E01
Dryer will not start, display shows E01 immediately after pressing start
Door Lock / Door Switch Fault
E02
Dryer stops shortly after starting, E02 displayed, sometimes with beeping
Overheating / Thermistor or NTC Sensor Fault
E03
Dryer stops mid-cycle, clothes still wet, E03 displayed
Moisture Sensor / Dryness Detection Fault
E04
Dryer does not heat, cycle ends quickly, E04 displayed
Heating Circuit Failure (Heater or Thermal Fuse)
E05
Dryer stops, E05 displayed, sometimes accompanied by unusual humming or no drum movement
Motor Start / Motor Overload Fault
E06
Dryer stops and displays E06, often early in the cycle, sometimes with no heat
Airflow / Exhaust System Fault
E07
Dryer shows E07 and will not start or stops shortly after starting
Water Tank Full / Condensate Pump Fault (Condenser & Heat Pump Models)
E08
Heat pump dryer shows E08, runs but does not dry properly, often with low or no heat
Heat Pump System Fault (Compressor / Refrigerant Circuit)
E09
Dryer displays E09 and will not start, sometimes after a power surge or outage
Main Control Board Communication / Internal Error
E10
Dryer shows E10, often related to sensor or configuration issues, may not start certain programs
Configuration / Program Parameter Error
E11
Dryer displays E11 and may stop heating or terminate cycle prematurely
Exhaust Temperature Too High / Safety Thermostat Tripped
E12
Dryer shows E12, often with poor drying performance and long cycle times
Inlet Air Temperature / Ambient Sensor Fault
E13
Dryer displays E13, may stop and beep, sometimes associated with water handling on condenser/heat pump models
Condensate Level / Overflow Protection Fault
E14
Dryer shows E14 and may not respond to button presses correctly
User Interface / Keypad Fault
E15
Dryer displays E15, may not start or may stop unexpectedly
Door Lock Circuit / Safety Interlock Error
E16
Dryer shows E16, often related to internal communication between boards
Communication Error Between Main Control and Sub-Board
E17
Dryer displays E17, may not heat correctly or may shut down
Humidity / Dryness Sensor Calibration Error
E18
Dryer shows E18, often with no drum rotation or erratic motor behavior
Motor Tachometer / Speed Sensor Fault
E19
Dryer displays E19, may not start or may shut down unexpectedly
Power Supply / Voltage Error
E20
Dryer shows E20, often with issues related to water handling on condenser/heat pump models
Condensate Pump Overload / Blockage
Symptom
Dryer control panel buttons are unresponsive or respond intermittently
User Interface / Touch Control Failure
Symptom
Dryer display and lights are dead; unit shows no signs of power
No Power / Main Supply or Fuse Issue
Symptom
Dryer display shows time remaining but the drum and motor do not run; only a faint click is heard
Motor Start Failure
Symptom
Dryer door will not open at the end of the cycle; door seems locked even though the machine is off
Door Lock Mechanism Stuck
Symptom
Dryer drum does not turn, but you can hear the motor humming or the dryer clicks and then stops
Broken or Slipped Drive Belt
Symptom
Dryer emits a burning smell or hot plastic odor during operation
Overheating / Lint or Object Contact with Heater
Symptom
Dryer interior light does not turn on when the door is opened, but dryer otherwise works
Drum Light Circuit Failure
Symptom
Dryer leaks water onto the floor during or after a cycle (condenser and heat pump models)
Condensate Drainage / Tank System Leak
Symptom
Dryer leaves a layer of lint on clothes or excessive lint in the drum after cycles
Lint Filtration / Airflow Issue
Symptom
Dryer makes loud squealing, screeching, or grinding noises during operation
Drum Support Roller / Bearing Wear
Symptom
Dryer produces a rattling or clinking noise, especially at low speeds
Foreign Objects in Drum or Blower
Symptom
Dryer runs but does not heat; clothes come out cold and wet, no error code displayed
Heating Element or Thermal Fuse Failure
Symptom
Dryer runs continuously and does not stop at the expected time; clothes may be over-dried
Moisture Sensor Not Detecting Dryness
Symptom
Dryer stops after a few minutes and clothes are still very wet, no error code shown
Overheating Protection Trip
Symptom
Dryer takes too long to dry or never fully dries clothes, but appears to heat normally
Restricted Airflow / Poor Ventilation
Symptom
Dryer vibrates excessively or thumps loudly, especially during start or with heavy loads
Drum Imbalance / Support Wear
Symptom
Dryer will not start at all; display may light up but pressing start does nothing and no code appears
Start Circuit / Door Interlock Issue
Symptom
Heat pump dryer runs but energy consumption is unusually high and drying is slow
Heat Pump Efficiency Loss
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E01 |
Dryer will not start, display shows E01 immediately after pressing start
|
Door Lock / Door Switch Fault | View Details |
| E02 |
Dryer stops shortly after starting, E02 displayed, sometimes with beeping
|
Overheating / Thermistor or NTC Sensor Fault | View Details |
| E03 |
Dryer stops mid-cycle, clothes still wet, E03 displayed
|
Moisture Sensor / Dryness Detection Fault | View Details |
| E04 |
Dryer does not heat, cycle ends quickly, E04 displayed
|
Heating Circuit Failure (Heater or Thermal Fuse) | View Details |
| E05 |
Dryer stops, E05 displayed, sometimes accompanied by unusual humming or no drum movement
|
Motor Start / Motor Overload Fault | View Details |
| E06 |
Dryer stops and displays E06, often early in the cycle, sometimes with no heat
|
Airflow / Exhaust System Fault | View Details |
| E07 |
Dryer shows E07 and will not start or stops shortly after starting
|
Water Tank Full / Condensate Pump Fault (Condenser & Heat Pump Models) | View Details |
| E08 |
Heat pump dryer shows E08, runs but does not dry properly, often with low or no heat
|
Heat Pump System Fault (Compressor / Refrigerant Circuit) | View Details |
| E09 |
Dryer displays E09 and will not start, sometimes after a power surge or outage
|
Main Control Board Communication / Internal Error | View Details |
| E10 |
Dryer shows E10, often related to sensor or configuration issues, may not start certain programs
|
Configuration / Program Parameter Error | View Details |
| E11 |
Dryer displays E11 and may stop heating or terminate cycle prematurely
|
Exhaust Temperature Too High / Safety Thermostat Tripped | View Details |
| E12 |
Dryer shows E12, often with poor drying performance and long cycle times
|
Inlet Air Temperature / Ambient Sensor Fault | View Details |
| E13 |
Dryer displays E13, may stop and beep, sometimes associated with water handling on condenser/heat pump models
|
Condensate Level / Overflow Protection Fault | View Details |
| E14 |
Dryer shows E14 and may not respond to button presses correctly
|
User Interface / Keypad Fault | View Details |
| E15 |
Dryer displays E15, may not start or may stop unexpectedly
|
Door Lock Circuit / Safety Interlock Error | View Details |
| E16 |
Dryer shows E16, often related to internal communication between boards
|
Communication Error Between Main Control and Sub-Board | View Details |
| E17 |
Dryer displays E17, may not heat correctly or may shut down
|
Humidity / Dryness Sensor Calibration Error | View Details |
| E18 |
Dryer shows E18, often with no drum rotation or erratic motor behavior
|
Motor Tachometer / Speed Sensor Fault | View Details |
| E19 |
Dryer displays E19, may not start or may shut down unexpectedly
|
Power Supply / Voltage Error | View Details |
| E20 |
Dryer shows E20, often with issues related to water handling on condenser/heat pump models
|
Condensate Pump Overload / Blockage | View Details |
| – |
Dryer control panel buttons are unresponsive or respond intermittently
|
User Interface / Touch Control Failure | View Details |
| – |
Dryer display and lights are dead; unit shows no signs of power
|
No Power / Main Supply or Fuse Issue | View Details |
| – |
Dryer display shows time remaining but the drum and motor do not run; only a faint click is heard
|
Motor Start Failure | View Details |
| – |
Dryer door will not open at the end of the cycle; door seems locked even though the machine is off
|
Door Lock Mechanism Stuck | View Details |
| – |
Dryer drum does not turn, but you can hear the motor humming or the dryer clicks and then stops
|
Broken or Slipped Drive Belt | View Details |
| – |
Dryer emits a burning smell or hot plastic odor during operation
|
Overheating / Lint or Object Contact with Heater | View Details |
| – |
Dryer interior light does not turn on when the door is opened, but dryer otherwise works
|
Drum Light Circuit Failure | View Details |
| – |
Dryer leaks water onto the floor during or after a cycle (condenser and heat pump models)
|
Condensate Drainage / Tank System Leak | View Details |
| – |
Dryer leaves a layer of lint on clothes or excessive lint in the drum after cycles
|
Lint Filtration / Airflow Issue | View Details |
| – |
Dryer makes loud squealing, screeching, or grinding noises during operation
|
Drum Support Roller / Bearing Wear | View Details |
| – |
Dryer produces a rattling or clinking noise, especially at low speeds
|
Foreign Objects in Drum or Blower | View Details |
| – |
Dryer runs but does not heat; clothes come out cold and wet, no error code displayed
|
Heating Element or Thermal Fuse Failure | View Details |
| – |
Dryer runs continuously and does not stop at the expected time; clothes may be over-dried
|
Moisture Sensor Not Detecting Dryness | View Details |
| – |
Dryer stops after a few minutes and clothes are still very wet, no error code shown
|
Overheating Protection Trip | View Details |
| – |
Dryer takes too long to dry or never fully dries clothes, but appears to heat normally
|
Restricted Airflow / Poor Ventilation | View Details |
| – |
Dryer vibrates excessively or thumps loudly, especially during start or with heavy loads
|
Drum Imbalance / Support Wear | View Details |
| – |
Dryer will not start at all; display may light up but pressing start does nothing and no code appears
|
Start Circuit / Door Interlock Issue | View Details |
| – |
Heat pump dryer runs but energy consumption is unusually high and drying is slow
|
Heat Pump Efficiency Loss | View Details |
No matching codes found