start
Fan Fault / No Airflow
41
Boiler displays error code 41, intermittent fan operation, boiler locks out
Fan Speed / Tachometer Fault
5
Boiler shows code 5, burner off, pump may run, boiler appears to be in anti-cycling delay
Anti-Cycling / Minimum Off Time
50
Boiler displays error code 50, no heating or hot water, pump not running
Pump Fault / No Circulation
51
Boiler displays error code 51, pump runs continuously even with no demand
Pump Overrun Control Fault
6
Boiler shows code 6, burner off, pump running, boiler cooling down after demand
Pump Overrun / Post-Heating Cool Down
60
Boiler displays error code 60, hot water priority fault on combi or system with priority control
DHW Priority / Diverter Control Fault
7
Boiler shows code 7, burner off, no demand, frost protection or anti-legionella cycle may be active
Frost Protection / Special Operating Mode
70
Boiler displays error code 70, communication error between user interface and main PCB
Communication / Display Board Fault
Symptom
Boiler condensate pipe repeatedly freezes in cold weather, causing lockouts
Frozen Condensate Pipe
Symptom
Boiler emits a burning smell or plastic smell when running
Overheating Component / Electrical Overload
Symptom
Boiler flue terminal has white staining or water dripping excessively
Condensate / Flue Gas Condensation Issue
Symptom
Boiler frequently loses pressure and needs topping up every few days
Chronic Pressure Loss
Symptom
Boiler leaking water from underneath the casing or from pipe connections
Internal Water Leak
Symptom
Boiler makes gurgling noises, especially at startup or shutdown
Air in System / Condensate Gurgling
Symptom
Boiler makes loud banging or knocking noises (kettling) during operation
Kettling / Localised Boiling in Heat Exchanger
Symptom
Boiler occasionally trips the household RCD or blows fuses
Electrical Short / Earth Leakage
Symptom
Boiler repeatedly turns on and off in short cycles without reaching set temperature
Short Cycling
Symptom
Boiler runs but radiators do not heat up, hot water may still work on combi models
No Central Heating Output
Symptom
Boiler runs for hot water but central heating only works when a hot tap is opened (on combi models)
Diverter Valve Stuck in DHW Position
Symptom
Boiler vibrates excessively or resonates through the pipework when running
Mechanical Vibration / Resonance
Symptom
Boiler will not start at all, display is blank or very dim
No Power / Dead Boiler
Symptom
Hot water temperature fluctuates between hot and cold during use
Unstable DHW Temperature Control
Symptom
Radiators only get warm at the bottom or some radiators stay cold while boiler runs
Poor Circulation / Sludged System